Adaptations of aortic and pulmonary artery flow parameters measured by phase-contrast magnetic resonance angiography during supine aerobic exercise

被引:11
|
作者
Pieles, Guido E. [1 ,2 ]
Szantho, Gergely [1 ]
Rodrigues, Jonathan C. L. [3 ]
Lawton, Christopher B. [3 ]
Stuart, A. Graham [1 ]
Bucciarelli-Ducci, Chiara [2 ]
Turner, Mark S. [1 ]
Williams, Craig A. [4 ]
Tulloh, Robert M. R. [1 ]
Hamilton, Mark C. K. [2 ,3 ]
机构
[1] Bristol Royal Hosp C hildren, Bristol Heart Inst, Congenital Heart Unit, Bristol BS2 8HW, Avon, England
[2] Bristol Royal Infirm & Gen Hosp, Bristol Heart Inst, Cardiovasc Biomed Res Unit, Natl Inst Hlth Res, Bristol BS2 8HW, Avon, England
[3] Bristol Royal Infirm & Gen Hosp, Dept Radiol, Bristol BS2 8HW, Avon, England
[4] Univ Exeter, Coll Life & Environm Sci, Childrens Hlth & Exercise Res Ctr, Exeter EX1 2LU, Devon, England
关键词
Exercise adaptations; Blood flow; Magnetic resonance imaging; Imaging methodology; Feasibility; Cardio-pulmonary disease; STROKE VOLUME RESPONSE; BLOOD-FLOW; UPRIGHT EXERCISE; CARDIAC-FUNCTION; HEART-RATE; MR; REST; QUANTIFICATION; DETERMINANTS; CIRCULATION;
D O I
10.1007/s00421-014-2833-x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Increased oxygen uptake and utilisation during exercise depend on adequate adaptations of systemic and pulmonary vasculature. Recent advances in magnetic resonance imaging techniques allow for direct quantification of aortic and pulmonary blood flow using phase-contrast magnetic resonance angiography (PCMRA). This pilot study tested quantification of aortic and pulmonary haemodynamic adaptations to moderate aerobic supine leg exercise using PCMRA. Nine adult healthy volunteers underwent pulse gated free breathing PCMRA while performing heart rate targeted aerobic lower limb exercise. Flow was assessed in mid ascending and mid descending thoracic aorta (AO) and main pulmonary artery (MPA) during exercise at 180 % of individual resting heart rate. Flow sequence analysis was performed by experienced operators using commercial offline software (Argus, Siemens Medical Systems). Exercise related increase in HR (rest: 69 +/- A 10 b min(-1), exercise: 120 +/- A 13 b min(-1)) resulted in cardiac output increase (from 6.5 +/- A 1.4 to 12.5 +/- A 1.8 L min(-1)). At exercise, ascending aorta systolic peak velocity increased from 89 +/- A 14 to 122 +/- A 34 cm s(-1) (p = 0.016), descending thoracic aorta systolic peak velocity increased from 104 +/- A 14 to 144 +/- A 33 cm s(-1) (p = 0.004), MPA systolic peak velocity from 86 +/- A 18 to 140 +/- A 48 cm s(-1) (p = 0.007), ascending aorta systolic peak flow rate from 415 +/- A 83 to 550 +/- A 135 mL s(-1) (p = 0.002), descending thoracic aorta systolic peak flow rate from 264 +/- A 70 to 351 +/- A 82 mL s(-1) (p = 0.004) and MPA systolic peak flow rate from 410 +/- A 80 to 577 +/- A 180 mL s(-1) (p = 0.006). Quantitative blood flow and velocity analysis during exercise using PCMRA is feasible and detected a steep exercise flow and velocity increase in the aorta and MPA. Exercise PCMRA can serve as a research and clinical tool to help quantify exercise blood flow adaptations in health and disease and investigate patho-physiological mechanisms in cardio-pulmonary disease.
