On an innovative integrated technique for energy refurbishment of historical buildings: Thermal-energy, economic and environmental analysis of a case study

被引:95
|
作者
Pisello, Anna Laura [1 ]
Petrozzi, Alessandro [1 ]
Castaldo, Veronica Lucia [1 ]
Cotana, Franco [1 ]
机构
[1] Univ Perugia, CIRIAF Interuniv Res Ctr, I-06125 Perugia, Italy
关键词
Historic buildings; Dynamic simulation; Energy retrofitting; Passive and active systems; Cool roof; Geothermal heat pump; HEAT-PUMP SYSTEMS; EXISTING BUILDINGS; PERFORMANCE; RETROFIT; SIMULATION; EFFICIENCY; CONSUMPTION;
D O I
10.1016/j.apenergy.2015.05.061
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In the last decades, increasing attention has been paid to the enhancement of energy performance and comfort conditions of historic buildings, where the necessity to preserve architectural heritage does not allow typical invasive retrofit interventions. The need for a replicable methodology for improving the sustainability of historic buildings based on the integration of energy efficiency solutions with renewable technologies is here addressed, by riding over the constraints imposed by architectural preservations, rather taking advantage of heritage architectural peculiarities. The case study is represented by Palazzo Gallenga Stuart, a historical university building located in central Italy. The optimization of the building energy efficiency has been pursued through two strategies specifically prototyped for application in historic buildings, i.e. innovative cool tiles with the same appearance of traditional historic tiles, and a geothermal heat pump system with water storage tanks positioned in the under-ground unoccupied areas of the building previously used as archives, also preventing the use of external units spoiling the building facade. Four retrofit scenarios were analyzed and compared from a both technical and economical point of view. The results showed that the application of the innovative cool tiles lead to a maximum cooling energy saving of 14.0% and 3.8% in the classrooms of the top floor and in the whole building, respectively. Furthermore, the installation of a more effective energy plant leads to an average energy saving of 64.3% and 67.0% in terms of heating and cooling demand, respectively. The combination of the two effects leads to an average energy saving of 64.0% for heating and 69.2% for cooling. Additionally, the cost-benefit analysis showed a payback time of 5 years. This work shows the important environmental benefit achievable by researching around smart and innovative integrated systems for energy saving in historic buildings having a great potential in reducing energy demand and carbon emissions, in ancient European countries in particular. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1313 / 1322
页数:10
相关论文
共 50 条
  • [41] The European Standards for Energy Efficiency in Buildings: an analysis of the Evolution with Reference to a Case Study
    Cirrincione, Laura
    Marvuglia, Antonino
    Peri, Giorgia
    Rizzo, Gianfranco
    Scaccianoce, Gianluca
    74TH ATI NATIONAL CONGRESS: ENERGY CONVERSION: RESEARCH, INNOVATION AND DEVELOPMENT FOR INDUSTRY AND TERRITORIES, 2019, 2191
  • [42] Improvement of the Sustainability of Existing School Buildings According to the Leadership in Energy and Environmental Design (LEED)® Protocol: A Case Study in Italy
    Dall'O', Giuliano
    Bruni, Elisa
    Panza, Angela
    ENERGIES, 2013, 6 (12): : 6487 - 6507
  • [43] An energy, environmental, management and economic analysis of energy efficient system towards renewable energy community: The case study of multi-purpose energy community
    Ceglia, F.
    Esposito, P.
    Faraudello, A.
    Marrasso, E.
    Rossi, P.
    Sasso, M.
    JOURNAL OF CLEANER PRODUCTION, 2022, 369
  • [44] Integrated Assessment-Optimization Approach for Building Refurbishment Projects: Case Study of Passive Energy Measures
    Fard, Farhad Amiri
    Nasiri, Fuzhan
    JOURNAL OF COMPUTING IN CIVIL ENGINEERING, 2018, 32 (05)
  • [45] Dynamic energy performance analysis: Case study for energy efficiency retrofits of hospital buildings
    Buonomano, Annamaria
    Calise, Francesco
    Ferruzzi, Gabriele
    Palombo, Adolfo
    ENERGY, 2014, 78 : 555 - 572
  • [46] Thermal-energy analysis of natural "cool'' stone aggregates as passive cooling and global warming mitigation technique
    Castaldo, V. L.
    Coccia, V
    Cotana, F.
    Pignatta, G.
    Pisello, A. L.
    Rossi, F.
    URBAN CLIMATE, 2015, 14 : 301 - 314
  • [47] Energy assessment, economic analysis, and environmental study of an Iranian building: The effect of wall materials and climatic conditions
    Sadati, Seyed Esmaeil
    Rahbar, Nader
    Kargarsharifabad, Hadi
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2023, 56
  • [48] Dynamic 4E (energy, exergy, economic and environmental) analysis and tri-criteria optimization of a building-integrated plant with latent heat thermal energy storage
    Gholamian, E.
    Zare, V.
    Javani, N.
    Ranjbar, F.
    ENERGY CONVERSION AND MANAGEMENT, 2022, 267
  • [49] Predicting climate change and occupants' behaviour impact on thermal-energy performance of global south housing: Case study in Brazil
    Cruz, Alexandre Santana
    Goncalves Bastos, Leopoldo Eurico
    INDOOR AND BUILT ENVIRONMENT, 2024, 33 (05) : 808 - 827
  • [50] Development of an Integrated Solar-Biomass Energy System for Near-Zero Energy Buildings: A Technical and Environmental Study
    Karkon, Ehsan
    Liravi, Mohammad
    Georges, Laurent
    Li, Jinping
    Novakovic, Vojislav
    BUILDSIM NORDIC 2024, 2024, 562