Fast simultaneous noncontrast angiography and intraplaque hemorrhage (fSNAP) sequence for carotid artery imaging

被引:11
作者
Chen, Shuo [1 ]
Ning, Jia [1 ]
Zhao, Xihai [1 ]
Wang, Jinnan [2 ]
Zhou, Zechen [1 ]
Yuan, Chun [1 ,3 ]
Chen, Huijun [1 ]
机构
[1] Tsinghua Univ, Sch Med, Dept Biomed Engn, Ctr Biomed Imaging Res, Beijing, Peoples R China
[2] Philips Res North Amer, Clin Sites Res Program, Briarcliff Manor, NY USA
[3] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
关键词
carotid artery; MR angiography; intraplaque hemorrhage; phase-sensitive; SNAP; SENSITIVE INVERSION-RECOVERY; MAGNETIC-RESONANCE; PHASE-CORRECTION; PLAQUE; MRI; RECONSTRUCTION; ASSOCIATION; RESOLUTION; CONTRAST; EVENTS;
D O I
10.1002/mrm.26111
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo propose a fast simultaneous noncontrast angiography and intraplaque hemorrhage (fSNAP) sequence for carotid artery imaging. MethodsThe proposed fSNAP sequence uses a low-resolution reference acquisition for phase-sensitive reconstruction to speed up the scan, and an inversion recovery acquisition with arbitrary k-space filling order to generate similar contrast to conventional SNAP. Four healthy volunteers and eight patients were recruited to test the performance of fSNAP in vivo. The lumen area quantification, muscle-blood CNR, IPH-blood CNR, lumen SNR, and standard deviation and intraplaque hemorrhage (IPH) detection accuracy were compared between fSNAP and SNAP. ResultsBy using a low-resolution reference acquisition with 1/4 matrix size of the full-resolution reference scan, the scan time of fSNAP was 37.5% less than that of SNAP. A high agreement of lumen area measurement (ICC=0.97, 95% CI: 0.96-0.99) and IPH detection (Kappa=1) were found between fSNAP and SNAP. Also, no significant difference was found for muscle-blood CNR (P=0.25), IPH-blood CNR (P=0.35), lumen SNR (P=0.60), and standard deviation (P=0.46) between the two techniques. ConclusionThe feasibility of fSNAP was validated. fSNAP can improve the imaging efficiency with similar performance to SNAP on carotid artery imaging. Magn Reson Med 77:753-758, 2017. (c) 2016 International Society for Magnetic Resonance in Medicine.
引用
收藏
页码:753 / 758
页数:6
相关论文
共 28 条
[1]   A method to reduce the Gibbs ringing artifact in MRI scans while keeping tissue boundary integrity [J].
Archibald, R ;
Gelb, A .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (04) :305-319
[2]   REGIONAL PHASE CORRECTION OF INVERSION-RECOVERY MR IMAGES [J].
BORRELLO, JA ;
CHENEVERT, TL ;
AISEN, AM .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (01) :56-67
[3]   Classification of human carotid atherosclerotic lesions with in vivo multicontrast magnetic resonance imaging [J].
Cai, JM ;
Hastukami, TS ;
Ferguson, MS ;
Small, R ;
Polissar, NL ;
Yuan, C .
CIRCULATION, 2002, 106 (11) :1368-1373
[4]   On the Gibbs phenomenon and its resolution [J].
Gottlieb, D ;
Shu, CW .
SIAM REVIEW, 1997, 39 (04) :644-668
[5]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[6]   IMPROVING MR IMAGE QUALITY IN THE PRESENCE OF MOTION BY USING REPHASING GRADIENTS [J].
HAACKE, EM ;
LENZ, GW .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (06) :1251-1258
[7]  
Hou P, 2005, AM J NEURORADIOL, V26, P1432
[8]   Phase-sensitive inversion recovery for detecting myocardial infarction using gadolinium-delayed hyperenhancement [J].
Kellman, P ;
Arai, AE ;
McVeigh, ER ;
Aletras, AH .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (02) :372-383
[9]   GUIDELINES FOR CAROTID ENDARTERECTOMY - A MULTIDISCIPLINARY CONSENSUS STATEMENT FROM THE AD-HOC-COMMITTEE, AMERICAN-HEART-ASSOCIATION [J].
MOORE, WS ;
BARNETT, HJM ;
BEEBE, HG ;
BERNSTEIN, EF ;
BRENER, BJ ;
BROTT, T ;
CAPLAN, LR ;
DAY, A ;
GOLDSTONE, J ;
HOBSON, RW ;
KEMPCZINSKI, RF ;
MATCHAR, DB ;
MAYBERG, MR ;
NICOLAIDES, AN ;
NORRIS, JW ;
RICOTTA, JJ ;
ROBERTSON, JT ;
RUTHERFORD, RB ;
THOMAS, D ;
TOOLE, JF ;
TROUT, HH ;
WIEBERS, DO .
STROKE, 1995, 26 (01) :188-201
[10]  
Noeske R, 2000, MAGN RESON MED, V44, P978, DOI 10.1002/1522-2594(200012)44:6<978::AID-MRM22>3.0.CO