Frequency Function in Atomic Force Microscopy Applied to a Liquid Environment

被引:10
作者
Shih, Po-Jen [1 ]
机构
[1] Natl Univ Kaohsiung, Dept Civil & Environm Engn, CEE NUK, Kaohsiung 81148, Taiwan
关键词
frequency shift function; jump to contact; liquid environment; atomic force microscopy; VISCOUS-FLUID; PROBES; RESOLUTION; SURFACE; WALL;
D O I
10.3390/s140609369
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Scanning specimens in liquids using commercial atomic force microscopy (AFM) is very time-consuming due to the necessary try-and-error iteration for determining appropriate triggering frequencies and probes. In addition, the iteration easily contaminates the AFM tip and damages the samples, which consumes probes. One reason for this could be inaccuracy in the resonant frequency in the feedback system setup. This paper proposes a frequency function which varies with the tip-sample separation, and it helps to improve the frequency shift in the current feedback system of commercial AFMs. The frequency function is a closed-form equation, which allows for easy calculation, as confirmed by experimental data. It comprises three physical effects: the quasi-static equilibrium condition, the atomic forces gradient effect, and hydrodynamic load effect. While each of these has previously been developed in separate studies, this is the first time their combination has been used to represent the complete frequency phenomenon. To avoid "jump to contact" issues, experiments often use probes with relatively stiffer cantilevers, which inevitably reduce the force sensitivity in sensing low atomic forces. The proposed frequency function can also predict jump to contact behavior and, thus, the probe sensitivity could be increased and soft probes could be widely used. Additionally, various tip height behaviors coupling with the atomic forces gradient and hydrodynamic effects are discussed in the context of carbon nanotube probes.
引用
收藏
页码:9369 / 9379
页数:11
相关论文
共 23 条
[1]   Single-step direct measurement of amyloid fibrils stiffness by peak force quantitative nanomechanical atomic force microscopy [J].
Adamcik, Jozef ;
Berquand, Alexandre ;
Mezzenga, Raffaele .
APPLIED PHYSICS LETTERS, 2011, 98 (19)
[2]   FREQUENCY-MODULATION DETECTION USING HIGH-Q CANTILEVERS FOR ENHANCED FORCE MICROSCOPE SENSITIVITY [J].
ALBRECHT, TR ;
GRUTTER, P ;
HORNE, D ;
RUGAR, D .
JOURNAL OF APPLIED PHYSICS, 1991, 69 (02) :668-673
[3]  
Clough R. W., 2003, DYNAMICS STRUCTURES, P370
[4]  
Fukuma T, 2009, NANOSCI TECHNOL, V2, P329, DOI 10.1007/978-3-642-01495-6_16
[5]   Forces and frequency shifts in atomic-resolution dynamic-force microscopy [J].
Giessibl, FJ .
PHYSICAL REVIEW B, 1997, 56 (24) :16010-16015
[6]   ATOMIC-RESOLUTION OF THE SILICON (111)-(7X7) SURFACE BY ATOMIC-FORCE MICROSCOPY [J].
GIESSIBL, FJ .
SCIENCE, 1995, 267 (5194) :68-71
[7]   A direct method to calculate tip-sample forces from frequency shifts in frequency-modulation atomic force microscopy [J].
Giessibl, FJ .
APPLIED PHYSICS LETTERS, 2001, 78 (01) :123-125
[8]   Determination of tip-sample interaction forces from measured dynamic force spectroscopy curves [J].
Gotsmann, B ;
Anczykowski, B ;
Seidel, C ;
Fuchs, H .
APPLIED SURFACE SCIENCE, 1999, 140 (3-4) :314-319
[9]   Small amplitude oscillations of a thin beam immersed in a viscous fluid near a solid surface [J].
Green, CP ;
Sader, JE .
PHYSICS OF FLUIDS, 2005, 17 (07) :1-12
[10]   Force microscopy with light-atom probes [J].
Hembacher, S ;
Giessibl, FJ ;
Mannhart, J .
SCIENCE, 2004, 305 (5682) :380-383