Micro gas turbine cogeneration system with latent heat storage at the University: Part II: Part load and thermal priority mode

被引:12
作者
Kurata, Osamu [1 ]
Iki, Norihiko [1 ]
Matsunuma, Takayuki [1 ]
Maeda, Tetsuhiko [2 ]
Hirano, Satoshi [3 ]
Kadoguchi, Katsuhiko [4 ]
Takeuchi, Hiromi [4 ]
Yoshida, Hiro [5 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Energy Technol Res Inst, Turbomachinery Grp, Tsukuba, Ibaraki 3058564, Japan
[2] Natl Inst Adv Ind Sci & Technol, Energy Technol Res Inst, Socioecon & Policy Study Grp, Tsukuba, Ibaraki 3058564, Japan
[3] Natl Inst Adv Ind Sci & Technol, Energy Technol Res Inst, Thermal & Fluid Syst Grp, Tsukuba, Ibaraki 3058569, Japan
[4] Natl Inst Adv Ind Sci & Technol, Energy Technol Res Inst, Tsukuba, Ibaraki 305, Japan
[5] Kanagawa Inst Technol, Dept Vehicle Syst Engn, Atsugi, Kanagawa 2430292, Japan
关键词
Cogeneration system; Micro gas turbine; Latent heat storage; Phase-change material; University; Energy flow; Part-load operation; Thermal priority mode; Programmable logic controller; PERFORMANCE ANALYSIS; POWER; MICROTURBINE; OPERATION;
D O I
10.1016/j.applthermaleng.2013.12.050
中图分类号
O414.1 [热力学];
学科分类号
摘要
A good cogeneration system should have high efficiency and good coordination. A micro gas turbine cogeneration system with latent heat storage was demonstrated at the University. Since there had been no cogeneration system with the latent heat storage under service condition, this system was the first demonstration and its characteristic was very important. The proper use of the latent heat storage system will save energy economically, store high energy density, reduce exhaust emissions, and save operational costs. A heat exchanger and an economizer were located in parallel downstream of a bypass dumper for exhaust gas. The latent heat storage tank was located downstream of the economizer. The bypass dumper released exhaust gas when the boiler water in the heat exchanger exceeded 90 C. It is very important to use the heat supply of hot water as much as possible. At the University, the winter term heat demand from 6 pm to 7 pm was somewhat less than that from 8 am to 6 pm in 2010. We conducted a part-load operation from 6 pm to 7 pm to observe how it would respond to the heat demand. The heat supply from the cogeneration system during this time period was controllable with the heat storage. The heat supply from the system at the lowest power setting was larger than the heat demand, and thus was uncontrollable without heat storage. In Part I [1], a fixed operating schedule of the system was planned and demonstrated at the University. Total 407 charge/discharge cycles of the latent heat storage were repeated. The energy flow test of the system shows the importance of heat release source and total system design. In Part III [2], a temperature control schedule of the system was demonstrated in winter morning using a new programmable logic controller (PLC). If the more larger latent heat storage system will be developed in the future, it will be expected greatly that the temperature of the classrooms are kept more comfortable with less energy consumptions and less CO2 emission. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:246 / 254
页数:9
相关论文
共 32 条
  • [1] Andrews G.E., 1999, GTSJ P INT GAS TURB, P793
  • [2] Bahr D.W., 1999, GTSJ P INT GAS TURB, P15
  • [3] Effect of ambient temperature on the performance of micro gas turbine with cogeneration system in cold region
    Basrawi, Firdaus
    Yamada, Takanobu
    Nakanishi, Kimio
    Naing, Soe
    [J]. APPLIED THERMAL ENGINEERING, 2011, 31 (6-7) : 1058 - 1067
  • [4] Use of a test-bed to study the performance of micro gas turbines for cogeneration applications
    Caresana, Flavio
    Comodi, Gabriele
    Pelagalli, Leonardo
    Renzi, Massimiliano
    Vagni, Sandro
    [J]. APPLIED THERMAL ENGINEERING, 2011, 31 (16) : 3552 - 3558
  • [5] Experimentation on a cogenerative system based on a microturbine
    Colombo, Luigi P. M.
    Armanasco, Fabio
    Perego, Omar
    [J]. APPLIED THERMAL ENGINEERING, 2007, 27 (04) : 705 - 711
  • [6] Micro-combined heat and power in residential and light commercial applications
    d'Accadia, MD
    Sasso, M
    Sibilio, S
    Vanoli, L
    [J]. APPLIED THERMAL ENGINEERING, 2003, 23 (10) : 1247 - 1259
  • [7] Energy, economic and environmental (3E) analysis of a micro gas turbine employed for on-site combined heat and power production
    Ehyaei, M. A.
    Mozafari, A.
    [J]. ENERGY AND BUILDINGS, 2010, 42 (02) : 259 - 264
  • [8] Influences of thermal and electric load fluctuations in the cogeneration attractiveness
    Ernst, Mario A. Basulto
    Balestieri, Jose A. Perrella
    [J]. APPLIED THERMAL ENGINEERING, 2006, 26 (14-15) : 1500 - 1505
  • [9] Greenhouse Gas Technology Center Southern Research Institute EPA, 2003, ENV TECHN VER REP CO
  • [10] Gas turbines in district heating combined heat and power systems: influence of performance on heating costs and emissions
    Harvey, S
    Carcasci, C
    Berntsson, T
    [J]. APPLIED THERMAL ENGINEERING, 2000, 20 (12) : 1075 - 1103