Performance of Four New Photoscreeners on Pediatric Patients With High Risk Amblyopia

被引:49
作者
Arnold, Robert W. [1 ]
Armitage, M. Diane
机构
[1] Ophthalm Associates, Anchorage, AK 99501 USA
关键词
MTI PHOTOSCREENERS; ANISOMETROPIA; CALIBRATION; CHILDREN;
D O I
10.3928/01913913-20131223-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: A new study by the American Academy of Pediatrics touts the benefits of photoscreening, especially in preverbal children who cannot yet perform monocular acuity screening. Emerging devices have not been compared in young and developmentally challenged children. Methods: Consecutive patients in a pediatric eye practice had a comprehensive eye examination and four photoscreens: PlusoptiX (PlusoptiX, Nuremburg, Germany), SPOT (PediaVision, Lake Mary, FL), iScreen (iScreen, Memphis, TN), and the GoCheckKids application (Gobiquity, Aliso Viejo, CA) for the iPhone 4s (Apple, Cupertino, CA) with Delta Center Crescent interpretation. They were validated according to the 2003 American Association for Pediatric Ophthalmology and Strabismus uniform guidelines. Results: One hundred eight children aged 1 to 12 years participated, with 56% having amblyopia risk factors and 10% having autism. For the four devices, sensitivity, specificity, and inconclusive results were as follows: PlusoptiX (83%, 86%, 23%), SPOT (80%, 85%, 4%), iScreen (75%, 88%, 13%) and iScreen (with Delta Center Crescent) (92%, 88%, 0%), and GoCheckKids (with Delta Center Crescent) (81%, 91%, 3%). Conclusions: Even in high risk and young children, current instrument- based screeners can reliably screen for refractive and strabismic risk factors that lead to amblyopia. Some devices can reduce the proportion of inclusive results in challenging cases.
引用
收藏
页码:46 / 52
页数:7
相关论文
共 17 条
[1]  
Arnold Robert W, 2006, Binocul Vis Strabismus Q, V21, P93
[2]  
Arnold Robert W, 2003, Alaska Med, V45, P34
[3]   Amblyopia Risk Factor Prevalence [J].
Arnold, Robert W. .
JOURNAL OF PEDIATRIC OPHTHALMOLOGY & STRABISMUS, 2013, 50 (04) :213-217
[4]   Calibration and Validation of Nine Objective Vision Screeners With Contact Lens-Induced Anisometropia [J].
Arnold, Robert W. ;
Davis, Bethanne ;
Arnold, Laura E. ;
Rowe, Kayla S. ;
Davis, Jodi M. .
JOURNAL OF PEDIATRIC OPHTHALMOLOGY & STRABISMUS, 2013, 50 (03) :184-190
[5]  
Arnold Robert W, 2012, Binocul Vis Strabolog Q Simms Romano, V27, P227
[6]  
Arnold Robert W, 2007, Binocul Vis Strabismus Q, V22, P148
[7]  
Arnold RW, 2006, AM ORTHOPT J, V56, P15
[9]   Preschool vision screening: What should we be detecting and how should we report it? Uniforn guidelines for reporting results of preschool vision screening studies [J].
Donahue, SP ;
Arnold, RW ;
Ruben, JB .
JOURNAL OF AAPOS, 2003, 7 (05) :314-316
[10]  
Enzenauer Robert W, 2003, Binocul Vis Strabismus Q, V18, P233