3D reconstruction of coronary stents in vivo based on motion compensated x-ray angiograms

被引:0
作者
Movassaghi, Babak
Schaefer, Dirk
Grass, Michael
Rasche, Volker
Wink, Onno
Garcia, Joel A.
Chen, James Y.
Messenger, John C.
Carroll, John D.
机构
[1] Philips Res N Amer, Briarcliff Manor, NY USA
[2] Philips Res Labs, Sector Tech Syst Hamburg, D-22335 Hamburg, Germany
[3] Univ Colorado, Hlth Sci Ctr, Div Cardiol, Denver, CO 80262 USA
来源
MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2006, PT 2 | 2006年 / 4191卷
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A new method is introduce for the three-dimensional (3D) reconstruction of the coronary stents in-vivo utilizing two-dimensional projection images acquired during rotational angiography (RA). The method is based on the application of motion compensated techniques to the acquired angiograms resulting in a temporal snapshot of the stent within the cardiac cycle. For the first time results of 3D reconstructed coronary stents in vivo, with high spatial resolution are presented. The proposed method allows for a comprehensive and unique quantitative 3D assessment of stent expansion that rivals current x-ray and intravascular ultrasound techniques.
引用
收藏
页码:177 / 184
页数:8
相关论文
共 17 条
[1]   3D tomographic reconstruction of coronary arteries using a precomputed 4D motion field [J].
Blondel, C ;
Vaillant, R ;
Malandain, G ;
Ayache, N .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (11) :2197-2208
[2]  
Blondel C, 2002, CARS 2002: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, P832
[3]  
DELACHARTRE P, 1999, IEEE INT ULTR S CAES
[4]   Patency of coronary artery lumen surrounded by metallic stent evaluated by three dimensional volume rendering images using ECG gated multislice computed tomography [J].
Funabashi, N ;
Komiyama, N ;
Komuro, I .
HEART, 2003, 89 (04) :388-388
[5]   Three-dimensional reconstruction of high contrast objects using C-arm image intensifier projection data [J].
Grass, M ;
Koppe, R ;
Klotz, E ;
Proksa, R ;
Kuhn, MH ;
Aerts, H ;
Op de Beek, J ;
Kemkers, R .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1999, 23 (06) :311-321
[6]  
KEATING TJ, 1975, PHOTOGRAMM ENG REM S, V41, P993
[7]  
Maintz D, 2003, INVEST RADIOL, V38, P790, DOI 10.1097/01.rli.0000086495.96457.54
[8]   Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation [J].
Maintz, D ;
Juergens, KU ;
Wichter, T ;
Grude, M ;
Heindel, W ;
Fischbach, R .
EUROPEAN RADIOLOGY, 2003, 13 (04) :830-835
[9]   Reconstruction of time-varying 3-D left-ventricular shape from multiview X-ray cineangiocardiograms [J].
Moriyama, M ;
Sato, Y ;
Naito, H ;
Hanayama, M ;
Ueguchi, T ;
Harada, T ;
Yoshimoto, F ;
Tamura, S .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (07) :773-785
[10]   3D coronary reconstruction from calibrated motion-compensated 2D projections based on semi-automated feature point detection [J].
Movassaghi, B ;
Rasche, V ;
Viergever, MA ;
Niessen, WJ .
MEDICAL IMAGING 2004: IMAGE PROCESSING, PTS 1-3, 2004, 5370 :1943-1950