Improved functional vision with a modified prolate intraocular lens

被引:150
作者
Packer, M
Fine, IH
Hoffman, RS
Piers, PA
机构
[1] Oregon Eye Inst, Eugene, OR 97401 USA
[2] Oregon Hlth & Sci Univ, Portland, OR USA
[3] Pfizer, Groningen, Netherlands
关键词
D O I
10.1016/j.jcrs.2003.10.022
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate whether the Tecnis Z9000 intraocular lens (IOL) (Pfizer) with a modified prolate anterior surface provides better quality of vision than a conventional spherical IOL. Setting: Oregon Eye Institute, Eugene, Oregon, USA. Methods: Patients presenting for cataract surgery who were randomly assigned to receive a Tecnis Z9000 IOL (Pfizer) or a Sensar(R) OptiEdge AR40e IOL (AMO) in 1 eye were followed for 3 months postoperatively. The patient could elect to have the same type of IOL implanted in the fellow eye. The results of sine-wave grating contrast sensitivity testing under mesopic and photopic conditions were compared interindividually. Results: Monocular comparison was made between the 2 IOL groups, which comprised 15 patients each. The Tecnis IOL provided significantly better contrast sensitivity at 6 cycles per degree (cpd) under photopic conditions and at 1.5 and 3 cpd under mesopic conditions. Seven patients with a Tecnis IOL and 9 patients with an AR40e IOL had subsequent implantation in the fellow eye. In all eyes, including fellow eyes, having IOL implantation, the Tecnis provided significantly better contrast sensitivity at 3 and 6 cpd under photopic conditions and at 1.5, 3, and 6 cpd under mesopic conditions. The mean contrast sensitivity in fellow eyes showed that the Tecnis IOL produced significantly better results at some spatial frequencies. Conclusions: Results show the Tecnis IOL with a modified prolate anterior surface may produce better contrast sensitivity than a standard spherical IOL under mesopic and photopic conditions. Because contrast sensitivity testing correlates well with functional vision, a goal of future research should be to evaluate patient performance using functional tests such as driving simulation.
引用
收藏
页码:986 / 992
页数:7
相关论文
共 29 条
[21]   Ocular optical aberrometer for clinical use [J].
Mierdel, P ;
Kaemmerer, M ;
Mrochen, M ;
Krinke, HE ;
Seiler, T .
JOURNAL OF BIOMEDICAL OPTICS, 2001, 6 (02) :200-204
[22]  
MILLER G, 1992, BASIC CLIN SCI COURS, P84
[23]   Effect of chromatic aberration on contrast sensitivity in pseudophakic eyes [J].
Negishi, K ;
Ohnuma, K ;
Hirayama, N ;
Noda, T .
ARCHIVES OF OPHTHALMOLOGY, 2001, 119 (08) :1154-1158
[24]   CONTRAST SENSITIVITY THROUGHOUT ADULTHOOD [J].
OWSLEY, C ;
SEKULER, R ;
SIEMSEN, D .
VISION RESEARCH, 1983, 23 (07) :689-699
[25]  
Packer M, 2002, J REFRACT SURG, V18, P692
[26]   Impairment of mesopic vision by photorefractive keratectomy of myopia [J].
Schlote, T ;
Derse, M ;
Wannke, B ;
Bende, T ;
Jean, B .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1999, 214 (03) :136-141
[27]   Theoretical limits to visual performance [J].
Schwiegerling, J .
SURVEY OF OPHTHALMOLOGY, 2000, 45 (02) :139-146
[28]   Ocular optical aberrations after photorefractive keratectomy for myopia and myopic astigmatism [J].
Seiler, T ;
Kaemmerer, M ;
Mierdel, P ;
Krinke, HE .
ARCHIVES OF OPHTHALMOLOGY, 2000, 118 (01) :17-21
[29]   EFFECTS OF MONOCHROMATIC AND CHROMATIC OBLIQUE ABERRATIONS ON VISUAL PERFORMANCE DURING SPECTACLE LENS WEAR [J].
TANG, CY ;
CHARMAN, WN .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1992, 12 (03) :340-349