Neon isotopic measurements using high-resolution, multicollector noble gas mass spectrometer: HELIX-MC

被引:11
作者
Marrocchi, Y. [1 ]
Burnard, P. G. [1 ]
Hamilton, D. [2 ]
Colin, A. [1 ]
Pujol, M. [1 ]
Zimmermann, L. [1 ]
Marty, B. [1 ,3 ]
机构
[1] CNRS, Ctr Rech Petrog & Geochim, UPR2300, F-54501 Vandoeuvre Les Nancy, France
[2] Thermo Electron Bremen, D-28197 Bremen, Germany
[3] Ecole Natl Super Geol, F-54501 Vandoeuvre Les Nancy, France
关键词
neon; noble gases; isotopes; mass spectrometry; mass discrimination; MANTLE; CONSTRAINTS;
D O I
10.1029/2008GC002339
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
We describe a new high-resolution, multicollection, noble gas mass spectrometer, the HELIX-MC, developed by GV instruments. The instrument uses a collector housing that holds five "MiniDual'' detection systems, each detector containing two devices: a Faraday cup collector and channel electron multiplier. Each detector is 5.2 mm wide, which permits collecting adjacent beams separated by 1 atomic mass unit (amu) at mass 136. The HELIX-MC operates at high mass resolution (m/Delta m > 1500), which allows the interference of Ar-40(++) on Ne-20(+) to be resolved. We report the results of some tests on the "MiniDual'' collectors, in which we have achieved precise Ne abundance and isotopic measurements. After a correction for doubly ionized CO2 (0.37-1.5%), our results show that the HELIX-MC produces only very limited instrumental Ne isotopic mass fractionation (approximate to -0.5%. amu(-1)). The sensitivity of the HELIX-MC for neon measurement performed on 10 12 ohms collector is around 1.4 x 10(-3) A torr(-1) for quantities of Ne-20 analyzed comprised between 1.27 x 10(-15) and 4.71 x 10(-15) moles. Within this range, the reproducibility of the isotopic measurements of standard gas falls in the range between 0.5 and 0.8% (1 sigma) for Ne-20/Ne-22 and 1 and 1.5% for Ne-21/Ne-22 over a period of several days. The machine characteristics for measuring He are also reported.
引用
收藏
页数:8
相关论文
共 18 条
[1]   Redetermination of the 21Ne relative abundance of the atmosphere, using a high resolution, multi-collector noble gas mass spectrometer (HELIX-MC Plus) [J].
Honda, Masahiko ;
Zhang, Xiaodong ;
Phillips, David ;
Hamilton, Doug ;
Deerberg, Michael ;
Schwieters, Johannes B. .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2015, 387 :1-7
[2]   Performance of the NGX High-Resolution Multiple Collector Noble Gas Mass Spectrometer [J].
Li, Yan ;
Tootell, Damian ;
Holland, Greg ;
Zhou, Zheng .
GEOCHEMISTRY GEOPHYSICS GEOSYSTEMS, 2021, 22 (11)
[3]   Minimisation of pressure dependent mass discrimination in the ion source of the Helix MC Plus noble gas mass spectrometer [J].
Zhang, Xiaodong ;
Honda, Masahiko .
CHEMICAL GEOLOGY, 2017, 473 :50-54
[4]   Iron Isotopic Measurement using Large-Geometry High-Resolution Multi-Collector Inductively Coupled Plasma Mass Spectrometer [J].
Lei, Yvtian ;
Li, Ming ;
Wang, Zaicong ;
Zhu, Yangtao ;
Hu, Zhaochu ;
Li, Yongsheng ;
Chai, Xinna .
ATOMIC SPECTROSCOPY, 2022, 43 (03) :214-222
[5]   High precision nitrogen isotope measurements in oceanic basalts using a static triple collection noble gas mass spectrometer [J].
Barry, P. H. ;
Hilton, D. R. ;
Halldorsson, S. A. ;
Hahm, D. ;
Marti, K. .
GEOCHEMISTRY GEOPHYSICS GEOSYSTEMS, 2012, 13
[6]   Cluster Measurements at CLOUD using a High Resolution Ion Mobility Spectrometer - Mass Spectrometer Combination [J].
Adamov, Alexey ;
Junninen, Heikki ;
Duplissy, Jonathan ;
Sipila, Mikko ;
Kulmala, Markku .
NUCLEATION AND ATMOSPHERIC AEROSOLS, 2013, 1527 :350-353
[7]   High-precision iron isotopic measurements in low resolution using collision cell (CC)-MC-ICP-MS [J].
Wang, Jing ;
Tang, Dong-Mei ;
Su, Ben-Xun ;
Yuan, Qing-Han ;
Li, Wen-Jun ;
Gao, Bing-Yu ;
Chen, Kai-Yun ;
Bao, Zhi-An ;
Zhao, Ye .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (09) :1869-1875
[8]   Automatic 40Ar/39Ar Dating Techniques Using Multicollector ARGUS VI Noble Gas Mass Spectrometer with Self-Made Peripheral Apparatus [J].
Bai, Xiu-Juan ;
Qiu, Hua-Ning ;
Liu, Wen-Gui ;
Mei, Lian-Fu .
JOURNAL OF EARTH SCIENCE, 2018, 29 (02) :408-415
[9]   Gas-Phase Fragmentation Studies of Biotinylated, Hexaethylene Glycol–Spacered Oligosaccharides—Molecular Probes—Using Electrospray Mass Spectrometry on a Hybrid High-Resolution Mass Spectrometer [J].
A. O. Chizhov ;
D. A. Argunov ;
M. L. Gening ;
E. V. Sukhova ;
E. A. Khatuntseva ;
A. A. Karelin ;
B. S. Komarova ;
M. V. Orekhova ;
V. B. Krylov ;
D. V. Yasunskii ;
Yu. E. Tsvetkov ;
N. E. Nifantiev .
Journal of Analytical Chemistry, 2017, 72 :1312-1321
[10]   Evidencing 98 secondary metabolites of Penicillium verrucosum using substrate isotopic labeling and high-resolution mass spectrometry [J].
Hautbergue, Thais ;
Puel, Olivier ;
Tadrist, Souria ;
Meneghetti, Lauriane ;
Pean, Michel ;
Delaforge, Marcel ;
Debrauwer, Laurent ;
Oswald, Isabelle P. ;
Jamin, Emilien L. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1071 :29-43