引用
收藏
页码:1013 / 1023
页数:11
相关论文
共 50 条
  • [21] Magnetic Resonance Assessment of Pulmonary (QP) to Systemic (QS) Flows Using 4D Phase-contrast Imaging: Pilot Study Comparison with Standard Through-plane 2D Phase-contrast Imaging
    Hanneman, Kate
    Sivagnanam, Milani
    Nguyen, Elsie T.
    Wald, Rachel
    Greiser, Andreas
    Crean, Andrew M.
    Ley, Sebastian
    Wintersperger, Bernd J.
    ACADEMIC RADIOLOGY, 2014, 21 (08) : 1002 - 1008
  • [22] Estimation of pulmonary vascular resistance in patients with pulmonary fibrosis by phase-contrast magnetic resonance imaging
    Ayukawa, Yuichiro
    Murayama, Sadayuki
    Tsuchiya, Nanae
    Yara, Satomi
    Fujita, Jiro
    JAPANESE JOURNAL OF RADIOLOGY, 2011, 29 (08) : 563 - 569
  • [23] MEASUREMENT OF ABSOLUTE EPICARDIAL CORONARY-ARTERY FLOW AND FLOW RESERVE WITH BREATH-HOLD CINE PHASE-CONTRAST MAGNETIC-RESONANCE-IMAGING
    CLARKE, GD
    ECKELS, R
    CHANEY, C
    SMITH, D
    DITTRICH, J
    HUNDLEY, WG
    NESSAIVER, M
    LI, HF
    PARKEY, RW
    PESHOCK, RM
    CIRCULATION, 1995, 91 (10) : 2627 - 2634
  • [24] Response to Letter to the Editor: "Reproducibility of flow and velocity parameters in intracranial arteries measured with phase-contrast magnetic resonance imaging; a methodological issue"
    de Verdier, Maria Correia
    Wikstrom, Johan
    NEURORADIOLOGY, 2016, 58 (09) : 951 - 951
  • [25] Phase-Contrast Magnetic Resonance Quantification of Normal Pulmonary Venous Return
    Goo, Hyun Woo
    Al-Otay, Abdulmajeed
    Grosse-Wortmann, Lars
    Wu, Shengping
    Macgowan, Christopher K.
    Yoo, Shi-Joon
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (03) : 588 - 594
  • [26] Response to Letter to the Editor: “Reproducibility of flow and velocity parameters in intracranial arteries measured with phase-contrast magnetic resonance imaging; a methodological issue”
    Maria Correia de Verdier
    Johan Wikström
    Neuroradiology, 2016, 58 : 951 - 951
  • [27] Changes in systemic and pulmonary blood flow distribution in normal adult volunteers in response to posture and exercise: a phase contrast magnetic resonance imaging study
    Wong, Derek T. H.
    Lee, Kyong-Jin
    Yoo, Shi-Joon
    Tomlinson, George
    Grosse-Wortmann, Lars
    JOURNAL OF PHYSIOLOGICAL SCIENCES, 2014, 64 (02) : 105 - 112
  • [28] CINE PHASE-CONTRAST MAGNETIC-RESONANCE-IMAGING FOR ANALYSIS OF FLOW PHENOMENA IN EXPERIMENTAL AORTIC DISSECTION
    IWAI, F
    SOSTMAN, HD
    EVANS, AJ
    NADEL, SN
    HEDLUND, LW
    BEAM, CA
    CHARLES, HC
    SPRITZER, CE
    INVESTIGATIVE RADIOLOGY, 1991, 26 (12) : 1071 - 1078
  • [29] Normal ranges and test-retest reproducibility of flow and velocity parameters in intracranial arteries measured with phase-contrast magnetic resonance imaging
    Maria Correia de Verdier
    Johan Wikström
    Neuroradiology, 2016, 58 : 521 - 531
  • [30] Cervical compressive myelopathy: flow analysis of cerebrospinal fluid using phase-contrast magnetic resonance imaging
    Bae, Yun Jung
    Lee, Joon Woo
    Lee, Eugene
    Yeom, Jin S.
    Kim, Ki-Jeong
    Kang, Heung Sik
    EUROPEAN SPINE JOURNAL, 2017, 26 (01) : 40 - 48