Lower limb ischemic complications after the use of arterial puncture closure devices

被引:25
作者
Biancari, F. [1 ]
Ylonen, K. [1 ]
Mosorin, M. [1 ]
Lepojarvi, M. [1 ]
Juvonen, T. [1 ]
机构
[1] Oulu Univ Hosp, Div Cardiothorac & Vasc Surg, Dept Surg, Oulu 90029, Finland
关键词
angio-seal; arterial puncture closure device; lower limb ischemia; complication;
D O I
10.1016/j.ejvs.2006.04.023
中图分类号
R61 [外科手术学];
学科分类号
摘要
We report three cases of lower limb ischemia occurring after the use of arterial puncture closure devices (APCDs). In two patients, who have undergone percutaneous angioplasty of lower limb arteries, the Angio-Seal APCD led to thrombosis of the common femoral artery. In another patient who has undergone coronary angiography, this device has led to dissection of the common femoral artery. Since these observations seem to not be merely sporadic, radiologists and cardiologists as well as vascular surgeons should be aware of their possible occurrence in order to avoid these complications and to provide promptly an adequate treatment.
引用
收藏
页码:504 / 505
页数:2
相关论文
共 10 条
  • [1] The use of the angioseal device for femoral artery closure
    Abando, A
    Hood, D
    Weaver, F
    Katz, S
    [J]. JOURNAL OF VASCULAR SURGERY, 2004, 40 (02) : 287 - 290
  • [2] Incidence of vascular injuries after use of the angio-seal closure device following endovascular procedures in a single center
    Castelli, P
    Caronno, R
    Piffaretti, G
    Tozzi, M
    Lomazzi, C
    [J]. WORLD JOURNAL OF SURGERY, 2006, 30 (03) : 280 - 284
  • [3] Cremonesi A, 1998, J INVASIVE CARDIOL, V10, P464
  • [4] Surgical complications from hemostatic puncture closure devices
    Eidt, JF
    Habibipour, S
    Saucedo, JF
    McKee, J
    Southern, F
    Barone, GW
    Talley, JD
    Moursi, M
    [J]. AMERICAN JOURNAL OF SURGERY, 1999, 178 (06) : 511 - 515
  • [5] Local vascular complications after use of the hemostatic puncture closure device Angio-Seal™
    Kirchhof, C
    Schickel, S
    Schmidt-Lucke, C
    Schmidt-Lucke, JA
    [J]. VASA-JOURNAL OF VASCULAR DISEASES, 2002, 31 (02): : 101 - 106
  • [6] Arterial puncture closing devices compared with standard manual compression after cardiac catheterization -: Systematic review and meta-analysis
    Koreny, M
    Riedmüller, E
    Nikfardjam, M
    Siostrzonek, P
    Müllner, M
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2004, 291 (03): : 350 - 357
  • [7] Efficacy and complications of Angioseal in antegrade puncture
    Mukhopadhyay, K
    Puckett, MA
    Roobottom, CA
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2005, 56 (03) : 409 - 412
  • [8] Vascular complications associated with arteriotomy closure devices in patients undergoing percutaneous coronary procedures - A meta-analysis
    Nikolsky, E
    Mehran, R
    Halkin, A
    Aymong, ED
    Mintz, GS
    Lasic, Z
    Negoita, M
    Fahy, M
    Krieger, S
    Moussa, I
    Moses, JW
    Stone, GW
    Leon, MB
    Pocock, SJ
    Dangas, G
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (06) : 1200 - 1209
  • [9] Prospective comparison of collagen plug (Angio-Seal™) and suture-mediated (the Closer S™) closure devices at femoral access sites
    Park, Y
    Roh, HG
    Choo, SW
    Lee, SH
    Shin, SW
    Do, YS
    Byun, HS
    Park, KB
    Jeon, P
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2005, 6 (04) : 248 - 255
  • [10] Symptomatic vascular complications after vascular closure device use following diagnostic and interventional catheterisation
    Thalhammer, C
    Aschwanden, M
    Jeanneret, C
    Labs, KH
    Jäger, KA
    [J]. VASA-JOURNAL OF VASCULAR DISEASES, 2004, 33 (02): : 78 - 81