Analytical Stability-Indicating Methods for Alogliptin in Tablets by LC-CAD and LC-UV

被引:7
|
作者
Bertol, Charise Dallazem [1 ,2 ]
Friedrich, Maria Tereza [3 ]
Carlos, Graciela [1 ]
Froehlich, Pedro Eduardo [1 ]
机构
[1] Univ Fed Rio Grande do Sul, Fac Farm, Lab Prod Subst Quim Referencia, Ave Ipiranga 2752, BR-90610000 Porto Alegre, RS, Brazil
[2] Univ Passo Fundo, Inst Ciencias Biol, Curso Farm, Lab Controle Qualidade, Campus 1,Km 292,BR 285, BR-99052900 Passo Fundo, RS, Brazil
[3] Univ Passo Fundo, Ctr Pesquisa Alimentacao, Lab Cromatog, Campus 1,Km 292,BR 285, BR-99052900 Passo Fundo, RS, Brazil
关键词
CHARGED-AEROSOL DETECTION; PERFORMANCE LIQUID-CHROMATOGRAPHY; PHARMACEUTICAL ANALYSIS; DETECTOR;
D O I
10.5740/jaoacint.16-0183
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Stability-indicating LC methods using a UV detector and a charged aerosol detector (CAD) simultaneously were validated for the assessment of alogliptin (ALG) in tablets. The analysis was performed on a C-8 column (250 x 4.6 mm, 5 mu m) at a flow of 0.8 mUmin, using acetonitrile-10 mM ammonium acetate buffer (pH 3.5; 90 + 10, v/v) as mobile phase and UV detection at 275 nm. Validation followed the International Conference on Harmonization guidelines. The method was linear over the range of 25-200 mu g/mL. Normality of the residuals showed a normal distribution, no autocorrelation, and homoscedasticity. LODs were 6.25 and 2.65 pg/mL and LOQs were 20.85 and 8.84 mu g/mL for the CAD and the UV detector, respectively. The methods were precise and accurate. Excipients and degradation products did not interfere in the methods in studies of specificity. None of the factors studied in the analysis of robustness had a significant effect on the quantification of the ALG by the Pareto chart. The results of the assay obtained with LC CAD and LC UV were similar. The methods could be considered interchangeable and stability indicating, and can be applied as an appropriate QC tool for analysis of ALG in tablets.
引用
收藏
页码:400 / 405
页数:6
相关论文
共 50 条
  • [21] ESI-MSn and LC-ESI-MS studies to characterize forced degradation products of bosentan and a validated stability-indicating LC-UV method
    Bansal, Gulshan
    Singh, Ranjit
    Saini, Balraj
    Bansal, Yogita
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 72 : 186 - 197
  • [22] Development and Validation of a Stability-Indicating LC Method for the Assay of Lodenafil Carbonate in Tablets
    Codevilla, Cristiane Franco
    Lemos, Alice Machado
    Delgado, Leila Schreiner
    Bueno Rolim, Clarice Madalena
    Horn Adams, Andrea Ines
    Bergold, Ana Maria
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2011, 49 (07) : 502 - 507
  • [23] Stability-Indicating LC Method for Assay of Cholecalciferol
    Desai, Namita D.
    Singh, Pirthipal P.
    Amin, Purnima D.
    Jain, Satishkumar P.
    CHROMATOGRAPHIA, 2009, 69 (3-4) : 385 - 388
  • [24] Stability-Indicating LC Method for Assay of Cholecalciferol
    Namita D. Desai
    Pirthipal P. Singh
    Purnima D. Amin
    Satishkumar P. Jain
    Chromatographia, 2009, 69 : 385 - 388
  • [25] A Stability-Indicating LC Assay Method for Bicalutamide
    G. Saravanan
    B. M. Rao
    M. Ravikumar
    M. V. Suryanarayana
    N. Someswararao
    P. V. R. Acharyulu
    Chromatographia, 2007, 66 : 219 - 222
  • [26] A stability-indicating LC assay method for bicalutamide
    Saravanan, G.
    Rao, B. M.
    Ravikumar, M.
    Suryanarayana, M. V.
    Someswararao, N.
    Acharyulu, P. V. R.
    CHROMATOGRAPHIA, 2007, 66 (3-4) : 219 - 222
  • [27] A validated stability-indicating LC method for zonisamide
    Pathare, Dnyandeo B.
    Jadhav, Ashok S.
    Shinqare, Murlidhar S.
    CHROMATOGRAPHIA, 2007, 66 (11-12) : 945 - 947
  • [28] A Validated Stability-Indicating LC Method for Zonisamide
    Dnyandeo B. Pathare
    Ashok S. Jadhav
    Murlidhar S. Shingare
    Chromatographia, 2007, 66 : 945 - 947
  • [29] A stability-indicating LC method for candesartan cilexetil
    Rao, D. V. Subba
    Radhakrishnanand, P.
    Suranarayana, M. V.
    Himabindu, V.
    CHROMATOGRAPHIA, 2007, 66 (7-8) : 499 - 507
  • [30] A Stability-Indicating LC Method for Candesartan Cilexetil
    D. V. Subba Rao
    P. Radhakrishnanand
    M. V. Suryanarayana
    V. Himabindu
    Chromatographia, 2007, 66 : 499 - 507