Improved sample preparation to determine acrylamide in difficult matrixes such as chocolate powder, cocoa, and coffee by liquid chromatography tandem mass spectroscopy

被引:100
|
作者
Delatour, T [1 ]
Périsset, A [1 ]
Goldmann, T [1 ]
Riediker, S [1 ]
Stadler, RH [1 ]
机构
[1] Nestec Ltd, Nestle Res Ctr, CH-1000 Lausanne 26, Switzerland
关键词
acrylamide; analysis; liquid-liquid extraction; LC-MS/MS; cocoa; chocolate; coffee; chicory; proficiency testing;
D O I
10.1021/jf0498362
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
An improved sample preparation (extraction and cleanup) is presented that enables the quantification of low levels of acrylamide in difficult matrixes, including soluble chocolate powder, cocoa, coffee, and coffee surrogate. Final analysis is done by isotope-dilution liquid chromatography-electrospray ionization tandem mass spectrometry (LC-MS/MS) using d(3)-acrylamide as internal standard. Sample pretreatment essentially encompasses (a) protein precipitation with Carrez I and II solutions, (b) extraction of the analyte into ethyl acetate, and (c) solid-phase extraction on a Multimode cartridge. The stability of acrylamide in final extracts and in certain commercial foods and beverages is also reported. This approach provided good performance in terms of linearity, accuracy and precision. Full validation was conducted in soluble chocolate powder, achieving a decision limit (CCalpha) and detection capability (CCbeta) of 9.2 and 12.5 mug/kg, respectively. The method was extended to the analysis of acrylamide in various foodstuffs such as mashed potatoes, crisp bread, and butter biscuit and cookies. Furthermore, the accuracy of the method is demonstrated by the results obtained in three inter-laboratory proficiency tests.
引用
收藏
页码:4625 / 4631
页数:7
相关论文
共 50 条
  • [1] Analysis of acrylamide in coffee and cocoa by isotope dilution liquid chromatography–tandem mass spectrometry
    Patricia C. Aguas
    Matthew J. Fitzhenry
    Georgina Giannikopoulos
    Peter Varelis
    Analytical and Bioanalytical Chemistry, 2006, 385 : 1526 - 1531
  • [2] Analysis of acrylamide in coffee and cocoa by isotope dilution liquid chromatography-tandem mass spectrometry
    Aguas, Patricia C.
    Fitzhenry, Matthew J.
    Giannikopoulos, Georgina
    Varelis, Peter
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 385 (08) : 1526 - 1531
  • [3] Determination of acrylamide in coffee and chocolate by pressurised fluid extraction and liquid chromatography-tandem mass spectrometry
    Pardo, O.
    Yusa, V.
    Coscolla, C.
    Leon, N.
    Pastor, A.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2007, 24 (07): : 663 - 672
  • [4] Supported liquid extraction offers improved sample preparation for aldosterone analysis by liquid chromatography tandem mass spectrometry
    Van Der Gugten, Jessica Grace
    Crawford, Matthew
    Grant, Russell P.
    Holmes, Daniel T.
    JOURNAL OF CLINICAL PATHOLOGY, 2012, 65 (11) : 1045 - 1047
  • [5] Sensitive isotope dilution liquid chromatography/electrospray ionization tandem mass spectrometry method for the determination of acrylamide in chocolate
    Ren, YP
    Zhang, Y
    Jiao, JJ
    Cai, ZX
    Zhang, Y
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2006, 23 (03): : 228 - 236
  • [6] Study of acrylamide in coffee using an improved liquid chromatography mass spectrometry method:: Investigation of colour changes and acrylamide formation in coffee during roasting
    Senyuva, HZS
    Gökmen, V
    FOOD ADDITIVES AND CONTAMINANTS, 2005, 22 (03): : 214 - 220
  • [7] Determination of acrylamide in infant formula milk powder by ultraperformance liquid chromatography-tandem mass spectrometry
    Li, Ying Crystal
    Zhao, Tieying
    He, Qiang
    Li, Zihao
    Chinese Journal of Analysis Laboratory, 2023, 42 (06) : 796 - 799
  • [8] Determination of Residual Acrylamide in Medical Polyacrylamide Hydrogel by High Performance Liquid Chromatography tandem Mass Spectroscopy
    Li, Wei-Wei
    Li, Hui
    Liu, Zhi-Fei
    Qiao, Qun
    BIOMEDICAL AND ENVIRONMENTAL SCIENCES, 2009, 22 (01) : 28 - 31
  • [9] Determination of Residual Acrylamide in Medical Polyacrylamide Hydrogel by High Performance Liquid Chromatography tandem Mass Spectroscopy
    WEI-WEI LI~*
    ~(**)Department ofEcsomatics
    BiomedicalandEnvironmentalSciences, 2009, 22 (01) : 28 - 31
  • [10] Recent trends in sample preparation and liquid chromatography/mass spectrometry for pesticide residue analysis in food and related matrixes
    20154801603968
    Rejczak, Tomasz (tomasz.tuzimski@umlub.pl), 1600, AOAC International (98):