Improved functional vision with a modified prolate intraocular lens

被引:150
作者
Packer, M
Fine, IH
Hoffman, RS
Piers, PA
机构
[1] Oregon Eye Inst, Eugene, OR 97401 USA
[2] Oregon Hlth & Sci Univ, Portland, OR USA
[3] Pfizer, Groningen, Netherlands
关键词
D O I
10.1016/j.jcrs.2003.10.022
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate whether the Tecnis Z9000 intraocular lens (IOL) (Pfizer) with a modified prolate anterior surface provides better quality of vision than a conventional spherical IOL. Setting: Oregon Eye Institute, Eugene, Oregon, USA. Methods: Patients presenting for cataract surgery who were randomly assigned to receive a Tecnis Z9000 IOL (Pfizer) or a Sensar(R) OptiEdge AR40e IOL (AMO) in 1 eye were followed for 3 months postoperatively. The patient could elect to have the same type of IOL implanted in the fellow eye. The results of sine-wave grating contrast sensitivity testing under mesopic and photopic conditions were compared interindividually. Results: Monocular comparison was made between the 2 IOL groups, which comprised 15 patients each. The Tecnis IOL provided significantly better contrast sensitivity at 6 cycles per degree (cpd) under photopic conditions and at 1.5 and 3 cpd under mesopic conditions. Seven patients with a Tecnis IOL and 9 patients with an AR40e IOL had subsequent implantation in the fellow eye. In all eyes, including fellow eyes, having IOL implantation, the Tecnis provided significantly better contrast sensitivity at 3 and 6 cpd under photopic conditions and at 1.5, 3, and 6 cpd under mesopic conditions. The mean contrast sensitivity in fellow eyes showed that the Tecnis IOL produced significantly better results at some spatial frequencies. Conclusions: Results show the Tecnis IOL with a modified prolate anterior surface may produce better contrast sensitivity than a standard spherical IOL under mesopic and photopic conditions. Because contrast sensitivity testing correlates well with functional vision, a goal of future research should be to evaluate patient performance using functional tests such as driving simulation.
引用
收藏
页码:986 / 992
页数:7
相关论文
共 29 条
[1]  
Applegate RA, 2000, J REFRACT SURG, V16, P507
[2]   Corneal aberrations and visual performance after radial keratotomy [J].
Applegate, RA ;
Howland, HC ;
Sharp, RP ;
Cottingham, AJ ;
Yee, RW .
JOURNAL OF REFRACTIVE SURGERY, 1998, 14 (04) :397-407
[3]   Contribution of the cornea and internal surfaces to the change of ocular aberrations with age [J].
Artal, P ;
Berrio, E ;
Guirao, A .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2002, 19 (01) :137-143
[4]   EFFECTS OF AGING IN RETINAL IMAGE QUALITY [J].
ARTAL, P ;
FERRO, M ;
MIRANDA, I ;
NAVARRO, R .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1993, 10 (07) :1656-1662
[5]   OPTICAL AND RETINAL FACTORS AFFECTING VISUAL RESOLUTION [J].
CAMPBELL, FW ;
GREEN, DG .
JOURNAL OF PHYSIOLOGY-LONDON, 1965, 181 (03) :576-+
[6]   The shape of the aging human lens: curvature, equivalent refractive index and the lens paradox [J].
Dubbelman, M ;
Van der Heijde, GL .
VISION RESEARCH, 2001, 41 (14) :1867-1877
[7]   CONTRAST SENSITIVITY PREDICTS AGE-RELATED DIFFERENCES IN HIGHWAY-SIGN DISCRIMINABILITY [J].
EVANS, DW ;
GINSBURG, AP .
HUMAN FACTORS, 1985, 27 (06) :637-642
[8]   Use of power modulations in phacoemulsification - Choo-choo chop and flip phacoemulsification [J].
Fine, IH ;
Packer, M ;
Hoffman, RS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (02) :188-197
[9]  
GINSBURG AP, 1982, AM J OPTOM PHYS OPT, V59, P105
[10]  
GINSBURG AP, 1986, HDB PERCEPTION HUMAN, V2, pCH2