Persistent and emerging pollutants in the blood of German adults: Occurrence of dechloranes, polychlorinated naphthalenes, and siloxanes

被引:46
作者
Fromme, Hermann [1 ,5 ]
Cequier, Enrique [2 ]
Kim, Jun-Tae [3 ]
Hanssen, Linda [4 ]
Hilger, Bettina [1 ]
Thomsen, Cathrine [2 ]
Chang, Yoon-Seok [3 ]
Voelkel, Wolfgang [1 ]
机构
[1] Bavarian Hlth & Food Safety Author, Dept Chem Safety & Toxicol, D-80538 Munich, Germany
[2] Norwegian Inst Publ Hlth, N-0403 Oslo, Norway
[3] Pohang Univ Sci & Technol POSTECH, Pohang 790784, South Korea
[4] NILU Norwegian Inst Air Res, NO-9296 Tromso, Norway
[5] Univ Munich, Inst & Outpatient Clin Occupat Social & Environm, D-80336 Munich, Germany
关键词
PCN; Dechloranes; Siloxanes; Blood; Exposure; Biomonitoring; CHROMATOGRAPHY-MASS-SPECTROMETRY; CYCLIC VOLATILE METHYLSILOXANES; POLYBROMINATED DIPHENYL ETHERS; HALOGENATED FLAME RETARDANTS; HUMAN-SERUM; HUMAN EXPOSURE; LAIZHOU BAY; PLASMA; PLUS; ENVIRONMENT;
D O I
10.1016/j.envint.2015.09.002
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Human biomonitoring is a valid method to determine exposure, identify time trends, and monitor the effects of restrictions and measures. To characterize the recent exposure of Germans to persistent or emerging substances, we analyzed 4 dechloranes, 33 polychlorinated naphthalenes (PCNs), and 3 cyclic volatile methyl siloxanes (cVMS) in 42 plasma samples. The samples were collected from blood donors on a random selection. The median values of both Dechlorane Plus (DDC-CO) isomers were 123 ng/gl.w. for anti-and 0.77 ng/g l.w. for syn-DDC-CO. The two other dethloranes were found at lower levels. The median level of Sigma - PCNs was 575 pg/g l.w. (range: 101-1406 pg/g l.w.). On average, the levels of PCNs in plasma were dominated by the congeners CN73, CN66/67, and CN51, which were responsible for approximately 71% of the total amount of PCNs. The cVMS octa-, dem-, and dodecamethylcyclotetrasiloxane could be determined in only some samples, with maximum values of 0.73, 0.48, and 0.79 mu g/l, respectively. Regarding dechloranes, our results are similar to those from other western countries but slightly lower than results from China. The levels of PCNs in German blood are similar to those observed in the USA, but considerably lower than those reported for Korea. Using a preliminary TEF (toxic equivalency factor), the mean TEQ of the 9 quantifiable PCNs in Germany was low (0.36 pg TEQ/g l.w.). The PCN levels in our study group are lower compared to previous studies. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:292 / 298
页数:7
相关论文
共 33 条
  • [11] EC/HC (Environment Canada/Health Canada), 2008, DRAFT SCREEN ASS CHA
  • [12] The Toxicological Effects of Halogenated Naphthalenes: A Review of Aryl Hydrocarbon Receptor-Mediated (Dioxin-like) Relative Potency Factors
    Falandysz, Jerzy
    Fernandes, Alwyn
    Gregoraszczuk, Ewa
    Rose, Martin
    [J]. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART C-ENVIRONMENTAL CARCINOGENESIS & ECOTOXICOLOGY REVIEWS, 2014, 32 (03) : 239 - 272
  • [13] Determination of low molecular weight silicones in plasma and blood of women after exposure to silicone breast implants by GC/MS
    Flassbeck, D
    Pfleiderer, B
    Grümping, R
    Hirner, AV
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (03) : 606 - 611
  • [14] PCBs, PCDD/Fs, and PBDEs in blood samples of a rural population in South Germany
    Fromme, Hermann
    Albrecht, Michael
    Appel, Markus
    Hilger, Bettina
    Voelkel, Wolfgang
    Liebl, Bernhard
    Roscher, Eike
    [J]. INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2015, 218 (01) : 41 - 46
  • [15] Plasma concentrations of cyclic volatile methylsiloxanes (cVMS) in pregnant and postmenopausal Norwegian women and self-reported use of personal care products (PCPs)
    Hanssen, Linda
    Warner, Nicholas A.
    Braathen, Tonje
    Odland, Jon O.
    Lund, Eiliv
    Nieboer, Evert
    Sandanger, Torkjel M.
    [J]. ENVIRONMENT INTERNATIONAL, 2013, 51 : 82 - 87
  • [16] Concentrations and trends of halogenated flame retardants in the pooled serum of residents of Laizhou Bay, China
    He, Songjie
    Li, Mingyuan
    Jin, Jun
    Wang, Ying
    Bu, Yunjie
    Xu, Meng
    Yang, Xianfeng
    Liu, Anming
    [J]. ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2013, 32 (06) : 1242 - 1247
  • [17] Polychlorinated Dibenzo-p-dioxins, Dibenzofurans, Biphenyls, and Naphthalenes in Plasma of Workers Deployed at the World Trade Center after the Collapse
    Horii, Yuichi
    Jiang, Qinting
    Hanari, Nobuyasu
    Lam, Paul K. S.
    Yamashita, Nobuyoshi
    Jansing, Robert
    Aldous, Kenneth M.
    Mauer, Matthew P.
    Eadon, George A.
    Kannan, Kurunthachalam
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2010, 44 (13) : 5188 - 5194
  • [18] Kannan K., 2015, COMMUNICATION
  • [19] NRC (National Research Council), 2006, HUM BIOM ENV CHEM
  • [20] Relative importance of polychlorinated naphthalenes compared to dioxins, and polychlorinated biphenyls in human serum from Korea: Contribution to TEQs and potential sources
    Park, Hyokeun
    Kang, Jung-Ho
    Baek, Song-Yee
    Chang, Yoon-Seok
    [J]. ENVIRONMENTAL POLLUTION, 2010, 158 (05) : 1420 - 1427