Determination of sub-ppb epichlorohydrin levels in water by on-line solid-phase extraction liquid chromatography/tandem mass spectrometry

被引:6
作者
Ripolles, Cristina [1 ]
Marin, Jose M. [1 ]
Lopez, Francisco J. [1 ]
Sancho, Juan V. [1 ]
Hernandez, Felix [1 ]
机构
[1] Univ Jaume 1, Res Inst Pesticides & Water, E-12071 Castellon de La Plana, Spain
关键词
GAS-CHROMATOGRAPHY; WASTE-WATER; SURFACE-WATER; TRANSFORMATION PRODUCTS; EMERGING CONTAMINANTS; ION CHROMATOGRAPHY; LC-MS/MS; PESTICIDES; MICROEXTRACTION; SAMPLES;
D O I
10.1002/rcm.4082
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new sensitive and selective method based on on-line solid-phase extraction (SPE) coupled to liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) using a triple quadrupole mass spectrometer has been developed for the determination of epichlorohydrin (ECH) in different types of water samples. ECH is not easily determined directly by ESI-MS as it is not readily ionized, and it has a low molecular mass and high polarity. Thus, prior derivatization of ECH was necessary, employing 3,5-difluorobenzylamine as a derivatizing agent with FeQ(III) as a catalyst. In order to achieve accurate quantification, correcting for matrix effects, losses in the derivatization process and instrumental deviations, isotope labelled ECH (ECH-d(5)) was added as an internal standard (IS) to the water samples. The method was validated based on European SANCO guidelines using drinking and other types of treated water spiked at two concentration levels (0.1 and 1.0 mu g/L), the lower level having been established as the limit of quantification (LOQ) of the method. Satisfactory accuracy (recoveries between 70 and 103%), precision (RSD <20%) and linearity (from 0.05 to 50 mu g/L, r >0.99) were obtained. The limit of detection (LOD) was set up at 0.03 mu g/L. The method was applied to different water samples (drinking water and water samples collected from a municipal treatment water plant). In order to enhance confidence, five selected reaction monitoring (SRM) transitions were acquired, thus obtaining a simultaneous reliable quantification and identification of ECH in water, even at sub-ppb levels. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:1841 / 1848
页数:8
相关论文
共 30 条
[1]   Simultaneous ultra-high-pressure liquid chromatography-tandem mass spectrometry determination of amphetamine and amphetamine-like stimulants, cocaine and its metabolites, and a cannabis metabolite in surface water and urban wastewater [J].
Bijlsma, Lubertus ;
Sancho, Juan V. ;
Pitarch, Elena ;
Ibanez, Maria ;
Hernandez, Felix .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (15) :3078-3089
[2]   Determination of epichlorohydrin by sulfite derivatization and ion chromatography: characterization of the sulfite derivatives by ion chromatography-mass spectrometry [J].
Bruzzoniti, MC ;
Andrensek, S ;
Novic, M ;
Perrachon, D ;
Sarzanini, C .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1034 (1-2) :243-247
[3]   Mass spectrometric analysis of illicit drugs in wastewater and surface water [J].
Castiglioni, Sara ;
Zuccato, Ettore ;
Chiabrando, Chiara ;
Fanelli, Roberto ;
Bagnati, Renzo .
MASS SPECTROMETRY REVIEWS, 2008, 27 (04) :378-394
[4]   Simultaneous analysis of 23 priority volatile compounds in water by solid-phase microextraction-gas chromatography-mass spectrometry and estimation of the method's uncertainty [J].
Dias Guimaraes, Ana ;
Joao Carvalho, Jose ;
Goncalves, Carlos ;
de Fatima Alpendurada, Maria .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2008, 88 (03) :151-164
[5]   Determination of epichlorohydrin in water and sewage samples [J].
Gaca, Jerzy ;
Wejnerowska, Grazyna .
TALANTA, 2006, 70 (05) :1044-1050
[6]   Fast multiresidue screening of 300 pesticides in water for human consumption by LC-MS/MS [J].
Greulich, Kerstin ;
Alder, Lutz .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (01) :183-197
[7]   Strategies for quantification and confirmation of multi-class polar pesticides and transformation products in water by LC-MS2 using triple quadrupole and hybrid quadrupole time-of-flight analyzers [J].
Hernández, F ;
Pozo, OJ ;
Sancho, JV ;
López, FJ ;
Marín, JM ;
Ibáñez, M .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (07) :596-612
[8]   Re-evaluation of glyphosate determination in water by liquid chromatography coupled to electrospray tandem mass spectrometry [J].
Ibanez, Maria ;
Pozo, Oscar J. ;
Sancho, Juan V. ;
Lopez, Francisco J. ;
Hernandez, Felix .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1134 (1-2) :51-55
[9]  
*INT AG RES CANC, 1999, MON VAL CARC RISK HU, V71, P603
[10]   Aqueous-phase aminolysis: Approach for the analysis of epoxides in water [J].
Khan, SJ ;
Weinberg, HS ;
Bedford, EC .
ANALYTICAL CHEMISTRY, 2006, 78 (08) :2608-2616