A novel single-ended readout depth-of-interaction PET detector fabricated using sub-surface laser engraving

被引:40
|
作者
Uchida, H. [1 ]
Sakai, T. [1 ]
Yamauchi, H. [1 ]
Hakamata, K. [1 ]
Shimizu, K. [1 ]
Yamashita, T. [1 ]
机构
[1] Hamamatsu Photon KK, Dev Ctr, Hamakita Ku, Hamamatsu, Shizuoka 4348601, Japan
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 18期
关键词
depth of interaction; laser processing; PET detector; scintillator; MULTICRYSTAL DETECTORS; ANIMAL PET; SCINTILLATOR; DESIGN; ARRAY; DOI; RESOLUTION; MODULE; DIRECTIONS; SIMULATION;
D O I
10.1088/0031-9155/61/18/6635
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We propose a novel scintillation detector design for positron emission tomography (PET), which has depth of interaction (DOI) capability and uses a single-ended readout scheme. The DOI detector contains a pair of crystal bars segmented using sub-surface laser engraving (SSLE). The two crystal bars are optically coupled to each other at their top segments and are coupled to two photo-sensors at their bottom segments. Initially, we evaluated the performance of different designs of single crystal bars coupled to photomultiplier tubes at both ends. We found that segmentation by SSLE results in superior performance compared to the conventional method. As the next step, we constructed a crystal unit composed of a 3 x 3 x 20 mm(3) crystal bar pair, with each bar containing four layers segmented using the SSLE. We measured the DOI performance by changing the optical conditions for the crystal unit. Based on the experimental results, we then assessed the detector performance in terms of the DOI capability by evaluating the position error, energy resolution, and light collection efficiency for various crystal unit designs with different bar sizes and a different number of layers (four to seven layers). DOI encoding with small position error was achieved for crystal units composed of a 3 x 3 x 20 mm3 LYSO bar pair having up to seven layers, and with those composed of a 2 x 2 x 20 mm3 LYSO bar pair having up to six layers. The energy resolution of the segment in the seven-layer 3 x 3 x 20 mm3 crystal bar pair was 9.3%-15.5% for 662 keV gamma-rays, where the segments closer to the photo-sensors provided better energy resolution. SSLE provides high geometrical accuracy at low production cost due to the simplicity of the crystal assembly. Therefore, the proposed DOI detector is expected to be an attractive choice for practical small-bore PET systems dedicated to imaging of the brain, breast, and small animals.
引用
收藏
页码:6635 / 6650
页数:16
相关论文
共 50 条
  • [1] Performance evaluation of continuous depth-of-interaction encoding PET detector using a single-ended readout
    Ito, Mikiko
    Lee, Min Sun
    Lee, Jae Sung
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [2] A depth-of-interaction PET detector using a stair-shaped reflector arrangement and a single-ended scintillation light readout
    Son, Jeong-Whan
    Lee, Min Sun
    Lee, Jae Sung
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (02): : 465 - 483
  • [3] An investigation on continuous depth-of-interaction detection using a monolithic scintillator with single-ended readout
    Zhang, H.
    Zhou, R.
    Yang, C.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [4] Single-Ended Readout Depth-of-Interaction Measurements Based on Random Forest Algorithm
    Cheng, Ran
    Wang, Fei
    Li, Shuo
    Li, Xinyu
    Liu, Yu
    Xie, Qingguo
    Xiao, Peng
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2023, 7 (02) : 105 - 112
  • [5] Continuous depth-of-interaction measurement in a single-layer pixelated crystal array using a single-ended readout
    Ito, Mikiko
    Lee, Min Sun
    Lee, Jae Sung
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (05): : 1269 - 1282
  • [6] Design and simulation of a novel method for determining depth-of-interaction in a PET scintillation crystal array using a single-ended readout by a multi-anode PMT
    Ito, Mikiko
    Lee, Jae Sung
    Park, Min-Jae
    Sim, Kwang-Souk
    Hong, Seong Jong
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (13): : 3827 - 3841
  • [7] Prototype pre-clinical PET scanner with depth-of-interaction measurements using single-layer crystal array and single-ended readout
    Lee, Min Sun
    Kim, Kyeong Yun
    Ko, Guen Bae
    Lee, Jae Sung
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (10): : 3983 - 3996
  • [8] Depth-of-interaction measurement in a single-layer crystal array with a single-ended readout using digital silicon photomultiplier
    Lee, Min Sun
    Lee, Jae Sung
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (16): : 6495 - 6514
  • [9] Development of a novel depth-of-interaction encoding method and use of light spreading in a scintillation crystal array with single-ended readout
    Lee, Seung-Jae
    Lee, Chaeyeong
    Chung, Yong Hyun
    Kang, Jihoon
    Baek, Cheol-Ha
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2016, 69 (12) : 1842 - 1846
  • [10] Performance of a depth encoding PET detector module using light sharing and single-ended readout with SiPMs
    Kuang, Zhonghua
    Yang, Qian
    Wang, Xiaohui
    Fu, Xin
    Ren, Ning
    Wu, San
    Zhang, Chunhui
    Zhao, Binqing
    Sang, Ziru
    Hu, Zhanli
    Du, Junwei
    Liang, Dong
    Liu, Xin
    Zheng, Hairong
    Yang, Yongfeng
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (08):