Environmental fatigue of superelastic NiTi wire with two surface finishes

被引:15
作者
Racek, Jan [1 ]
Sittner, Petr [1 ,2 ]
机构
[1] CAS, Inst Phys, Na Slovance 2, Prague 18221, Czech Republic
[2] CAS, Nucl Phys Inst, Husinec Rez, Czech Republic
关键词
Nitinol; Shape memory alloy; Martensitic transformation; Surface damage; Electrochemical corrosion tests; Environmental fatigue tests; SHAPE-MEMORY ALLOY; CORROSION; TITANIUM; FRACTURE; STENT; SUSCEPTIBILITY; TRANSFORMATION; MECHANISM; BEHAVIOR; FAILURE;
D O I
10.1016/j.jmbbm.2020.104028
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Surface finish of NiTi is widely perceived to affect its biocompatibility and corrosion fatigue performance. The aim of this work was to find out, whether a carefully engineered surface oxide shows any beneficial effect over electropolished surface on the fatigue performance of superelastic NiTi wire mechanically cycled in simulated biofluid. Series of corrosion and environmental fatigue tensile tests was performed on superelastic NiTi wire with two different surface finishes frequently used in medical device industry. Open Circuit Potential reflecting the activity of chemical reactions on the surface of the wire cycled in electrochemical cell was continuously monitored during the fatigue tests. Microcracks at the surface of the fatigued NiTi wires were characterized by SEM and TEM. It was found that the carefully engineered 70 nm thick TiO2 oxide provides the NiTi wire with similar level of protection against the static corrosion as the less than 10 nm thin natural oxide on the electropolished wire and that it does not have any positive effect on its performance in environmental fatigue tests, whatsoever. On the contrary, the wire covered by the carefully engineered 70 nm thick TiO2 oxide displayed systematically poorer fatigue performance upon tensile cycling under specific critical loading conditions (strain amplitude <0.5% at large mean strains 1-7%).
引用
收藏
页数:15
相关论文
共 57 条
[11]   Reconstruction of phase distributions in NiTi helical spring: comparison of diffraction/scattering computed tomography and computational modeling [J].
Frost, M. ;
Sevcik, M. ;
Kaderavek, L. ;
Sittner, P. ;
Sedlak, P. .
SMART MATERIALS AND STRUCTURES, 2020, 29 (07)
[12]   CREVICE CORROSION OF TITANIUM IN AQUEOUS SALT SOLUTIONS [J].
GRIESS, JC .
CORROSION, 1968, 24 (04) :96-&
[13]   Can human mesenchymal stem cells survive on a NiTi implant material subjected to cyclic loading? [J].
Habijan, T. ;
Glogowski, T. ;
Kuehn, S. ;
Pohl, M. ;
Wittsiepe, J. ;
Greulich, C. ;
Eggeler, G. ;
Schildhauer, T. A. ;
Koeller, M. .
ACTA BIOMATERIALIA, 2011, 7 (06) :2733-2739
[14]   On the plastic deformation accompanying cyclic martensitic transformation in thermomechanically loaded NiTi [J].
Heller, L. ;
Seiner, H. ;
Sittner, P. ;
Sedlak, P. ;
Tyc, O. ;
Kaderavek, L. .
INTERNATIONAL JOURNAL OF PLASTICITY, 2018, 111 :53-71
[15]   Physical Simulation of the Random Failure of Implanted Braided NiTi Stents [J].
Hirmanova, Klara ;
Pilch, Jan ;
Racek, Jan ;
Heller, Ludk ;
Sittner, Petr ;
Recman, Luka ;
Petrenec, Martin ;
Sedlak, Petr .
JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2014, 23 (07) :2650-2658
[16]   Corrosion and metal release from overlapping arterial stents under mechanical and electrochemical stress - An experimental study [J].
Hol, Paul Johan ;
Gjerdet, Nils R. ;
Jonung, Torbjorn .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2019, 93 :31-35
[17]   Corrosion products and mechanism on NiTi shape memory alloy in physiological environment [J].
Hu, Tao ;
Chu, Chenglin ;
Xin, Yunchang ;
Wu, Shuilin ;
Yeung, Kelvin W. K. ;
Chu, Paul K. .
JOURNAL OF MATERIALS RESEARCH, 2010, 25 (02) :350-358
[18]  
Izquierdo J., 2016, ELECTROCHIM ACTA
[19]  
Jia WY, 1999, J BIOMED MATER RES, V48, P488, DOI 10.1002/(SICI)1097-4636(1999)48:4<488::AID-JBM14>3.3.CO
[20]  
2-4