Trace analysis of chlorobenzenes in water samples using headspace solvent microextraction and gas chromatography/electron capture detection

被引:50
作者
Khajeh, Mostafa [1 ]
Yamini, Yadollah [1 ]
Hassan, Mal [1 ]
机构
[1] Tarbiat Modarres Univ, Dept Chem, Tehran, Iran
关键词
headspace solvent microextraction; chlorobenzenes; gas chromatography;
D O I
10.1016/j.talanta.2005.12.020
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present work, a rapid method for the extraction and determination of chlorobenzenes (CBs) such as monochlorobenzene, 1,2-dichlorobenzene, 1,3-dichlorobenzene, 1,4-dichlorobenzene, 1,2,3-trichlorobenzene and 1,2,4-trichlorobenzene in water samples using the headspace solvent microextraction (HSME) and gas chromatography/electron capture detector (ECD) has been described. A microdrop of the dodecane containing monobromobenzene (internal standard) was used as extracting solvent in this investigation. The analytes were extracted by suspending a 2.5 mu l extraction drop directly from the tip of a microsyringe fixed above an extraction vial with a septum in a way that the needle passed through the septum and the needle tip appeared above the surface of the solution. After the extraction was finished, the drop was retracted back into the needle and injected directly into a GC column. Optimization of experimental conditions such as nature of the extracting solvent, microdrop and sample temperatures, stirring rate, microdrop and sample volumes, the ionic strength and extraction time were investigated. The optimized conditions were as follows: dodecane as the extracting solvent, the extraction temperature, 45 degrees C; the sodium chloride concentration, 2 M; the extraction time, 5.0 min; the stirring rate, 500 rpm; the drop volume, 2.5 mu l; the sample volume, 7 ml; the microsyringe needle temperature, 0.0 degrees C. The limit of detection (LOD) ranged from 0.1 mu g/l (for 1,3-dichlorobenzene) to 3.0 mu g/l (for 1,4-dichlorobenzene) and linear range of 0.5-3.0 mu g/l for 1,2-dichlorobenzene, 1,3-dichlorobenzene and from 5.0 to 20.0 mu g/l for monochlorobenzene and from 5.0 to 30 mu g/l for 1,4-dichlorobenzene. The relative standard deviations (R.S.D.) for most of CBs at the 5 mu g/l level were below 10%. The optimized procedure was successfully applied to the extraction and determination of CBs in different water samples. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:1088 / 1094
页数:7
相关论文
共 26 条
[1]  
APENDURADA MD, 2000, J CHROMATOGR A, V889, P3
[2]   DECHLORINATION OF CHLORINATED BENZENES BY AN ANAEROBIC MICROBIAL CONSORTIUM THAT SELECTIVELY MEDIATES THE THERMODYNAMIC MOST FAVORABLE REACTIONS [J].
BEURSKENS, JEM ;
DEKKER, CGC ;
VANDENHEUVEL, H ;
SWART, M ;
DEWOLF, J ;
DOLFING, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1994, 28 (04) :701-706
[3]   Development of fluorinated low temperature glassy carbon films for solid-phase microextraction [J].
Giardina, M ;
Ding, LH ;
Olesik, SV .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1060 (1-2) :215-224
[4]   Trace analysis of ten chlorinated benzenes in water by headspace solid-phase microextraction [J].
He, Y ;
Wang, Y ;
Lee, HK .
JOURNAL OF CHROMATOGRAPHY A, 2000, 874 (01) :149-154
[5]   Liquid phase microextraction in a single drop of organic solvent by using a conventional microsyringe [J].
He, Y ;
Lee, HK .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4634-4640
[6]   Mass transfer characteristics of solvent extraction into a single drop at the tip of a syringe needle [J].
Jeannot, MA ;
Cantwell, FF .
ANALYTICAL CHEMISTRY, 1997, 69 (02) :235-239
[7]  
Karnofsky B., 1997, HAZARDOUS WASTE MANA
[8]   Headspace microdrop analysis - an alternative test method for gasoline diluent and benzene, toluene, ethylbenzene and xylenes in used engine oils [J].
Kokosa, JM ;
Przyjazny, A .
JOURNAL OF CHROMATOGRAPHY A, 2003, 983 (1-2) :205-214
[9]   Baseline toxicity of a chlorobenzene mixture and total body residues measured and estimated with solid-phase microextraction [J].
Leslie, HA ;
Hermens, JLM ;
Kraak, MHS .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2004, 23 (08) :2017-2021
[10]   Gas chromatographic-mass spectrometric analysis of dichlorobenzene isomers in human blood with headspace solid-phase microextraction [J].
Liu, JT ;
Hara, K ;
Kashimura, S ;
Hamanaka, T ;
Tomojiri, S ;
Tanaka, K .
JOURNAL OF CHROMATOGRAPHY B, 1999, 731 (02) :217-221