Energy saving potential of a vacuum-based membrane dehumidifier in a dedicated outdoor air system

被引:23
作者
Cheon, Seong-Yong [1 ]
Cho, Hye-Jin [1 ]
Jeong, Jae-Weon [1 ]
机构
[1] Hanyang Univ, Dept Architectural Engn, Coll Engn, 222 Wangsimni Ro, Seoul 04763, South Korea
基金
新加坡国家研究基金会;
关键词
Vacuum-based membrane dehumidifier; Dedicated outdoor air system; Isothermal dehumidification; Ventilation; Energy simulation; HEAT-PUMP; LIQUID DESICCANT; BINARY-MIXTURES; PERFORMANCE; EFFICIENCY; SEPARATION; WHEEL;
D O I
10.1016/j.enconman.2020.113618
中图分类号
O414.1 [热力学];
学科分类号
摘要
As a novel energy-conservative ventilation system for buildings, a dedicated outdoor air system (DOAS) assisted by a vacuum-based membrane dehumidifier is proposed, and its energy performance is investigated via detailed energy simulations. The vacuum-based membrane dehumidifier dries the air by an isothermal process, which is difficult to realize in conventional dehumidification systems. The proposed system consists of an enthalpy exchanger, a vacuum-based membrane dehumidifier, and a cooling coil. Its dehumidification performance and operation energy are compared with those of the following conventional DOASs: a DOAS that employs a cooling coil (Reference A) and a DOAS that employs an active desiccant wheel (Reference B). To evaluate the energy performance of the proposed system, the energy consumptions of all the DOASs were estimated by simulation programs (i.e., TRNSYS and EES) with mathematical models. The simulation results indicate that the average coefficient of performance of the DOAS we devised (i.e., 1.34) is lower than that of Reference A (i.e., 2.70) and higher than that of Reference B (i.e., 0.80). However, owing to the isothermal dehumidification process, the latent cooling ratio in the case of the proposed system (i.e., 1.0) is significantly higher than those in the cases of Reference A (i.e., 0.43) and Reference B (i.e., 0.11). Consequently, the annual energy consumption of the proposed system is 17.4% and 56.2% lower than those of Reference A and Reference B, respectively.
引用
收藏
页数:20
相关论文
共 44 条
[1]  
Agency KE, 2016, REG OPER BUILD ENERG
[2]   Performance assessment of cogeneration and trigeneration systems for small scale applications [J].
Angrisani, Giovanni ;
Akisawa, Atsushi ;
Marrasso, Elisa ;
Roselli, Carlo ;
Sasso, Maurizio .
ENERGY CONVERSION AND MANAGEMENT, 2016, 125 :194-208
[3]  
[Anonymous], 2013, Am. Soc. Heating, V2013, P278, DOI [10.1108/17506200710779521., DOI 10.1108/17506200710779521, 10.1108/17506200710779521]
[4]   Energy saving strategies in air-conditioning for museums [J].
Ascione, Fabrizio ;
Bellia, Laura ;
Capozzoli, Alfonso ;
Minichiello, Francesco .
APPLIED THERMAL ENGINEERING, 2009, 29 (04) :676-686
[5]  
ASHRAE, 2016, 6212016 ASHRAE
[6]  
ASHRAE, 2017, 55 ASHRAE, P12
[7]   Comparative field performance study of flat plate and heat pipe evacuated tube collectors (ETCs) for domestic water heating systems in a temperate climate [J].
Ayompe, L. M. ;
Duffy, A. ;
Mc Keever, M. ;
Conlon, M. ;
McCormack, S. J. .
ENERGY, 2011, 36 (05) :3370-3378
[8]   Energy efficiency of oxygen enriched air production technologies: Cryogeny vs membranes [J].
Belaissaoui, Bouchra ;
Le Moullec, Yann ;
Hagi, Hayato ;
Favre, Eric .
SEPARATION AND PURIFICATION TECHNOLOGY, 2014, 125 :142-150
[9]   A thermodynamic perspective to study energy performance of vacuum-based membrane dehumidification [J].
Bui, Duc Thuan ;
Ja, M. Kum ;
Gordon, Jeffrey M. ;
Ng, Kim Choon ;
Chua, Kian Jon .
ENERGY, 2017, 132 :106-115
[10]   On the theoretical and experimental energy efficiency analyses of a vacuum-based dehumidification membrane [J].
Bui, T. D. ;
Wong, Y. ;
Islam, M. R. ;
Chua, K. J. .
JOURNAL OF MEMBRANE SCIENCE, 2017, 539 :76-87