Simultaneous determination of ascorbic acid, dopamine and uric acid based on tryptophan functionalized graphene

被引:172
作者
Lian, Qianwen [1 ]
He, Zhifang [1 ]
He, Qian [1 ]
Luo, Ai [1 ]
Yan, Kaiwang [1 ]
Zhang, Dongxia [1 ]
Lu, Xiaoquan [2 ]
Zhou, Xibin [1 ]
机构
[1] Northwest Normal Univ, Coll Geog & Environm Sci, Key Lab Bioelectrochem & Environm Anal Gansu Prov, Lanzhou 730070, Peoples R China
[2] Northwest Normal Univ, Coll Chem & Chem Engn, Key Lab Bioelectrochem & Environm Anal Gansu Prov, Lanzhou 730070, Peoples R China
基金
中国国家自然科学基金;
关键词
Graphene; Tryptophan; Ascorbic acid; Dopamine; Uric acid; Simultaneous determination; OXIDE MODIFIED ELECTRODE; GLASSY-CARBON ELECTRODE; SIMULTANEOUS ELECTROCHEMICAL DETERMINATION; FILM-MODIFIED ELECTRODE; SENSITIVE DETERMINATION; NANOPARTICLES; SENSOR; PERFORMANCE;
D O I
10.1016/j.aca.2014.03.032
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new type of tryptophan-functionalized graphene nanocomposite (Trp-GR) was synthesized by utilizing a facile ultrasonic method via pi-pi conjugate action between graphene (GR) and tryptophan (Trp) molecule. The material as prepared had well dispersivity in water and better conductivity than pure GR. The surface morphology of Trp-GR was characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM) and Raman spectroscopy. The electrochemical behaviors of ascorbic acid (AA), dopamine (DA), and uric acid (UA) were investigated by cyclic voltammetry (CV) on the surface of Trp-GR. The separation of the oxidation peak potentials for AA-DA, DA-UA and UA-AA was about 182 mV, 125mV and 307 mV, which allowed simultaneously determining AA, DA, and UA. Differential pulse voltammetery (DPV) was used for the determination of AA, DA, and UA in their mixture. Under optimum conditions, the linear response ranges for the determination of AA, DA, and UA were 0.2-12.9 mM, 0.5-110 mu M, and 10-1000 mu M, with the detection limits (S/N= 3) of 10.09 mu M, 0.29 mu M and 1.24 mu M, respectively. Furthermore, the modified electrode was investigated for real sample analysis. Crown Copyright (C) 2014 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:32 / 39
页数:8
相关论文
共 33 条
  • [1] Stable Aqueous Dispersions of Noncovalently Functionalized Graphene from Graphite and their Multifunctional High-Performance Applications
    An, Xiaohong
    Simmons, Trevor John
    Shah, Rakesh
    Wolfe, Christopher
    Lewis, Kim M.
    Washington, Morris
    Nayak, Saroj K.
    Talapatra, Saikat
    Kar, Swastik
    [J]. NANO LETTERS, 2010, 10 (11) : 4295 - 4301
  • [2] Benvidi A., 2014, BIOSENSORS BIOELECTR
  • [3] Electrochemical sensor for epinephrine based on a glassy carbon electrode modified with graphene/gold nanocomposites
    Cui, Fei
    Zhang, Xiaoli
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 669 : 35 - 41
  • [4] Simultaneous determination of dopamine, ascorbic acid, and uric acid using helical carbon nanotubes modified electrode
    Cui, Rongjing
    Wang, Xueying
    Zhang, Genhua
    Wang, Chen
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2012, 161 (01): : 1139 - 1143
  • [5] Raman spectrum of graphene and graphene layers
    Ferrari, A. C.
    Meyer, J. C.
    Scardaci, V.
    Casiraghi, C.
    Lazzeri, M.
    Mauri, F.
    Piscanec, S.
    Jiang, D.
    Novoselov, K. S.
    Roth, S.
    Geim, A. K.
    [J]. PHYSICAL REVIEW LETTERS, 2006, 97 (18)
  • [6] Water dispersible graphene noncovalently functionalized with tryptophan and its poly(vinyl alcohol) nanocomposite
    Guo, Juan
    Ren, Lulu
    Wang, Ruiyu
    Zhang, Chao
    Yang, Yang
    Liu, Tianxi
    [J]. COMPOSITES PART B-ENGINEERING, 2011, 42 (08) : 2130 - 2135
  • [7] Simultaneous determination of catechol and hydroquinone using electrospun carbon nanofibers modified electrode
    Guo, Qiaohui
    Huang, Jianshe
    Chen, Puqing
    Liu, Yang
    Hou, Haoqing
    You, Tianyan
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2012, 163 (01) : 179 - 185
  • [8] Simultaneous determination of ascorbic acid, dopamine and uric acid by use of a MWCNT modified carbon-ceramic electrode and differential pulse voltammetry
    Habibi, Biuck
    Pournaghi-Azar, Mohammad Hossien
    [J]. ELECTROCHIMICA ACTA, 2010, 55 (19) : 5492 - 5498
  • [9] Determination of nanomolar uric and ascorbic acids using enlarged gold nanoparticles modified electrode
    Kannan, P.
    John, S. Abraham
    [J]. ANALYTICAL BIOCHEMISTRY, 2009, 386 (01) : 65 - 72
  • [10] Simultaneous and sensitive determination of ascorbic acid, dopamine, uric acid, and tryptophan with silver nanoparticles-decorated reduced graphene oxide modified electrode
    Kaur, Balwinder
    Pandiyan, Thangarasu
    Satpati, Biswarup
    Srivastava, Rajendra
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2013, 111 : 97 - 106