Electrical characterization of CdTe pixel detectors with Al Schottky anode

被引:30
|
作者
Turturici, A. A. [1 ]
Abbene, L. [1 ]
Gerardi, G. [1 ]
Principato, F. [1 ]
机构
[1] Univ Palermo, Dipartimento Fis & Chim, I-90128 Palermo, Italy
关键词
CdTe; Schottky contacts; Polarization; Pixel detectors; X-ray and gamma ray spectroscopy; CURRENT-VOLTAGE CHARACTERISTICS; NUCLEAR RADIATION DETECTORS; CHARGE-LIMITED CURRENTS; CDZNTE DETECTORS; POLARIZATION PHENOMENA; SPECTRA;
D O I
10.1016/j.nima.2014.07.011
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Pixelated Schottky Al/p-CdTe/Pt detectors are very attractive devices for high-resolution X-ray spectroscopic imaging, even though they suffer from bias-induced time instability (polarization). In this work, we present the results of the electrical characterization of a (4 x 4) pixelated Schottky Al/p-CdTe/Pt detector. Current-voltage (I-V) characteristics and current transients were investigated at different temperatures. The results show deep levels that play a dominant role in the charge transport mechanism. The conduction mechanism is dominated by the space charge limited current (SCLC) both under forward bias and at high reverse bias. Schottky barrier height of the Al/CdTe contact was estimated by using the thermionic-field emission model at low reverse bias voltages. Activation energy of the deep levels was measured through the analysis of the reverse current transients at different temperatures. Finally, we employed an analytical method to determine the density and the energy distribution of the traps from SCLC current-voltage characteristics. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:476 / 482
页数:7
相关论文
共 50 条
  • [21] Characterization of indium and solder bump bonding for pixel detectors
    Cihangir, S
    Kwan, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 476 (03) : 670 - 675
  • [22] Extensive testing of Schottky CdTe detectors for the ECLAIRs X-/gamma-ray camera on board the SVOM mission
    Remoue, N.
    Barret, D.
    Godet, O.
    Mandrou, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 618 (1-3) : 199 - 208
  • [23] Electric Field and Current Transport Mechanisms in Schottky CdTe X-ray Detectors under Perturbing Optical Radiation
    Cola, Adriano
    Farella, Isabella
    SENSORS, 2013, 13 (07): : 9414 - 9434
  • [24] Single photon counting X-ray imaging with Si and CdTe single chip pixel detectors and multichip pixel modules
    Löcker, M
    Fischer, P
    Krimmel, S
    Krüger, H
    Lindner, M
    Nakazawa, K
    Takahashi, T
    Wermes, N
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (04) : 1717 - 1723
  • [25] Performance Comparison of X- and γ-Ray CdTe Detectors With MoOx, TiOx, and TiN Schottky Contacts
    Maslyanchuk, O.
    Solovan, M.
    Brus, V
    Maryanchuk, P.
    Maistruk, E.
    Fodchuk, I
    Gnatyuk, V
    Aoki, T.
    Lambropoulos, C.
    Potiriadis, C.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2018, 65 (07) : 1365 - 1370
  • [26] Development of Low-Noise Front-End ASIC for Hybrid CdTe Pixel Detectors
    Sato, Goro
    Kishishita, Tetsuichi
    Ikeda, Hirokazu
    Sakumura, Takuto
    Takahashi, Tadayuki
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (03) : 1370 - 1375
  • [27] Experimental results from Al/p-CdTe/Pt X-ray detectors
    Abbene, L.
    Gerardi, G.
    Turturici, A. A.
    Del Sordo, S.
    Principato, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 730 : 135 - 140
  • [28] Design, fabrication and characterization of SOI pixel detectors of ionizing radiation
    Tomaszewski, D
    Domanski, K
    Grabiec, P
    Grodner, M
    Jaroszewicz, B
    Klatka, T
    Kociubinski, A
    Koziel, M
    Kucewicz, W
    Kucharski, K
    Kuta, S
    Marczewski, J
    Niemiec, H
    Sapor, M
    Szelezniak, M
    SCIENCE AND TECHNOLOGY OF SEMICONDUCTOR-ON-INSULATOR STRUCTURES AND DEVICES OPERATING IN A HARSH ENVIRONMENT, 2005, 185 : 291 - 296
  • [29] Effect of He plasma treatment on the rectification properties of Al/CdTe Schottky contacts
    Toyama, H
    Yamazato, M
    Higa, A
    Maehama, T
    Ohno, R
    Toguchi, M
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2005, 44 (9A): : 6742 - 6746
  • [30] Improvement in γ-ray detection quality of Al/CdTe/Pt Schottky-type radiation detector by sulfur treatment
    Yamazato, Masaaki
    Higa, Akira
    Fukuhara, Yasumasa
    Toyama, Hiroyuki
    Yamanoha, Satoru
    Owan, Ikumi
    Ohno, Ryoichi
    Toguchi, Minoru
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 2006, 45 (46-50): : L1263 - L1265