Patient Specific Quality Assurance Using Machine Log Files for the Mevion S250i Proton Therapy System

被引:0
|
作者
Bunker, A. [1 ]
Ahmad, S. [1 ]
Chen, Y. [1 ]
机构
[1] Univ Oklahoma, Hlth Sci Ctr, Oklahoma City, OK USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
TU-C1000-G
引用
收藏
页码:E325 / E325
页数:1
相关论文
共 50 条
  • [31] Verification of dose and dose rate for quality assurance of spread-out-Bragg-peak proton FLASH radiotherapy using machine log files
    Oliaei Motlagh, Seyyedeh Azar
    Vander Stappen, Francois
    Kim, Michele M.
    Labarbe, Rudi
    Hotoiu, Lucian
    Pin, Arnaud
    Nilsson, Rasmus
    Traneus, Erik
    Cengel, Keith A.
    Zou, Wei
    Teo, Boon-Keng Kevin
    Dong, Lei
    Diffenderfer, Eric S.
    MEDICAL PHYSICS, 2025,
  • [32] Systematic Analysis of the Neutron Equivalent Dose in a Mevion S250 Proton Therapy Machine Using Geant4 Monte Carlo Simulation
    Tatari, N.
    Baradaran-Ghahfarokhi, M.
    Roeder, B.
    Zhao, T.
    Khan, R.
    Sobotka, L.
    Darafsheh, A.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [33] Development of a Log File Based Patient-Specific Quality Assurance for PBS Proton Therapy Using Open-Source Software Within the RayStation Treatment Planning System
    Chiang, B.
    Meyer, J.
    Wong, T.
    Maes, D.
    MEDICAL PHYSICS, 2022, 49 (06) : E375 - E375
  • [34] Simulation of Conformal Arc Proton Therapy Using the MEVION-S250 System Considering Beam Shaping with a Multi-Leaf Collimator
    Ferguson, S.
    Ahmad, S.
    Algan, O.
    Herman, T.
    Ali, I.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [35] Log File-Based Patient Specific Quality Assurance: 5 Years of Experience in Pencil Beam Scanning Pediatric Proton Therapy
    Ates, O.
    Pirlepesov, F.
    Hua, C.
    Merchant, T. E.
    Zhao, L.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [36] Volumetric Patient-Specific Quality Assurance for VMAT Treatment Delivery Using the Dynalog Files
    Schreibmann, E.
    Dhabaan, A.
    Elder, E.
    Fox, T.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [37] A deterministic algorithm for patient-specific quality assurance in online adaptive proton therapy
    Burlacu, T.
    Lathouwers, D.
    Perko, Z.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S78 - S79
  • [38] Quality assurance for mixed electron-photon beam radiation therapy using treatment log files and MapCHECK
    Tai, Yee Man
    Heng, Veng Jean
    Renaud, Marc-Andre
    Serban, Monica
    Seuntjens, Jan
    MEDICAL PHYSICS, 2023, 50 (12) : 7996 - 8008
  • [39] Quality Assurance for Mixed Electron-Photon Beam Radiation Therapy Using Treatment Log Files and MapCHECK
    Tai, Y.
    Heng, V.
    Renaud, M.
    Serban, M.
    Seuntjens, J.
    MEDICAL PHYSICS, 2022, 49 (06) : E832 - E833
  • [40] Prediction of portal dosimetry quality assurance results using log files-derived errors and machine learning techniques
    Lew, Kah Seng
    Chua, Clifford Ghee Ann
    Koh, Calvin Wei Yang
    Lee, James Cheow Lei
    Park, Sung Yong
    Tan, Hong Qi
    FRONTIERS IN ONCOLOGY, 2023, 12