Almost complete colour constancy achieved with full-field adaptation

被引:29
|
作者
Murray, I. J.
Daugirdiene, A.
Vaitkevicius, H.
Kulikowski, J. J.
Stanikunas, R.
机构
[1] Univ Manchester, Fac Life Sci, Manchester M60 1QD, Lancs, England
[2] Vilnius State Univ, Dept Psychol & Didact, LT-08106 Vilnius, Lithuania
[3] Vilnius State Univ, Fac Philosophy, Dept Gen Psychol, LT-01513 Vilnius, Lithuania
[4] Vilnius State Univ, Inst Mat & Appl Sci, LT-2040 Vilnius, Lithuania
关键词
simulated Munsell samples; colour constancy; colour-matching; duration; large field;
D O I
10.1016/j.visres.2006.03.011
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
A successive asymmetric colour-matching task was used to study the changes in colour appearance of simulated Munsell samples. Colour shifts were induced with two Planckian illuminants, standard illuminant A (u' = 0.256, v' = 0.524) and illuminant S u' = 0.174, v' = 0.392). Measurements were conducted with a 200 field and a 120 degrees field. Adaptation period varied from 1 to 30 s with the smaller field and from 1 to 60 s with the larger field. Colour shifts were specified in terms of a modified Brunswik ratio (BR). Higher values of BR were associated with longer adaptation periods but only when the larger background was used. Supplementary experiments showed that the changes in colour appearance were related to a slight shift in the perceived colour of the background. The timing of the colour shifts are modelled in terms of cone opponent responses. High values of BR correspond to almost complete von Kries adaptation in all three cone types. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3067 / 3078
页数:12
相关论文
共 50 条
  • [31] Standardized full-field electroretinography in rabbits
    Karin Gjörloff
    Sten Andréasson
    Berndt Ehinger
    Documenta Ophthalmologica, 2004, 109 : 163 - 168
  • [32] FULL-FIELD DIFFRACTION PARTICLE SIZING
    COIL, MA
    FARRELL, PV
    APPLIED OPTICS, 1995, 34 (33): : 7771 - 7786
  • [33] Calibration and validation of full-field techniques
    Hack, E.
    Patterson, E.
    Siebert, T.
    Thalmann, R.
    ICEM 14: 14TH INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS, VOL 6, 2010, 6
  • [34] Full-field quantitative phase imaging
    DiMarzio, Charles A.
    THREE-DIMENSIONAL AND MULTIDIMENSIONAL MICROSCOPY: IMAGE ACQUISITION AND PROCESSING XV, 2008, 6861
  • [35] Full-field functional optical angiography
    Wang, Mingyi
    Mao, Wenjian
    Guan, Caizhong
    Feng, Guanping
    Tan, Haishu
    Han, Dingan
    Zeng, Yaguang
    OPTICS LETTERS, 2017, 42 (03) : 635 - 638
  • [36] TOWARDS A FULL-FIELD COMPENSATION METHOD
    CERNOSEK, J
    EXPERIMENTAL MECHANICS, 1972, 12 (03) : 152 - &
  • [37] Recording of the full-field electroretinogram in minipigs
    Augsburger, Anne-Sandrine
    Haag, Valerie
    Leuillet, Sebastien
    Legrand, Jean-Jacques
    Forster, Roy
    VETERINARY OPHTHALMOLOGY, 2012, 15 : 84 - 93
  • [38] NEW METHOD FOR FULL-FIELD DIFFERENTIATION
    SEGALMAN, DJ
    WOYAK, DB
    ROWLANDS, RE
    EXPERIMENTAL MECHANICS, 1979, 19 (05) : N43 - N43
  • [39] FULL-FIELD SYSTEM FOR CLINICAL ELECTRORETINOGRAPHY
    RABIN, AR
    BERSON, EL
    ARCHIVES OF OPHTHALMOLOGY, 1974, 92 (01) : 59 - 63
  • [40] Full-field perimetry in pituitary tumors
    Venugopal, N.
    NEUROLOGY INDIA, 2017, 65 (03)