Intraobserver reliability of landmark identification in cone-beam computed tomography-synthesized two-dimensional cephalograms versus conventional cephalometric radiography: A preliminary study

被引:11
作者
Chen, Mu-Hsiung [1 ,2 ]
Chang, Jenny Zwei-Chieng [2 ,3 ]
Kok, Sang-Heng [2 ,3 ]
Chen, Yi-Jane [2 ,3 ]
Huang, Yao-Der [2 ]
Cheng, Kai-Yuan [1 ]
Lin, Chun-Pin [2 ,3 ]
机构
[1] Cent Taiwan Univ Sci & Technol, Dept Med Imaging & Radiol Sci, Taichung 40605, Taiwan
[2] Natl Taiwan Univ Hosp, Dept Dent, Taipei, Taiwan
[3] Natl Taiwan Univ, Grad Inst Clin Dent, Sch Dent, Taipei, Taiwan
关键词
cephalometric landmarks; cone-beam computed tomography (CBCT); digital cephalogram; orthodontic diagnosis; PHOSPHOR IMAGING-SYSTEM; LATERAL CEPHALOGRAMS; IN-VIVO; IMAGES; CT; REPRODUCIBILITY; REDUCTION; PRECISION; CBCT;
D O I
10.1016/j.jds.2013.02.012
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background/purpose: The aim of the study was to examine the intraobserver reliability of landmark identification in cone-beam computed tomography (CBCT)-synthesized two-dimensional (2D) lateral cephalograms versus conventional digital cephalograms. Materials and methods: Twenty CBCT scans and the corresponding conventional lateral cephalograms were randomly selected. Two-dimensional lateral cephalograms were constructed from the three-dimensional CBCT scans by summing the voxels of the entire volume. All the images were imported into the computer using the analyzing software WinCeph version 8.0. Twenty landmarks in the CBCT-synthesized 2D cephalograms and conventional cephalograms were identified directly on the computer screen by an experienced orthodontist and the operation was repeated 2 weeks later. The x- and y-coordinates of each landmark were examined for intraobserver reliability. The differences in landmark reproducibility between the two modalities were analyzed with a paired Student t test. Results: The horizontal and vertical errors of landmark identification by the two modalities of cephalometry ranged from 0.18 mm to 1.67 mm. Fewer landmarks in CBCT-synthesized cephalograms had intraobserver error > 1 mm. Significantly better reliability was observed in CBCT-synthesized cephalograms at the menton, lower central incisor edge, and lower central incisor root apex landmarks in the horizontal dimension and at the pogonion, gnathion, menton, upper central incisor root apex, lower central incisor root apex, and lower molar landmarks in the vertical dimension. Scatter-plots revealed a characteristic pattern of error distribution for each landmark. Conclusion: CBCT-synthesized lateral cephalograms can successfully replace conventional cephalograms for orthodontic diagnosis. Copyright (C) 2013, Association for Dental Sciences of the Republic of China. Published by Elsevier Taiwan LLC. All rights reserved.
引用
收藏
页码:56 / 62
页数:7
相关论文
共 30 条
  • [1] Athanasiou AE., 1995, ORTHODONTIC CEPHALOM
  • [2] RELIABILITY OF HEAD FILM MEASUREMENTS .1. LANDMARK IDENTIFICATION
    BAUMRIND, S
    FRANTZ, RC
    [J]. AMERICAN JOURNAL OF ORTHODONTICS, 1971, 60 (02): : 111 - &
  • [3] Comparison between conventional and cone-beam computed tomography-generated cephalograms
    Cattaneo, Paolo M.
    Bloch, Christian Borgkvist
    Calmar, Dorte
    Hjortshoj, Mette
    Melsen, Birte
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 134 (06) : 798 - 802
  • [4] Evaluation of ten extra-alveolar temporary anchorage device insertion sites by cone beam volumetric computer tomography: a pilot study
    Chen, Yi-Jyun
    Kao, Chia-Tze
    Huang, Tsui-Hsien
    [J]. JOURNAL OF DENTAL SCIENCES, 2010, 5 (01) : 21 - 29
  • [5] Reliability of landmark identification in cephalometric radiography acquired by a storage phosphor imaging system
    Chen, YJ
    Chen, SK
    Huang, HW
    Yao, CC
    Chang, HF
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (05) : 301 - 306
  • [6] Chen YJ, 2004, ANGLE ORTHOD, V74, P155
  • [7] Comparison of reliability in anatomical landmark identification using two-dimensional digital cephalometrics and three-dimensional cone beam computed tomography in vivo
    Chien, P. C.
    Parks, E. T.
    Eraso, F.
    Hartsfield, J. K., Jr.
    Roberts, W. E.
    Ofner, S.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2009, 38 (05) : 262 - 273
  • [8] Cohen A M, 1984, Br J Orthod, V11, P44
  • [9] Observer reliability of three-dimensional cephalometric landmark identification on cone-beam computerized tomography
    de Oliveira, Ana Emilia F.
    Cevidanes, Lucia Helena S.
    Phillips, Ceib
    Motta, Alexandre
    Burke, Brandon
    Tyndall, Donald
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 107 (02): : 256 - 265
  • [10] Effect of image compression of digital lateral cephalograms on the reproducibility of cephalometric points
    Duarte, H. E. M.
    Vieck, R.
    Siqueira, D. F.
    Angelieri, F.
    Bommarito, S.
    Dalben, G.
    Sannomiya, E. K.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2009, 38 (06) : 393 - 400