Determination of sub-ppb epichlorohydrin levels in water by on-line solid-phase extraction liquid chromatography/tandem mass spectrometry

被引:6
|
作者
Ripolles, Cristina [1 ]
Marin, Jose M. [1 ]
Lopez, Francisco J. [1 ]
Sancho, Juan V. [1 ]
Hernandez, Felix [1 ]
机构
[1] Univ Jaume 1, Res Inst Pesticides & Water, E-12071 Castellon de La Plana, Spain
关键词
GAS-CHROMATOGRAPHY; WASTE-WATER; SURFACE-WATER; TRANSFORMATION PRODUCTS; EMERGING CONTAMINANTS; ION CHROMATOGRAPHY; LC-MS/MS; PESTICIDES; MICROEXTRACTION; SAMPLES;
D O I
10.1002/rcm.4082
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new sensitive and selective method based on on-line solid-phase extraction (SPE) coupled to liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) using a triple quadrupole mass spectrometer has been developed for the determination of epichlorohydrin (ECH) in different types of water samples. ECH is not easily determined directly by ESI-MS as it is not readily ionized, and it has a low molecular mass and high polarity. Thus, prior derivatization of ECH was necessary, employing 3,5-difluorobenzylamine as a derivatizing agent with FeQ(III) as a catalyst. In order to achieve accurate quantification, correcting for matrix effects, losses in the derivatization process and instrumental deviations, isotope labelled ECH (ECH-d(5)) was added as an internal standard (IS) to the water samples. The method was validated based on European SANCO guidelines using drinking and other types of treated water spiked at two concentration levels (0.1 and 1.0 mu g/L), the lower level having been established as the limit of quantification (LOQ) of the method. Satisfactory accuracy (recoveries between 70 and 103%), precision (RSD <20%) and linearity (from 0.05 to 50 mu g/L, r >0.99) were obtained. The limit of detection (LOD) was set up at 0.03 mu g/L. The method was applied to different water samples (drinking water and water samples collected from a municipal treatment water plant). In order to enhance confidence, five selected reaction monitoring (SRM) transitions were acquired, thus obtaining a simultaneous reliable quantification and identification of ECH in water, even at sub-ppb levels. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:1841 / 1848
页数:8
相关论文
共 50 条
  • [1] Electrospray ion chromatography tandem mass spectrometry of bromate at sub-ppb levels in water
    Charles, L
    Pepin, D
    Casetta, B
    ANALYTICAL CHEMISTRY, 1996, 68 (15) : 2554 - 2558
  • [2] On-line coupling of solid-phase extraction to liquid chromatography-tandem mass spectrometry for the determination of macrolide antibiotics in environmental water
    Ding, Jie
    Ren, Nanqi
    Chen, Ligang
    Ding, Lan
    ANALYTICA CHIMICA ACTA, 2009, 634 (02) : 215 - 221
  • [3] Determination of pesticide residues in wine by solid-phase extraction on-line combined with liquid chromatography tandem mass spectrometry
    Perez-Mayan, L.
    Ramil, M.
    Cela, R.
    Rodriguez, I.
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2021, 104
  • [4] Determination of Sub-ppb Cadmium in Urine by Solid-Phase Extraction and Inductively Coupled Plasma–Mass Spectrometry
    Yoshihiro Suzuki
    Yoko Endo
    Masanori Ogawa
    Michiko Matsuda
    Yoshiaki Nakajima
    Nobuhiko Onda
    Motoki Iwasaki
    Shoichiro Tsugane
    Analytical Sciences, 2008, 24 : 1049 - 1052
  • [5] Electrospray ion chromatography-tandem mass spectrometry of bromate at sub-ppb levels in water
    Inst Louise Blanquet and Chaire, d'Hydrologie et Hygiene, Clermont-Ferrand, France
    Int J Comput Vision, 3 (2554-2558):
  • [6] Electrospray ion chromatography tandem mass spectrometry of oxyhalides at sub-ppb levels
    Charles, L
    Pépin, D
    ANALYTICAL CHEMISTRY, 1998, 70 (02) : 353 - 359
  • [7] Determination of itraconazole and hydroxyitraconazole in plasma by use of liquid chromatography-tandem mass spectrometry with on-line solid-phase extraction
    Vogeser, M
    Spöhrer, U
    Schiel, X
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2003, 41 (07) : 915 - 920
  • [8] On-line Solid-Phase Extraction Coupled to Liquid Chromatography–Ion Trap Tandem Mass Spectrometry for Determination of Penicillins in Catfish
    Luana Maggi
    Jorge Hurtado de Mendoza
    Amaya Zalacain
    Liliana Bonetto
    Francisco A. Mocholí
    Manuel Carmona
    Food Analytical Methods, 2012, 5 : 1047 - 1053
  • [9] Determination of sub-ppb cadmium in urine by solid-phase extraction and inductively coupled plasma-mass spectrometry
    Suzuki, Yoshihiro
    Endo, Yoko
    Ogawa, Masanori
    Matsuda, Michiko
    Nakajima, Yoshiaki
    Onda, Nobuhiko
    Iwasaki, Motoki
    Tsugane, Shoichiro
    ANALYTICAL SCIENCES, 2008, 24 (08) : 1049 - 1052
  • [10] Quantification of sirolimus by liquid chromatography-tandem mass spectrometry using on-line solid-phase extraction
    Vogeser, M
    Fleischer, C
    Meiser, B
    Groetzner, J
    Spöhrer, U
    Seidel, D
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2002, 40 (01) : 40 - 45