Methylene green voltammetry in aqueous solution: Studies using thermal, microwave, laser, or ultrasonic activation at platinum electrodes

被引:44
作者
Akkermans, RP [1 ]
Roberts, SL [1 ]
Marken, F [1 ]
Coles, BA [1 ]
Wilkins, SJ [1 ]
Cooper, JA [1 ]
Woodhouse, KE [1 ]
Compton, RG [1 ]
机构
[1] Univ Oxford, Phys & Theoret Chem Lab, Oxford OX1 3QZ, England
关键词
D O I
10.1021/jp992164b
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The voltammetry of the aqueous two-electron reduction of the phenothiazine dye methylene green, known to be passivating at platinum electrodes, is reported under simultaneous activation with each of the following techniques: thermal activation in the temperature range 15-80 degrees C, pulsed microwave activation with a modified 800 W, 2.45 GHz domestic microwave oven, 10 Hz pulsed laser activation with a Nd:YAG laser at 532 nm, sonication, or ultrasonic activation where a 20 kHz ultrasonic horn probe is employed to generate an aqueous/organic solvent emulsion. The relative merits of the five methodologies are compared and discussed in terms of surface activation and cleaning, mass-transport enhancement, and reduction mechanism elucidation. Comparisons are also drawn with the voltammetry of methylene blue, a dye of the same family. This is the first full report of both the effects of microwave heating on surface redox electrochemistry and of the sonoemulsion technique.
引用
收藏
页码:9987 / 9995
页数:9
相关论文
共 53 条
[1]   Ultrasonic effects on electroorganic processes. Cavitation threshold values of ultrasound-oscillating power [J].
Atobe, M ;
Nonaka, T .
CHEMISTRY LETTERS, 1997, (04) :323-324
[2]  
Brett AMO, 1997, ULTRASON SONOCHEM, V4, P123
[3]   ELECTRON-TRANSFER KINETICS AT MODIFIED CARBON ELECTRODE SURFACES - THE ROLE OF SPECIFIC SURFACE SITES [J].
CHEN, PH ;
FRYLING, MA ;
MCCREERY, RL .
ANALYTICAL CHEMISTRY, 1995, 67 (18) :3115-3122
[4]   Control of electron transfer kinetics at glassy carbon electrodes by specific surface modification [J].
Chen, PH ;
McCreery, RL .
ANALYTICAL CHEMISTRY, 1996, 68 (22) :3958-3965
[5]   ELECTROCATALYTIC OXIDATION OF REDUCED NICOTINAMIDE COENZYMES AT METHYLENE GREEN-MODIFIED ELECTRODES AND FABRICATION OF AMPEROMETRIC ALCOHOL BIOSENSORS [J].
CHI, QJ ;
DONG, SJ .
ANALYTICA CHIMICA ACTA, 1994, 285 (1-2) :125-133
[6]   Self-assembly of methylene blue at single-crystal platinum electrodes modified by sulphur adlayer [J].
Clavilier, J ;
Svetlicic, V ;
Zutic, V .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 402 (1-2) :129-135
[7]   Ohmic distortion of mass transport and of current-voltage curves at a channel electrode [J].
Coles, BA ;
Compton, RG ;
Larsen, JP ;
Spackman, RA .
ELECTROANALYSIS, 1996, 8 (10) :913-917
[8]   Sonoelectrochemical processes: A review [J].
Compton, RG ;
Eklund, JC ;
Marken, F .
ELECTROANALYSIS, 1997, 9 (07) :509-522
[9]   VOLTAMMETRY IN THE PRESENCE OF ULTRASOUND - SONOVOLTAMMETRY AND SURFACE EFFECTS [J].
COMPTON, RG ;
EKLUND, JC ;
PAGE, SD ;
SANDERS, GHW ;
BOOTH, J .
JOURNAL OF PHYSICAL CHEMISTRY, 1994, 98 (47) :12410-12414
[10]  
COMPTON RG, 1995, PROG REACT KINET MEC, V20, P245