A randomized controlled trial of interrupted versus continuous suturing techniques for radiocephalic fistulas

被引:17
作者
Aitken, Emma [1 ]
Jeans, Eddie [1 ]
Aitken, Margaret [1 ]
Kingsmore, David [1 ]
机构
[1] Western Infirm & Associated Hosp, Dept Renal Surg, Glasgow G11 6NY, Lanark, Scotland
关键词
VASCULAR ACCESS; ARTERIOVENOUS-FISTULAS; INTIMAL HYPERPLASIA; HEMODIALYSIS; STENOSIS; PATENCY; ANASTOMOSIS; GUIDELINES; MISMATCH; DIALYSIS;
D O I
10.1016/j.jvs.2015.07.083
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: Continuous suturing techniques have conventionally been used for the end-to-side anastomoses of radiocephalic fistulas (RCFs); however, primary patency rates are poor. Only 50% to 60% of RCFs ever achieve functional patency. We hypothesized that a hybrid interrupted-continuous suturing technique (as used in many microsurgical procedures) may improve outcomes in fistulas constructed from small vessels. Methods: A randomized controlled trial comparing hybrid interrupted-continuous (n = 42) with continuous (n = 36) suturing techniques for RCF was undertaken. Patients were excluded if vessels were <1.8 mm in diameter or if previous ipsilateral fistula had been attempted. A priori power calculation indicated that a sample size of 78 patients was required to detect an improvement in patency from 50% to 80% (alpha =.05, beta =.8). The primary end point was primary patency at 6 weeks (assessed by a blinded observer for the presence of thrill and bruit). Secondary end points were immediate patency, functional patency (assessed clinically and by ultrasound) at 6 weeks, and presence of anastomotic stenosis. Results: Groups were comparable for basic patient demographics, operating surgeon, and vessel diameter as measured on preoperative ultrasound (mean age, 58.9 +/- 13 years; 68% male). Primary patency at 6 weeks was higher in the hybrid interrupted-continuous suturing technique group (71% vs 47%; P =.01). Immediate patency was also higher in the hybrid interrupted-continuous suturing technique group (93% vs 67%; P <.001). There was no significant difference in functional patency at 6 weeks (52% vs 36%; P =.18). Three patients developed an anastomotic stenosis. All were in the hybrid interrupted-continuous suturing technique group. One patient from the interrupted suturing technique cohort required re-exploration for bleeding. Conclusions: A hybrid interrupted-continuous suturing technique yielded higher immediate and 6-week primary patency rates for RCF. The hybrid interrupted-continuous suturing technique may improve anastomotic compliance and reduce the narrowing and puckering that can occur on suture tightening in small-caliber vessels. Based on these findings, consideration should be given to performing hybrid interrupted-continuous anastomoses for RCFs.
引用
收藏
页码:1575 / 1582
页数:8
相关论文
共 44 条
  • [41] Animal model to compare the effects of suture technique on cross-sectional compliance on end-to-side anastomoses
    Tozzi, P
    Hayoz, D
    Ruchat, P
    Corno, A
    Oedman, C
    Botta, U
    von Segesser, LK
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2001, 19 (04) : 477 - 481
  • [42] Tzeng YS, 2011, ANN TRANSPL, V16, P12
  • [43] Vascular Access Work Group, 2006, AM J KIDNEY DIS S, V148, pS248, DOI [10.1053/j.ajkd.2006.04.029, DOI 10.1053/J.AJKD.2006.04.029]
  • [44] Five years' world experience with nonpenetrating clips for vascular anastomoses
    Zeebregts, CJ
    Kirsch, WM
    van den Dungen, JJ
    Zhu, YH
    van Schilfgaarde, R
    [J]. AMERICAN JOURNAL OF SURGERY, 2004, 187 (06) : 751 - 760