Comparison of the macintosh and airtraq laryngoscopes in morbidly obese patients: a randomized and prospective study

被引:22
作者
Castillo-Monzon, Caridad G. [1 ]
Marroquin-Valz, Hugo A. [1 ]
Fernandez-Villacanas-Marin, Miguel [1 ]
Moreno-Cascales, Matilde [1 ]
Garcia-Rojo, Blas [1 ]
Candia-Arana, Cesar A. [1 ]
机构
[1] Univ Gen Hosp Cartagena, Serv Anesthesiol Reanimat & Pain Therapy, Murcia, Spain
关键词
Airtraq laryngoscope; Airway management; Macintosh laryngoscope; Video laryngoscopes; DIFFICULT TRACHEAL INTUBATION; BODY-MASS INDEX; AIRWAY MANAGEMENT; NECK CIRCUMFERENCE; GASTRIC BYPASS; CLASSIFICATION; PREDICTORS; ANESTHESIA; RISK;
D O I
10.1016/j.jclinane.2016.10.023
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Study objective: Morbid obesity is associated with a difficult management of the airway. There is no agreement on these patients being difficult to intubate, but if they are difficult to ventilate with facial mask, then the fast control of their airway becomes a priority. This study compares the quickness and success in tracheal intubation, glottic view, hemodynamic response, and complications from the use of the Macintosh and Airtraq laryngoscopes in morbidly obese patients for scheduled surgery. Design: Prospective, observational, and randomized study. Setting: Operating room. Patients: Forty-six American Society of Anesthesiologists III patients. Interventions: Patients were randomly assigned to undergo tracheal intubation using a Macintosh (n = 23) or an Airtraq laryngoscope (n = 23). Measurements: The following were compared: intubation time, laryngeal vision, the necessity of additional maneuvers to carry out the tracheal intubation, the success of the maneuvers, complications, and hemodynamic response. Main results: The preoperative conditions of the studied patients were similar in both groups. The average time of the intubation was 17.27 +/- 16.1 seconds and 22.11 +/- 13.62 seconds in the Airtraq and Macintosh groups, respectively (P=.279). With the Airtraq device, 95.65% of patients presented a glottic view 1 and 2a (P=.006) and less optimizing maneuvers were needed to perform the tracheal intubation (P=.001). There were no cases of difficult intubation, failed intubation, or difficult ventilation. A statistically significant increase in the heart rate was detected with the use of the Macintosh laryngoscope. A patient with redundant epiglottis could not be intubated with the Airtraq laryngoscope. Conclusion: Both devices allow quick and safe management of the airway. The Airtraq laryngoscope improved the glottic view by the modified Cormack-Lehane classification, reduced the need for additional maneuvers for tracheal intubation, and also reduced the degree of sympathetic stimulus detected by a minor increase in heart rate after tracheal intubation. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:136 / 141
页数:6
相关论文
共 37 条
[1]   An Algorithm for Difficult Airway Management, Modified for Modern Optical Devices (Airtraq Laryngoscope; LMA CTrach™) A 2-Year Prospective Validation in Patients for Elective Abdominal, Gynecologic, and Thyroid Surgery [J].
Amathieu, Roland ;
Combes, Xavier ;
Abdi, Widad ;
El Housseini, Loutfi ;
Rezzoug, Ahmed ;
Dinca, Andrei ;
Slavov, Velislav ;
Bloc, Sebastien ;
Dhonneur, Gilles .
ANESTHESIOLOGY, 2011, 114 (01) :25-33
[2]   Practice Guidelines for Management of the Difficult Airway An Updated Report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway [J].
Apfelbaum J.L. ;
Hagberg C.A. ;
Caplan R.A. ;
Connis R.T. ;
Nickinovich D.G. ;
Benumof J.L. ;
Berry F.A. ;
Blitt C.D. ;
Bode R.H. ;
Cheney F.W. ;
Guidry O.F. ;
Ovassapian A. .
ANESTHESIOLOGY, 2013, 118 (02) :251-270
[3]   Fast-track surgery for bariatric laparoscopic gastric bypass with focus on anaesthesia and peri-operative care. Experience with 500 cases [J].
Bergland, A. ;
Gislason, H. ;
Raeder, J. .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2008, 52 (10) :1394-1399
[4]   Morbid obesity and tracheal intubation [J].
Brodsky, JB ;
Lemmens, HJM ;
Brock-Utne, JG ;
Vierra, M ;
Saidman, LJ .
ANESTHESIA AND ANALGESIA, 2002, 94 (03) :732-736
[5]  
Budde Arne O, 2013, J Anaesthesiol Clin Pharmacol, V29, P183, DOI 10.4103/0970-9185.111685
[6]  
Caplan RA, 2003, ANESTHESIOLOGY, V98, P1269
[7]   An Evaluation of the Rapid Airway Management Positioner in Obese Patients Undergoing Gastric Bypass or Laparoscopic Gastric Banding Surgery [J].
Cattano, Davide ;
Melnikov, Vladimir ;
Khalil, Yameen ;
Sridhar, Srikanth ;
Hagberg, Carin A. .
OBESITY SURGERY, 2010, 20 (10) :1436-1441
[8]  
Chalkeidis Omiros, 2010, Acta Anaesthesiol Taiwan, V48, P15, DOI 10.1016/S1875-4597(10)60004-5
[9]   A new practical classification of laryngeal view [J].
Cook, TM .
ANAESTHESIA, 2000, 55 (03) :274-279
[10]   A comparison of two techniques for inserting the Airtraq™ laryngoscope in morbidly obese patients [J].
Dhonneur, G. ;
Ndoko, S. K. ;
Amathieu, R. ;
Attias, A. ;
Housseini, L. E. L. ;
Polliand, C. ;
Tual, L. .
ANAESTHESIA, 2007, 62 (08) :774-777