Electrical characterization of CdTe pixel detectors with Al Schottky anode

被引:30
作者
Turturici, A. A. [1 ]
Abbene, L. [1 ]
Gerardi, G. [1 ]
Principato, F. [1 ]
机构
[1] Univ Palermo, Dipartimento Fis & Chim, I-90128 Palermo, Italy
关键词
CdTe; Schottky contacts; Polarization; Pixel detectors; X-ray and gamma ray spectroscopy; CURRENT-VOLTAGE CHARACTERISTICS; NUCLEAR RADIATION DETECTORS; CHARGE-LIMITED CURRENTS; CDZNTE DETECTORS; POLARIZATION PHENOMENA; SPECTRA;
D O I
10.1016/j.nima.2014.07.011
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Pixelated Schottky Al/p-CdTe/Pt detectors are very attractive devices for high-resolution X-ray spectroscopic imaging, even though they suffer from bias-induced time instability (polarization). In this work, we present the results of the electrical characterization of a (4 x 4) pixelated Schottky Al/p-CdTe/Pt detector. Current-voltage (I-V) characteristics and current transients were investigated at different temperatures. The results show deep levels that play a dominant role in the charge transport mechanism. The conduction mechanism is dominated by the space charge limited current (SCLC) both under forward bias and at high reverse bias. Schottky barrier height of the Al/CdTe contact was estimated by using the thermionic-field emission model at low reverse bias voltages. Activation energy of the deep levels was measured through the analysis of the reverse current transients at different temperatures. Finally, we employed an analytical method to determine the density and the energy distribution of the traps from SCLC current-voltage characteristics. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:476 / 482
页数:7
相关论文
共 50 条
  • [31] Effects of Heating on Electrical and Spectral Properties of In/CdTe/Au X- and γ-ray Detectors with a Schottky Barrier or Laser-induced p-n Junction
    Nishizawa, Junichi
    Gnatyuk, Volodymyr
    Zelenska, Kateryna
    Aoki, Toru
    SENSORS AND MATERIALS, 2020, 32 (11) : 3801 - 3812
  • [32] Characterization of CdTe and CdZnTe detectors for gamma-ray imaging applications
    Verger, L
    Boitel, M
    Gentet, MC
    Hamelin, R
    Mestais, C
    Mongellaz, F
    Rustique, J
    Sanchez, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2) : 297 - 309
  • [33] Spectral response characterization of CdTe sensors of different pixel size with the IBEX ASIC
    Zambon, P.
    Radicci, V.
    Trueb, P.
    Disch, C.
    Rissi, M.
    Sakhelashvili, T.
    Schneebeli, M.
    Broennimann, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 892 : 106 - 113
  • [34] Test Beam Characterization of 3-D Silicon Pixel Detectors
    Mathes, Markus
    Cristinziani, M.
    Da Via, C.
    Garcia-Sciveres, M.
    Einsweiler, K.
    Hasi, J.
    Kenney, C.
    Parker, S. I.
    Reuen, L.
    Ruspa, M.
    Velthuis, J.
    Watts, S.
    Wermes, Norbert
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (06) : 3731 - 3735
  • [35] Effect of Sulfur Treatment on the γ-ray Detection Quality of Al/CdTe/Pt Schottky Diode
    Yamazato, Masaaki
    Yamauchi, Tetsuya
    Ohno, Ryoichi
    Higa, Akira
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 5053 - +
  • [36] Electrical characterization of Ni/Al0.09Ga0.91N Schottky barrier diodes as a function of temperature
    Akkaya, A.
    Esmer, L.
    Karaaslan, T.
    Cetin, H.
    Ayyildiz, E.
    MATERIALS SCIENCE IN SEMICONDUCTOR PROCESSING, 2014, 28 : 127 - 134
  • [37] The use of Schottky CdTe detectors for high-energy astronomy: application to the detection plane of the instrument SVOM/ECLAIRs
    Nasser, G.
    Godet, O.
    Atteia, J. -L.
    Amoros, C.
    Barret, D.
    Bordon, S.
    Cordier, B.
    Gevin, O.
    Gonzalez, F.
    Houret, B.
    Lacombe, K.
    Mandrou, P.
    Marty, W.
    Mercier, K.
    Pons, R.
    Rambaud, D.
    Ramon, P.
    Rouaix, G.
    Waegebaert, V.
    SPACE TELESCOPES AND INSTRUMENTATION 2014: ULTRAVIOLET TO GAMMA RAY, 2014, 9144
  • [38] Photon counting X-ray imaging with CdTe pixel detectors based on XPAD2 circuit
    Franchi, Romain
    Glasser, Francis
    Gasse, Adrien
    Clemens, Jean-Claude
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01) : 249 - 253
  • [39] The influence of manufacturing modes on the electrical and energy parameters of graphene/p-CdTe Schottky diodes
    Koziarskyi, I. P.
    Ilashchuk, M. I.
    Orletskyi, I. G.
    Koziarskyi, D. P.
    Myroniuk, L. A.
    Myroniuk, D. V.
    Ievtushenko, A. I.
    Maistruk, E. V.
    PHYSICA B-CONDENSED MATTER, 2023, 667
  • [40] Evaluation of Polarization Effects of e- Collection Schottky CdTe Medipix3RX Hybrid Pixel Detector
    Astromskas, Vytautas
    Gimenez, Eva N.
    Lohstroh, Annika
    Tartoni, Nicola
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (01) : 252 - 258