Coefficient of variation: A powerful Doppler ultrasonographic parameter for detection of renal artery stenosis

被引:2
作者
Eibenberger, K
Schima, H
Trubel, W
Temel, T
Schmidt, C
Scherer, R
Windberger, U
Dock, W
Grabenwoger, F
机构
[1] UNIV VIENNA, CTR BIOMED RES, A-1090 VIENNA, AUSTRIA
[2] UNIV VIENNA, DEPT CARDIOTHORAC SURG, A-1090 VIENNA, AUSTRIA
关键词
renal arteries; stenosis; ultrasonography; Doppler studies; blood flow; dynamics; obstruction; renal artery;
D O I
10.7863/jum.1996.15.7.505
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The aim of our study was to objectively compare the effectiveness of various Doppler parameters in the diagnosis of renal artery stenosis. In three sheep, variable degrees of renal artery stenosis were induced and renal segmental arteries were investigated using pulsed Doppler sonography. In each animal the standard deviation of the instantaneous peak velocity within one cardiac cycle normalized by the mean peak velocity (coefficient of variation) had significantly higher normalized regression coefficients (k* = -0.215, average of three animals) when compared to resistive index (k* = -0.090) and acceleration index (k* = -0.069). In each individual animal, coefficient of variation detected lower pressure gradients (6.3 mm Hg, average value) than did resistive index (13.4 mm Hg) or accleration index (17.3 mm Hg). The coefficient of variation may detect the presence of pressure gradients in renal artery stenosis more accurately than acceleration index or resistive index.
引用
收藏
页码:505 / 512
页数:8
相关论文
共 48 条
[31]   Spiral CT quantification of aorto-renal calcification and its use in the detection of atheromatous renal artery stenosis: A study in 42 patients [J].
Pierre Gayard ;
Jean-Marc Garcier ;
Jean-Yves Boire ;
Anne Ravel ;
Nessim Perez ;
Christian Privat ;
Pascal Lucien ;
Jean-François Viallet ;
Louis Boyer .
CardioVascular and Interventional Radiology, 2000, 23 :17-21
[32]   Spiral CT quantification of aorto-renal calcification and its use in the detection of atheromatous renal artery stenosis: A study in 42 patients [J].
Gayard, P ;
Garcier, JM ;
Boire, JY ;
Ravel, A ;
Perez, N ;
Privat, C ;
Lucien, P ;
Viallet, JF ;
Boyer, L .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 23 (01) :17-21
[33]   Ultrasound as a first line screening tool for the detection of Renal Artery Stenosis: a comprehensive review [J].
Spyridopoulos, Themistoklis N. ;
Kaziani, Katerina ;
Balanika, Alexia P. ;
Kalokairinou-Motogna, Mariana ;
Bizimi, Vasiliki ;
Paianidi, Iovana ;
Baltas, Christos S. .
MEDICAL ULTRASONOGRAPHY, 2010, 12 (03) :228-232
[34]   Detection accuracy of various display modalities in CT angiography of renal artery stenosis. [J].
Galanski, M ;
Hoogestraat-Lufft, L ;
Högemann, D ;
Baus, S ;
Schmidt, A ;
Koehler, A ;
Arlart, IP ;
Landwehr, P ;
Huppert, P ;
Hecker, H ;
Chavan, A .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 171 (03) :200-206
[35]   DETECTION OF INTERNAL CAROTID-ARTERY STENOSIS - COMPARISON OF MR ANGIOGRAPHY, COLOR DOPPLER SONOGRAPHY, AND ARTERIOGRAPHY [J].
POLAK, JF ;
BAJAKIAN, RL ;
OLEARY, DH ;
ANDERSON, MR ;
DONALDSON, MC ;
JOLESZ, FA .
RADIOLOGY, 1992, 182 (01) :35-40
[36]   RENAL-ARTERY STENOSIS - EVALUATION OF DOPPLER US AFTER INHIBITION OF ANGIOTENSIN-CONVERTING ENZYME WITH CAPTOPRIL [J].
RENE, PC ;
OLIVA, VL ;
BUI, BT ;
FROMENT, D ;
HAREL, C ;
NICOLET, V ;
COURTEAU, M ;
CARIGNAN, L .
RADIOLOGY, 1995, 196 (03) :675-679
[37]   POSTTRANSPLANT RENAL-ARTERY STENOSIS - OUTPATIENT INTRAARTERIAL DSA VERSUS COLOR AIDED DUPLEX DOPPLER SONOGRAPHY [J].
DUDA, SH ;
ERLEY, CM ;
WAKAT, JP ;
HUPPERT, PE ;
LAUCHART, W ;
RISLER, T ;
CLAUSSEN, CD .
EUROPEAN JOURNAL OF RADIOLOGY, 1993, 16 (02) :95-101
[38]   Wall Shear Stress Measurement in Carotid Artery Phantoms with Variation in Degree of Stenosis Using Plane Wave Vector Doppler [J].
Yang, Ke ;
Hoskins, Peter R. ;
Corner, George A. ;
Xia, Chunming ;
Huang, Zhihong .
APPLIED SCIENCES-BASEL, 2023, 13 (01)
[39]   Value of Acceleration Flow in the Left Anterior Descending Coronary Artery for the Detection of Coronary Artery Stenosis by Transthoracic Coronary Color Doppler Echocardiography [J].
陈斌 ;
邓又斌 ;
杨好意 ;
阮燕菲 ;
常青 ;
毕小军 ;
王红英 .
华中科技大学学报(医学英德文版), 2005, (05) :597-600
[40]   Value of acceleration flow in the left anterior descending coronary artery for the detection of coronary artery stenosis by transthoracic coronary color doppler echocardiography [J].
Chen Bin ;
Deng Youbin ;
Yang Haoyi ;
Ruan Yanfei ;
Chang Qing ;
Bi Xiaojun ;
Wang Hongying .
Journal of Huazhong University of Science and Technology [Medical Sciences], 2005, 25 (5) :597-600