Volumetric absorptive microsampling and dried blood spot microsampling vs. conventional venous sampling for tacrolimus trough concentration monitoring
被引:51
|作者:
Veenhof, Herman
[1
]
Koster, Remco A.
[1
,3
]
Junier, Lenneke A. T.
[1
]
Berger, Stefan P.
[4
]
Bakker, Stephan J. L.
[4
]
Touw, Daan J.
[1
,2
]
机构:
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Clin Pharm & Pharmacol, Groningen, Netherlands
[2] Univ Groningen, Groningen Res Inst Pharm, Dept Pharmaceut Anal, Groningen, Netherlands
[3] Bioanalyt Lab, PRA Hlth Sci, Assen, Netherlands
[4] Univ Groningen, Univ Med Ctr Groningen, Dept Internal Med, Div Nephrol, Groningen, Netherlands
关键词:
dried blood spots;
immunosuppressants;
microsampling;
therapeutic drug monitoring;
volumetric absorptive microsampling;
LC-MS/MS;
CYCLOSPORINE-A;
CLINICAL VALIDATION;
TRANSPLANT PATIENTS;
HEMATOCRIT;
EVEROLIMUS;
SIROLIMUS;
IMMUNOSUPPRESSANTS;
COLLECTION;
CREATININE;
D O I:
10.1515/cclm-2019-1260
中图分类号:
R446 [实验室诊断];
R-33 [实验医学、医学实验];
学科分类号:
1001 ;
摘要:
Objectives: Monitoring tacrolimus blood concentrations is important for preventing allograft rejection in transplant patients. Our hospital offers dried blood spot (DRS) sampling, giving patients the opportunity to sample a drop of blood from a fingerprick at home, which can be sent to the laboratory by mail. In this study, both a volumetric absorptive microsampling (VAMS) device and DBS sampling were compared to venous whole blood (WB) sampling. Methods: A total of 130 matched fingerprick VAMS, fingerprick DBS and venous WB samples were obtained from 107 different kidney transplant patients by trained phlebotomists for method comparison using Passing-Bablok regression. Bias was assessed using Bland-Altman. A multidisciplinary team pre-defined an acceptance limit requiring >80% of all matched samples within 15% of the mean of both samples. Sampling quality was evaluated for both VAMS and DBS samples. Results: 32.3% of the VAMS samples and 6.2% of the DBS samples were of insufficient quality, leading to 88 matched samples fit for analysis. Passing-Bablok regression showed a significant difference between VAMS and WB, with a slope of 0.88 (95% CI 0.81-0.97) but not for DBS (slope 1.00; 95% CI 0.95-1.04). Both VAMS (after correction for the slope) and DBS showed no significant bias in Bland-Altman analysis. For VAMS and DBS, the acceptance limit was met for 83.0% and 96.6% of the samples, respectively. Conclusions: VAMS sampling can replace WB sampling for tacrolimus trough concentration monitoring, but VAMS sampling is currently inferior to DBS sampling, both regarding sample quality and agreement with WB tacrolimus concentrations.
引用
收藏
页码:1687 / 1695
页数:9