Indoor hygrothermal loads for the deterministic and stochastic design of the building envelope for dwellings in cold climates

被引:36
作者
Ilomets, Simo [1 ]
Kalamees, Targo [1 ]
Vinha, Juha [2 ]
机构
[1] Tallinn Univ Technol, Dept Civil Engn & Architecture, Nearly Energy Bldg Res Grp 0, Ehitajate Tee 5, EE-19086 Tallinn, Estonia
[2] Tampere Univ Technol, Dept Civil Engn, Tampere, Finland
关键词
Indoor hygrothermal load; moisture excess; moisture production; ventilation air change; stochastic; deterministic; occupancy; RESIDENTIAL BUILDINGS; RELATIVE-HUMIDITY; THERMAL COMFORT; MODEL; TEMPERATURE; DAMPNESS;
D O I
10.1177/1744259117718442
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study, several years of field measurements of indoor hygrothermal loads in 237 dwelling units are analysed. Moisture excess is calculated from hourly values of temperature, and relative humidity measured both indoors and outdoors. Air change rate and moisture production in bedrooms are calculated on the basis of carbon dioxide measurements. It is found that indoor temperature profiles differ depending on whether a building has central heating, a stove or combined heating system. The determined average moisture excess value, 2.8g/m(3) with a standard deviation of 1.6g/m(3) for cold periods, can be used in stochastic calculations. Critical values for moisture excess at the 90th percentile, ranging from 3-8g/m(3), depending upon occupancy rates, can be used in the deterministic analysis. Averages and weekly maxima of moisture excess in the study are reported at different percentiles. Considerable deviations from the EN ISO 13788 standard are discovered, concerning the breaking point depending on outdoor temperature and moisture excess during the summer. The average and critical moisture production in bedroom is presented and insufficient ventilation determined based on measurements. During the heating period, the air change rate is relatively stable while moisture production levels increase along with the dropping outdoor temperature. Two indoor temperatures and three humidity models with different levels of detail and influencing factors are proposed. Temperature and humidity loads derived using the proposed models can be used to determine the indoor hygrothermal boundary conditions for the building envelope of dwellings in cold climates.
引用
收藏
页码:547 / 577
页数:31
相关论文
共 40 条
[1]  
[Anonymous], 2007, Indoor Environmental Input Parameters for Design and Assessment of Energy Performance of Buildings Addressing Indoor Air Quality, Thermal Environment, Lighting and Acoustics
[2]  
[Anonymous], 2009, 160P ASHRAE
[3]  
[Anonymous], 2011, **NON-TRADITIONAL**
[4]  
[Anonymous], 2004, Standard 55. Thermal Environment Conditions for Human Occupancy
[5]  
[Anonymous], 2012, 13788 EN ISO
[6]  
[Anonymous], 2007, 15026 CEN
[7]  
[Anonymous], 2000, 13829 EN
[8]  
Arena L, 2010, P BUILD ENCL SCIENBC, P1
[9]   Measured indoor hygrothermal conditions and occupancy levels in an arctic Swedish multi-family building [J].
Bagge, Hans ;
Johansson, Dennis ;
Lindstrii, Lotti .
HVAC&R RESEARCH, 2014, 20 (04) :376-383
[10]   Thermal comfort in residential buildings - Failure to predict by Standard model [J].
Becker, R. ;
Paciuk, M. .