Multicenter clinical experience using an Erbium:YAG laser for vitreoretinal surgery

被引:49
作者
DAmico, DJ
Blumenkranz, MS
Lavin, MJ
QuirozMercado, H
Pallikaris, IG
Marcellino, GR
Brooks, GE
机构
[1] STANFORD UNIV,MED CTR,DEPT OPHTHALMOL,PALO ALTO,CA 94304
[2] UNIV MANCHESTER,SCH MED,MANCHESTER ROYAL EYE HOSP,DEPT OPHTHALMOL,MANCHESTER,LANCS,ENGLAND
[3] HOSP ASOCIAC EVITAR LA CEGUERA MEXICO,MEXICO CITY,DF,MEXICO
[4] UNIV CRETE,VARDINOYIANN EYE INST,IRAKLION,CRETE,GREECE
[5] COHERENT MED INC,PALO ALTO,CA
关键词
D O I
10.1016/S0161-6420(96)30460-0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the advantages, disadvantages, safety, complications, and surgical applicability of an erbium:YAG laser system for maneuvers in vitreoretinal surgery. Methods: A prospective, consecutive trial of 68 eyes in 66 patients undergoing vitreoretinal surgery in which an erbium:YAG laser with graduated output from 0.2 to 5.0 mJ per pulse, repetition rate of 2 to 30 Hz, and equipped with a flexible fiber optic and interchangeable 20-gauge intraocular fiber optic endoprobes was used to perform specific maneuvers, including transection, incision, and ablation of membranes, retinotomy, vessel coagulation, iridectomy, and lens tissue ablation. The patients were treated in five centers in contemporary vitreoretinal surgical settings for surgical indications, including proliferative diabetic retinopathy, proliferative vitreoretinopathy, epiretinal membrane, and retinopathy of prematurity. Results: One hundred seventy-four maneuvers were performed with an overall surgical efficacy rating of excellent or good in 84% of maneuvers, ranging from a high of 100% for subretinal membrane transection to a low of 25% for coagulation of blood vessels. Complications included retinal break or photocoagulative injury in 5% of epiretinal membrane incisions, minor bleeding from transected retinal vessels during 29% of retinotomies, and intraocular lens damage during two posterior capsulotomies. The most significant limitation was the cautious pace used during maneuvers near the retinal surface. Conclusion: The erbium:YAG laser is capable of versatile new approaches offering precise tissue cutting and ablation in vitreoretinal surgical maneuvers with a high degree of safety. The main limitation encountered was the slow speed of certain critical maneuvers near the retina.
引用
收藏
页码:1575 / 1585
页数:11
相关论文
共 17 条
[1]   TANGENTIAL CORNEAL SURFACE ABLATION WITH 193-NM AND 308-NM EXCIMER AND 2936-NM ERBIUM-YAG LASER IRRADIATION [J].
BELGOROD, BM ;
EDIGER, MN ;
WEIBLINGER, RP ;
ERLANDSON, RA .
ARCHIVES OF OPHTHALMOLOGY, 1992, 110 (04) :533-536
[2]  
Bende T, 1991, Fortschr Ophthalmol, V88, P12
[3]  
BERGER JW, 1995, P SOC PHOTO-OPT INS, V2393, P148, DOI 10.1117/12.209840
[4]   ERBIUM-YAG LASER PHOTOTHERMAL RETINAL ABLATION IN ENUCLEATED RABBIT EYES [J].
DAMICO, DJ ;
MOULTON, RS ;
THEODOSSIADIS, PG ;
YARBOROUGH, JM .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1994, 117 (06) :783-790
[5]   Initial clinical experience with an erbium:YAG laser for vitreoretinal surgery [J].
DAmico, DJ ;
Brazitikos, PD ;
Marcellino, GR ;
Finn, SM ;
Hobart, JL .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1996, 121 (04) :414-425
[6]  
DAMICO DJ, 1995, OPHTHALMOLOGY, V102, P278
[7]   COMPARISON OF LASER PHACOVAPORIZATION USING THE ER-YAG AND THE ER-YSGG LASER [J].
GAILITIS, RP ;
PATTERSON, SW ;
SAMUELS, MA ;
HAGEN, K ;
REN, QS ;
WARING, GO .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (05) :697-700
[8]  
LIN CP, 1990, INVEST OPHTH VIS SCI, V31, P2546
[9]   ERBIUM-YAG LASER-SURGERY ON EXPERIMENTAL VITREOUS MEMBRANES [J].
MARGOLIS, TI ;
FARNATH, DA ;
DESTRO, M ;
PULIAFITO, CA .
ARCHIVES OF OPHTHALMOLOGY, 1989, 107 (03) :424-428
[10]  
OZLER SA, 1991, INVEST OPHTH VIS SCI, V32, P2498