摘要
Oxygen-induced cerebrospinal fluid (CSF) hyperintensity artifact is inevitable in fluid attenuation inversion recovery (FLAIR) magnetic resonance (MR) images of anesthetized animals. This experimental study aimed to confirm the occurrence of this artifact on low-field magnetic resonance imaging (MRI), and to determine the fraction of inspired oxygen (FiO(2)) that is safe and does not induce this artifact in canine brain MRI. Six healthy dogs underwent brain FLAIR MR scans under general anesthesia with 21%, 30%, 50%, 70%, and 100% FiO(2). The signal intensity (SI) ratio was calculated as the SI of CSF spaces divided by that of normalizing regions. The SI ratios of 21% FiO(2) images were significantly different from those of 100% FiO(2) images, indicating the presence of artifacts on 100% FiO(2) images. The SI ratios of 30% FiO(2) images were not significantly different from those of 21% FiO(2) images for any of CSF spaces. However, they were significantly different from those of 100% FiO(2) images in the cerebral sulci, third ventricle, interpeduncular cistern, mesencephalic aqueduct, and subarachnoid space at the level of the first cervical vertebra (P<0.05). All dogs had normal partial pressure of arterial oxygen (PaO2) during inhalation of 30% FiO(2), while two dogs had low PaO2 during inhalation of 21% FiO(2). Our findings support the hypothesis that high FiO(2) induces CSF hyperintensity artifact on low-field FLAIR MR images in dogs. FiO(2) of 30% is appropriate for obtaining brain FLAIR MR images with fewer artifacts in dogs.
引用
收藏
页码:1321 / 1328
页数:8
相关论文
共 3 条
  • [1] Hyperintensity of Cerebrospinal Fluid on T2-Weighted Fluid-Attenuated Inversion Recovery Magnetic Resonance Imaging Caused by High Inspired Oxygen Fraction
    Moioli, Melania
    Levionnois, Olivier
    Stein, Veronika M.
    Schupbach, Gertraud
    Schmidhalter, Marta
    Schweizer-Gorgas, Daniela
    FRONTIERS IN VETERINARY SCIENCE, 2017, 4
  • [2] Comparison of magnetic resonance imaging sequences with computed tomography to detect low-grade subarachnoid hemorrhage - Role of fluid-attenuated inversion recovery sequence
    da Rocha, AJ
    da Silva, CJ
    Gama, HPP
    Baccin, CE
    Braga, FT
    Cesare, FD
    Veiga, JCE
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2006, 30 (02) : 295 - 303
  • [3] Evaluation of T2-weighted versus short-tau inversion recovery sagittal sequences in the identification and localization of canine intervertebral disc extrusion with low-field magnetic resonance imaging
    Housley, Daniel
    Caine, Abby
    Cherubini, Giunio
    Taeymans, Olivier
    VETERINARY RADIOLOGY & ULTRASOUND, 2017, 58 (04) : 433 - 443