Blood speed imaging with an intraluminal array

被引:16
作者
Crowe, JR [1 ]
Shapo, BM
Stephens, DN
Bleam, D
Eberle, MJ
Céspedes, EI
Wu, CC
Muller, DWM
Kovach, JA
Lederman, RJ
O'Donnell, M
机构
[1] Univ Michigan, Dept Elect Engn & Comp Sci, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Internal Med, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[4] Endoson Corp, Rancho Cordova, CA 95670 USA
基金
美国国家卫生研究院;
关键词
D O I
10.1109/58.842055
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In applications in which Doppler processing is not possible, such as side-looking intravascular imaging systems, decorrelation methods can be used to estimate blood speed. Here, a method is presented measuring relative blood speed using an FIR filter bank to estimate temporal decorrelation rates. It can be implemented in a modern commercially available ultrasound imaging system with no additional hardware. Both simulations and experiments using an intraluminal scanner appropriate for coronary artery applications have tested the system, In this study, the FIR filter bank is contrasted with previous methods, and its utility is further demonstrated with real-time color flow images from a pig model.
引用
收藏
页码:672 / 681
页数:10
相关论文
共 23 条
[1]   A NEW TIME DOMAIN TECHNIQUE FOR VELOCITY-MEASUREMENTS USING DOPPLER ULTRASOUND [J].
BARBER, WD ;
EBERHARD, JW ;
KARR, SG .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (03) :213-229
[2]   DIRECTIONAL CORONARY ATHERECTOMY VERSUS BALLOON ANGIOPLASTY [J].
BITTL, JA .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 329 (04) :273-274
[3]  
BONNEFOUS O, P 1986 IEEE ULTR S, P855
[4]   Simultaneous morphological and functional assessment of a renal artery stent intervention with intravascular ultrasound [J].
Carlier, SG ;
Li, WG ;
Céspedes, EI ;
van der Steen, AFW ;
Hamburger, JN ;
Bom, N ;
Serruys, PW .
CIRCULATION, 1998, 97 (25) :2575-2576
[5]  
CARLIER SG, 1997, CIRCULATION 70 SCI S, V96, P7031
[6]   THEORY OF ULTRASOUND DOPPLER-SPECTRA VELOCIMETRY FOR ARBITRARY BEAM AND FLOW CONFIGURATIONS [J].
CENSOR, D ;
NEWHOUSE, VL ;
VONTZ, T ;
ORTEGA, HV .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (09) :740-751
[7]  
CESPEDES EI, 1998, J VASC INVEST, V4, P39
[8]  
CROWE JR, P 1996 IEEE ULTR S, P1481
[9]   FLOW VELOCITY PROFILE VIA TIME-DOMAIN CORRELATION ERROR ANALYSIS AND COMPUTER-SIMULATION [J].
FOSTER, SG ;
EMBREE, PM ;
OBRIEN, WD .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1990, 37 (03) :164-175
[10]   Vessel wall detection and blood noise reduction in intravascular ultrasound imaging [J].
Gronningsaeter, A ;
Angelsen, BAJ ;
Heimdal, A ;
Torp, HG .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1996, 43 (03) :359-369