Doping inorganic ions to regulate bioactivity of Ca-P coating on bioabsorbable high purity magnesium

被引:6
作者
Wu, Hongliu [1 ]
Zhang, Ruopeng [1 ]
Li, Xiao [1 ]
Ni, Jiahua [1 ]
Zhao, Changli [1 ]
Song, Yang [2 ]
Wang, Jiawei [1 ]
Zhang, Shaoxiang [3 ]
Zheng, Yufeng [4 ]
Zhang, Xiaonong [1 ,3 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Mat Sci & Engn, State Key Lab Met Matrix Composites, Shanghai 200240, Peoples R China
[2] Univ Hong Kong, Dept Mech Engn, Hong Kong, Hong Kong, Peoples R China
[3] Suzhou Origin Med Technol Co, Suzhou 215513, Jiangsu, Peoples R China
[4] Peking Univ, Coll Engn, Dept Mat Sci & Engn, State Key Lab Turbulence & Complex Syst, Beijing 100871, Peoples R China
基金
中国国家自然科学基金;
关键词
Calcium phosphate coaling; Adjustable bioactivity; Magnesium; Biomimelic depoition; In vitro; MG-ZN ALLOY; VASCULAR CALCIFICATION; EMERGING ROLE; PHOSPHATE; ELECTRODEPOSITION; BIOMATERIALS; CORROSION; IMPLANT; CELLS;
D O I
10.1016/j.pnsc.2014.08.004
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Performance of biomaterials was strongly affected by their sun ace properties and could he designed artificially to meet specific biomedical requirements. In this study, F-(F), SiO42-(Si), or HCO3-(C)-doped Ca-P coatings were fabricated by biomimetic deposition on the surface of biodegradable high-purity magnesium (HP Mg). The crystalline phases, morphologies and compositions of Ca-P coatings had been characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM) and energy-dispersive spectroscopy (EDS). The biomineralization and corrosion resistance of doped Ca-P coatings had also been investigated. The results showed that the Ca-P coating with or without doped elements mainly contained the plate-like dicalcium phosphate dehydrate (DCPD) phase. The doped F, Si, or C changed the surface morphology of Ca-P coatings after mineralization. Doped F enhanced the mineralization of Ca-P coating, and doped Si retarded the mineralization of Ca-P coating. However, H-2 evolution of HP Mg discs with different Ca-P coatings was close to 0.4-0.7 ml/cm(2) after two-week immersion. That meant that the corrosion resistance of the Ca-P coatings with different or without doped elements did not change significantly. (C) 2014 Chinese Materials Research Society. Production and hosting by Elsevier B.V. All rights reserved.
引用
收藏
页码:479 / 485
页数:7
相关论文
共 22 条
[1]   Can bioactivity be tested in vitro with SBF solution? [J].
Bohner, Marc ;
Lemaitre, Jacques .
BIOMATERIALS, 2009, 30 (12) :2175-2179
[2]   Interaction between a high purity magnesium surface and PCL and PLA coatings during dynamic degradation [J].
Chen, Ying ;
Song, Yang ;
Zhang, Shaoxiang ;
Li, Jianan ;
Zhao, Changli ;
Zhang, Xiaonong .
BIOMEDICAL MATERIALS, 2011, 6 (02)
[3]   The emerging role of phosphate in vascular calcification [J].
Giachelli, Cecilia M. .
KIDNEY INTERNATIONAL, 2009, 75 (09) :890-897
[4]   Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology? [J].
Heublein, B ;
Rohde, R ;
Kaese, V ;
Niemeyer, M ;
Hartung, W ;
Haverich, A .
HEART, 2003, 89 (06) :651-656
[5]   Phosphate and vascular calcification: Emerging role of the sodium-dependent phosphate co-transporter PiT-1 [J].
Lau, Wei Ling ;
Festing, Maria H. ;
Giachelli, Cecilia M. .
THROMBOSIS AND HAEMOSTASIS, 2010, 104 (03) :464-470
[6]  
LeGeros RZ, 2002, CLIN ORTHOP RELAT R, P81
[7]   Design of a pseudo-physiological test bench specific to the development of biodegradable metallic biomaterials [J].
Levesque, Julie ;
Hermawan, Hendra ;
Dube, Dominique ;
Mantovani, Diego .
ACTA BIOMATERIALIA, 2008, 4 (02) :284-295
[8]   In vitro responses of human bone marrow stromal cells to a fluoridated hydroxyapatite coated biodegradable Mg-Zn alloy [J].
Li, Jianan ;
Song, Yang ;
Zhang, Shaoxiang ;
Zhao, Changli ;
Zhang, Fan ;
Zhang, Xiaonong ;
Cao, Lei ;
Fan, Qiming ;
Tang, Tingting .
BIOMATERIALS, 2010, 31 (22) :5782-5788
[9]   Corrosion resistance and cytotoxicity of a MgF2 coating on biomedical Mg-1Ca alloy via vacuum evaporation deposition method [J].
Li, N. ;
Li, Y. D. ;
Wang, Y. B. ;
Li, M. ;
Cheng, Y. ;
Wu, Y. H. ;
Zheng, Y. F. .
SURFACE AND INTERFACE ANALYSIS, 2013, 45 (08) :1217-1222
[10]   Effect of electrodeposition modes on surface characteristics and corrosion properties of fluorine-doped hydroxyapatite coatings on Mg-Zn-Ca alloy [J].
Meng, E. C. ;
Guan, S. K. ;
Wang, H. X. ;
Wang, L. G. ;
Zhu, S. J. ;
Hu, J. H. ;
Ren, C. X. ;
Gao, J. H. ;
Feng, Y. S. .
APPLIED SURFACE SCIENCE, 2011, 257 (11) :4811-4816