Analytical Stability-Indicating Methods for Alogliptin in Tablets by LC-CAD and LC-UV

被引:7
|
作者
Bertol, Charise Dallazem [1 ,2 ]
Friedrich, Maria Tereza [3 ]
Carlos, Graciela [1 ]
Froehlich, Pedro Eduardo [1 ]
机构
[1] Univ Fed Rio Grande do Sul, Fac Farm, Lab Prod Subst Quim Referencia, Ave Ipiranga 2752, BR-90610000 Porto Alegre, RS, Brazil
[2] Univ Passo Fundo, Inst Ciencias Biol, Curso Farm, Lab Controle Qualidade, Campus 1,Km 292,BR 285, BR-99052900 Passo Fundo, RS, Brazil
[3] Univ Passo Fundo, Ctr Pesquisa Alimentacao, Lab Cromatog, Campus 1,Km 292,BR 285, BR-99052900 Passo Fundo, RS, Brazil
关键词
CHARGED-AEROSOL DETECTION; PERFORMANCE LIQUID-CHROMATOGRAPHY; PHARMACEUTICAL ANALYSIS; DETECTOR;
D O I
10.5740/jaoacint.16-0183
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Stability-indicating LC methods using a UV detector and a charged aerosol detector (CAD) simultaneously were validated for the assessment of alogliptin (ALG) in tablets. The analysis was performed on a C-8 column (250 x 4.6 mm, 5 mu m) at a flow of 0.8 mUmin, using acetonitrile-10 mM ammonium acetate buffer (pH 3.5; 90 + 10, v/v) as mobile phase and UV detection at 275 nm. Validation followed the International Conference on Harmonization guidelines. The method was linear over the range of 25-200 mu g/mL. Normality of the residuals showed a normal distribution, no autocorrelation, and homoscedasticity. LODs were 6.25 and 2.65 pg/mL and LOQs were 20.85 and 8.84 mu g/mL for the CAD and the UV detector, respectively. The methods were precise and accurate. Excipients and degradation products did not interfere in the methods in studies of specificity. None of the factors studied in the analysis of robustness had a significant effect on the quantification of the ALG by the Pareto chart. The results of the assay obtained with LC CAD and LC UV were similar. The methods could be considered interchangeable and stability indicating, and can be applied as an appropriate QC tool for analysis of ALG in tablets.
引用
收藏
页码:400 / 405
页数:6
相关论文
共 50 条
  • [41] Validation of a Stability Indicating LC-UV Method for [(N-Morpholine)methylene]daunorubicin Hydrochloride
    Anna Jelińska
    Marianna Zając
    Judyta Cielecka-Piontek
    Kinga Gląb
    Bartosz Tomaszewicz
    Anna Krause
    Irena Oszczapowicz
    Małgorzata Wąsowska
    Chromatographia, 2008, 67 : 107 - 111
  • [42] A Stability-Indicating LC Method for Assay of Topotecan Hydrochloride
    G. Saravanan
    M. V. Suryanarayana
    N. Balaji
    N. Someswararao
    N. M. Sekhar
    Chromatographia, 2008, 67 : 179 - 182
  • [43] Development and Validation of a Stability-Indicating LC Method for Curcumin
    Prajakta P. Dandekar
    Vandana B. Patravale
    Chromatographia, 2009, 69 : 871 - 877
  • [44] A Validated and Stability-Indicating LC Assay Method for Valdecoxib
    Raju, T. Satyanarayana
    Raghavachary, K. S. V.
    Reddy, A. Raghupathi
    Varma, M. Satish
    Ravikumar, M.
    Swamy, P. Yadagiri
    CHROMATOGRAPHIA, 2009, 69 (5-6) : 507 - 511
  • [45] STABILITY-INDICATING COMPARATIVE METHODS USING MEKC AND LC FOR DETERMINATION OF OLMESARTAN MEDOXOMIL
    Bajerski, Lisiane
    Paim, Clesio S.
    Pereira, Andrea G.
    Dias, Carolina L.
    Rossi, Rocheli C.
    Todeschini, Vitor
    Steppe, Martin
    Bergold, Ana Maria
    Froeehlich, Pedro E.
    QUIMICA NOVA, 2013, 36 (01): : 34 - 39
  • [46] A Validated and Stability-Indicating LC Assay Method for Valdecoxib
    T. Satyanarayana Raju
    K. S. V. Raghavachary
    A. Raghupathi Reddy
    M. Satish Varma
    M. Ravikumar
    P. Yadagiri Swamy
    Chromatographia, 2009, 69 : 507 - 511
  • [47] A stability-indicating LC assay method for pemetrexed disodium
    Saravanan, G.
    Suryanarayana, M. V.
    Jadhav, M. J.
    Ravikumar, M.
    Someswararao, N.
    Acharulu, P. V. R.
    CHROMATOGRAPHIA, 2007, 66 (5-6) : 431 - 434
  • [48] A validated, stability-indicating, LC method for rabeprazole sodium
    Buchireddy, Reguri
    Mukkanti, Khagga
    Srinivasulu, Polisetty
    Srinivas, Koduri S. V.
    CHROMATOGRAPHIA, 2008, 68 (3-4) : 275 - 280
  • [49] A stability-indicating LC method for assay of topotecan hydrochloride
    Saravanan, G.
    Suryanarayana, M. V.
    Balaji, N.
    Someswararao, N.
    Sekhar, N. M.
    CHROMATOGRAPHIA, 2008, 67 (1-2) : 179 - 182
  • [50] Development and Validation of a Stability-Indicating LC Method for Curcumin
    Dandekar, Prajakta P.
    Patravale, Vandana B.
    CHROMATOGRAPHIA, 2009, 69 (9-10) : 871 - 877