Combined optic system based on polycapillary X-ray optics and single-bounce monocapillary optics for focusing X-rays from a conventional laboratory X-ray source

被引:6
作者
Sun, Xuepeng [1 ,2 ,3 ]
Liu, Zhiguo [1 ,2 ,3 ]
Sun, Tianxi [1 ,2 ,3 ]
Yi, Longtao [1 ,2 ,3 ]
Sun, Weiyuan [1 ,2 ,3 ]
Li, Fangzuo [1 ,2 ,3 ]
Jiang, Bowen [1 ,2 ,3 ]
Ma, Yongzhong [4 ]
Ding, Xunliang [1 ,2 ,3 ]
机构
[1] Beijing Normal Univ, Key Lab Beam Technol & Mat Modificat, Minist Educ, Beijing 100875, Peoples R China
[2] Beijing Normal Univ, Coll Nucl Sci & Technol, Beijing 100875, Peoples R China
[3] Beijing Radiat Ctr, Beijing 100875, Peoples R China
[4] Ctr Dis Control & Prevent Beijing, Beijing 100013, Peoples R China
基金
中国国家自然科学基金;
关键词
Combined optic system; Polycapillary X-ray optics; Single bounce monocapillary optics; X-ray focusing; CAPILLARY;
D O I
10.1016/j.nima.2015.08.043
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Two combined optic systems based on polycapillary X-ray optics and single-bounce monocapillary optics (SBMO) were designed for focusing the X-rays from a conventional laboratory X-ray source. One was based on a polycapillary focusing X-ray lens (PFXRL) and a single-bounce ellipsoidal capillary (SBEC), in which the output focal spot with the size of tens of micrometers of the PFXRL was used as the "virtual" X-ray source for the SBEC. The other system was based on a polycapillary parallel X-ray lens (PPXRL) and a single-bounce parabolic capillary (SBPC), in which the PPXRL transformed the divergent X-ray beam from an X-ray source into a quasi-parallel X-ray beam with the divergence of sever milliradians as the incident illumination of the SBPC. The experiment results showed that the combined optic systems based on PFXRL and SBEC with a Mo rotating anode X-ray generator with the focal spot with a diameter of 300 mu m could obtain a focal spot with the total gain of 14,300 and focal spot size of 37.4 mu m, and the combined optic systems based on [PXRL and SBPC with the same X-ray source mentioned above could acquire a focal spot with the total gain of 580 and focal spot size of 58.3 mu m, respectively. The two combined optic systems have potential applications in micro X-ray diffraction, micro X-ray fluorescence, micro X-ray absorption near edge structure, full field X-ray microscopes and so on. (C) 2015 Elsevier B.V. All rights reserved,
引用
收藏
页码:5 / 9
页数:5
相关论文
共 21 条
[1]   High-flux hard X-ray microbeam using a single-bounce capillary with doubly focused undulator beam [J].
Barrea, Raul A. ;
Huang, Rong ;
Cornaby, Sterling ;
Bilderback, Donald H. ;
Irving, Thomas C. .
JOURNAL OF SYNCHROTRON RADIATION, 2009, 16 :76-82
[2]   Fundamental characteristics of hybrid X-ray focusing optics for micro X-ray fluorescence analysis [J].
Komatani, Shintaro ;
Nakamachi, Kazuo ;
Nakano, Kazuhiko ;
Ohzawa, Sumito ;
Uchihara, Hiroshi ;
Bando, Atsushi ;
Tsuji, Kouichi .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 309 :260-263
[3]   Focusing capillary optics for use in solution small-angle X-ray scattering [J].
Lamb, Jessica S. ;
Cornaby, Sterling ;
Andresen, Kurt ;
Kwok, Lisa ;
Park, Hye Yoon ;
Qiu, Xiangyun ;
Smilgies, Detlef-M. ;
Bilderback, Donald H. ;
Pollack, Lois .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2007, 40 :193-195
[4]   Confocal three-dimensional micro X-ray scatter imaging for non-destructive detecting foreign bodies with low density and low-Z materials in food products [J].
Li, Fangzuo ;
Liu, Zhiguo ;
Sun, Tianxi ;
Ma, Yongzhong ;
Ding, Xunliang .
FOOD CONTROL, 2015, 54 :120-125
[5]   Fish otolith trace element maps: new approaches with synchrotron microbeam x-ray fluorescence [J].
Limburg, Karin E. ;
Huang, Rong ;
Bilderback, Donald H. .
X-RAY SPECTROMETRY, 2007, 36 (05) :336-342
[6]   Performances for confocal X-ray diffraction technology based on polycapillary slightly focusing X-ray optics [J].
Liu, Hehe ;
Liu, Zhiguo ;
Sun, Tianxi ;
Peng, Song ;
Ma, Yongzhong ;
Sun, Weiyuan ;
Li, Yude ;
Lin, Xiaoyan ;
Zhao, Weigang ;
Zhao, Guangcui ;
Luo, Ping ;
Pan, Qiuli ;
Ding, Xunliang .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 723 :1-4
[7]   A laboratory based system for Laue micro x-ray diffraction [J].
Lynch, P. A. ;
Stevenson, A. W. ;
Liang, D. ;
Parry, D. ;
Wilkins, S. ;
Tamura, N. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (02)
[8]   Spatially Resolved In Situ Measurements of the Ion Distribution Near the Surface of Electrode in a Steady-State Diffusion in an Electrolytic Tank with Confocal Micro X-ray Fluorescence [J].
Peng, Song ;
Liu, Zhiguo ;
Sun, Tianxi ;
Ma, Yongzhong ;
Ding, Xunliang .
ANALYTICAL CHEMISTRY, 2014, 86 (01) :362-366
[9]   Microbeam high angular resolution x-ray diffraction in InGaN/GaN selective-area-grown ridge structures [J].
Sirenko, A. A. ;
Kazimirov, A. ;
Cornaby, S. ;
Bilderback, D. H. ;
Neubert, B. ;
Brueckner, P. ;
Scholz, F. ;
Shneidman, V. ;
Ougazzaden, A. .
APPLIED PHYSICS LETTERS, 2006, 89 (18)
[10]   Two-step hard X-ray focusing combining Fresnel zone plate and single-bounce ellipsoidal capillary [J].
Snigirev, A. ;
Bjeoumikhov, A. ;
Erko, A. ;
Snigireva, I. ;
Grigoriev, M. ;
Yunkin, V. ;
Erko, M. ;
Bjeoumikhova, S. .
JOURNAL OF SYNCHROTRON RADIATION, 2007, 14 :326-330