Determination of sterols using liquid chromatography with off-line surface-assisted laser desorption/ionization mass spectrometry

被引:15
作者
Vrbkova, Blanka [1 ]
Roblova, Vendula [1 ]
Yeung, Edward S. [2 ]
Preisler, Jan [1 ,3 ]
机构
[1] Masaryk Univ, Fac Sci, Dept Chem, Brno 62500, Czech Republic
[2] Iowa State Univ, Dept Chem, Ames, IA 50011 USA
[3] Masaryk Univ, Cent European Inst Technol CEITEC, Brno 62500, Czech Republic
关键词
Sterols; Oil sample; SALDI MS; RPLC; Off-line coupling; Silver nanoparticles; DESORPTION-IONIZATION; SILVER NANOPARTICLES; SYNTHETIC-POLYMERS; PHYTOSTEROLS; OILS; MS; EXTRACTION; SEPARATION; ELECTROPHORESIS; BIOMOLECULES;
D O I
10.1016/j.chroma.2014.06.077
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new method, reversed phase liquid chromatography with off-line surface-assisted laser desorption/ionization mass spectrometry (RPLC-SALDI MS) for the determination of brassicasterol (BR), cholesterol (CH), stigmasterol (ST), campesterol (CA) and beta-sitosterol (SI) in oil samples has been developed. The sample preparation consisted of alkaline saponification followed by extraction of the unsaponificable fraction with diethyl ether. The recovery of the sterols ranged from 91 to 95% with RSD less than 4%. Separation of the five major sterols on a C18 column using methanol-water gradient was achieved in about 10 min. An on-line UV detector was employed for the initial sterol detection prior to effluent deposition using a laboratory-built spotter with 1:73 splitter. Off-line SALDI MS was then applied for mass determination/identification and quantification of the separated sterols. Ionization of the nonpolar analytes was achieved by silver ion cationization with silver nanoparticles used as the SALDI matrix providing limits of detection 12,6 and 11 fmol for CH, ST and SI, respectively. Because of the incorporated splitter, the effective limits of detection of the RPLC-SALDI MS analysis were 4,3 and 4 pmol (or 0.08, 0.06 and 0.08 mu g/mL) for CH, ST and SI, respectively. For quantification, 6-ketocholestanol (KE) was used as the internal standard. The method has been applied for the identification and quantification of sterols in olive, linseed and sunflower oil samples. The described off-line coupling of RPLC to SALDI MS represents an alternative to GC-MS for analysis of nonpolar compounds. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:102 / 109
页数:8
相关论文
共 48 条
[1]  
BLIGH EG, 1959, CAN J BIOCHEM PHYS, V37, P911
[2]   Concept of sequential analysis of free and conjugated phytosterols in different plant matrices [J].
Breinhölder, P ;
Mosca, L ;
Lindner, W .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 777 (1-2) :67-82
[3]   Separation and determination of sterols in olive oil by HPLC-MS [J].
Canabate-Diaz, B. ;
Segura Carretero, A. ;
Fernandez-Gutierrez, A. ;
Belmonte Vega, A. ;
Garrido Frenich, A. ;
Martinez Vidal, J. L. ;
Duran Martos, J. .
FOOD CHEMISTRY, 2007, 102 (03) :593-598
[4]   Liquid chromatography-UV determination and liquid chromatography-atmospheric pressure chemical ionization mass spectrometric characterization of sitosterol and stigmasterol in soybean oil [J].
Careri, M ;
Elviri, L ;
Mangia, A .
JOURNAL OF CHROMATOGRAPHY A, 2001, 935 (1-2) :249-257
[5]   Fe3O4/TiO2 core/shell nanoparticles as affinity probes for the analysis of phosphopeptides using TiO2 surface-assisted laser desorption/ionization mass spectrometry [J].
Chen, CT ;
Chen, YC .
ANALYTICAL CHEMISTRY, 2005, 77 (18) :5912-5919
[6]  
Chen WT, 2011, J CHIN CHEM SOC-TAIP, V58, P769
[7]   Laser desorption/ionization from nanostructured surfaces: nanowires, nanoparticle films and silicon microcolumn arrays [J].
Chen, Yong ;
Luo, Guanghong ;
Diao, Jiajie ;
Chornoguz, Olesya ;
Reeves, Mark ;
Vertes, Akos .
COLA'05: 8TH INTERNATIONAL CONFERENCE ON LASER ABLATION, 2007, 59 :548-+
[8]   Determining estrogens using surface-assisted laser desorption/ionization mass spectrometry with silver nanoparticles as the matrix [J].
Chiu, Tai-Chia ;
Chang, Lin-Chau ;
Chiang, Cheng-Kang ;
Chang, Huan-Tsung .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2008, 19 (09) :1343-1346
[9]   Graphite/liquid mixed matrices for laser desorption/ionization mass spectrometry [J].
Dale, MJ ;
Knochenmuss, R ;
Zenobi, R .
ANALYTICAL CHEMISTRY, 1996, 68 (19) :3321-3329
[10]   Improved MALDI-MS analysis of oligonucleotides through the use of fucose as a matrix additive [J].
Distler, AM ;
Allison, J .