Push-Pull mechanical ventilation system with heat exchanger controlled by intake air temperature

被引:2
|
作者
Fukushima, Akira [1 ]
Murata, Sayaka [2 ]
机构
[1] Hokkaido Univ Sience, Teineku Maeda 7-15-4-1, Sapporo, Hokkaido 0068585, Japan
[2] Northern Reg Bldg Res Inst, Asahikawa, Hokkaido 0788801, Japan
关键词
Push-pull mechanical ventilation system; Heat exchanger; Energy conservation; Supply only ventilation; Balance control;
D O I
10.1016/j.egypro.2015.11.112
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The purpose of this study is the development of a push-pull ventilation system, in which the air supply and exhaust amount is individually controlled by indoor and outdoor temperature difference, to maximize the ventilation performance and energy efficiency. By individually controlling the air flow rate of the supply and exhaust depending on the demand, the fan operating energy consumption is significantly reduced. High performance heat exchanger is also adopted. During non-heating period, it is possible to reduce indoor chemical contamination occurring with wall infiltration, by halving the amount of exhaust and pressurizing the room. (C) 2015 Published by Elsevier Ltd.
引用
收藏
页码:43 / 48
页数:6
相关论文
共 50 条
  • [1] Performance of a push air flow in the push-pull ventilation system
    Komine, H
    Mitsuda, K
    Tsuji, K
    PROGRESS IN MODERN VENTILATION, VOL 2, PROCEEDINGS, 2000, : 28 - 32
  • [2] Required performance of pushed air in push-pull ventilation system
    Komine, H
    Tsuji, K
    Mori, Y
    ADVANCES IN THE PREVENTION OF OCCUPATIONAL RESPIRATORY DISEASES, 1998, 1153 : 1120 - 1126
  • [3] PUSH-PULL VENTILATION SYSTEM FOR SWINE
    MUEHLING, AJ
    CHRISTIANSON, LL
    AGRICULTURAL ENGINEERING, VOLS 1-4: LAND AND WATER USE, AGRICULTURAL BUILDINGS, AGRICULTURAL MECHANISATION, POWER, PROCESSING AND SYSTEMS, 1989, : 1379 - 1384
  • [4] Numerical Analysis of Contaminant Controlled by Push-pull Ventilation
    Zheng, Wen-heng
    Liu, Jia-ping
    Wang, Yi
    Wang, Le
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 3814 - +
  • [5] DEVELOPMENT OF PUSH-PULL VENTILATION
    HUEBENER, DJ
    HUGHES, RT
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1985, 46 (05): : 262 - 267
  • [6] Appropriate flow rate for push-pull ventilation system
    Fukuhara, I
    Furuichi, T
    Tsuji, K
    PROGRESS IN MODERN VENTILATION, VOL 2, PROCEEDINGS, 2000, : 24 - 27
  • [7] COST ADVANTAGES OF PUSH-PULL VENTILATION
    PARKER, JH
    AIR ENGINEERING, 1967, 9 (07): : 26 - &
  • [8] Development of push-pull ventilation systems
    Olander, L
    PROGRESS IN MODERN VENTILATION, VOL 2, PROCEEDINGS, 2000, : 21 - 23
  • [9] Experiment and CFD on push-pull ventilation system in working spaces
    Wang, CB
    Kondo, Y
    Yoshino, H
    PROCEEDINGS OF THE 4TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS 1 AND 2, 2003, : 87 - 92
  • [10] Development of a push-pull ventilation system to control solder fume
    Watson, SI
    Cain, JR
    Cowie, H
    Cherrie, JW
    ANNALS OF OCCUPATIONAL HYGIENE, 2001, 45 (08): : 669 - 676