Volumetric absorptive microsampling and dried blood spot microsampling vs. conventional venous sampling for tacrolimus trough concentration monitoring

被引:51
|
作者
Veenhof, Herman [1 ]
Koster, Remco A. [1 ,3 ]
Junier, Lenneke A. T. [1 ]
Berger, Stefan P. [4 ]
Bakker, Stephan J. L. [4 ]
Touw, Daan J. [1 ,2 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Clin Pharm & Pharmacol, Groningen, Netherlands
[2] Univ Groningen, Groningen Res Inst Pharm, Dept Pharmaceut Anal, Groningen, Netherlands
[3] Bioanalyt Lab, PRA Hlth Sci, Assen, Netherlands
[4] Univ Groningen, Univ Med Ctr Groningen, Dept Internal Med, Div Nephrol, Groningen, Netherlands
关键词
dried blood spots; immunosuppressants; microsampling; therapeutic drug monitoring; volumetric absorptive microsampling; LC-MS/MS; CYCLOSPORINE-A; CLINICAL VALIDATION; TRANSPLANT PATIENTS; HEMATOCRIT; EVEROLIMUS; SIROLIMUS; IMMUNOSUPPRESSANTS; COLLECTION; CREATININE;
D O I
10.1515/cclm-2019-1260
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: Monitoring tacrolimus blood concentrations is important for preventing allograft rejection in transplant patients. Our hospital offers dried blood spot (DRS) sampling, giving patients the opportunity to sample a drop of blood from a fingerprick at home, which can be sent to the laboratory by mail. In this study, both a volumetric absorptive microsampling (VAMS) device and DBS sampling were compared to venous whole blood (WB) sampling. Methods: A total of 130 matched fingerprick VAMS, fingerprick DBS and venous WB samples were obtained from 107 different kidney transplant patients by trained phlebotomists for method comparison using Passing-Bablok regression. Bias was assessed using Bland-Altman. A multidisciplinary team pre-defined an acceptance limit requiring >80% of all matched samples within 15% of the mean of both samples. Sampling quality was evaluated for both VAMS and DBS samples. Results: 32.3% of the VAMS samples and 6.2% of the DBS samples were of insufficient quality, leading to 88 matched samples fit for analysis. Passing-Bablok regression showed a significant difference between VAMS and WB, with a slope of 0.88 (95% CI 0.81-0.97) but not for DBS (slope 1.00; 95% CI 0.95-1.04). Both VAMS (after correction for the slope) and DBS showed no significant bias in Bland-Altman analysis. For VAMS and DBS, the acceptance limit was met for 83.0% and 96.6% of the samples, respectively. Conclusions: VAMS sampling can replace WB sampling for tacrolimus trough concentration monitoring, but VAMS sampling is currently inferior to DBS sampling, both regarding sample quality and agreement with WB tacrolimus concentrations.
引用
收藏
页码:1687 / 1695
页数:9
相关论文
共 45 条
  • [41] Development, validation, and application of a quantitative volumetric absorptive microsampling–based method in finger prick blood by means of LC-HRMS/MS applicable for adherence monitoring of antipsychotics
    Cathy M. Jacobs
    Lea Wagmann
    Markus R. Meyer
    Analytical and Bioanalytical Chemistry, 2021, 413 : 1729 - 1737
  • [42] Closing the gap - development of an analytical methodology using volumetric absorptive microsampling of finger prick blood followed by LC-HRMS/MS for adherence monitoring of antihypertensive drugs
    Jacobs, Cathy M.
    Kunz, Michael
    Mahfoud, Felix
    Wagmann, Lea
    Meyer, Markus R.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 415 (01) : 167 - 177
  • [43] Development, validation, and application of a quantitative volumetric absorptive microsampling-based method in finger prick blood by means of LC-HRMS/MS applicable for adherence monitoring of antipsychotics
    Jacobs, Cathy M.
    Wagmann, Lea
    Meyer, Markus R.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (06) : 1729 - 1737
  • [44] Therapeutic Drug Monitoring of Tacrolimus Based on Volumetric Absorptive Microsampling Technique (VAMS) in Renal Transplant Pediatric Recipients-LC-MS/MS Method Development, Hematocrit Effect Evaluation, and Clinical Application
    Kocur, Arkadiusz
    Marszalek, Dorota
    Rubik, Jacek
    Czajkowska, Agnieszka
    Pawinski, Tomasz
    PHARMACEUTICS, 2023, 15 (01)
  • [45] Preliminary comparative study of HBA1c measurement by IEX-HPLC Bio-Rad in dried blood spot vs. whole venous blood
    Hadami, Khaoula
    Bennai, Redouane Mammar
    Touyar, Nora
    Amar, Lahcen
    Harisoa, Yasminah Josephine
    Kabbaj, Hakima
    Benouda, Amina
    Belefquih, Bouchra
    ANNALES DE BIOLOGIE CLINIQUE, 2025, 83 (-1) : 61 - 71