Long-term outcomes after Lichtenstein repair using titanium-coated mesh: A retrospective cohort study

被引:2
作者
Akalin, Cagri [1 ,2 ]
机构
[1] Ordu Med Sch, Dept Gen Surg, Ordu, Turkey
[2] Ordu Univ & Res Hosp, TR-52200 Ordu, Turkey
关键词
Lichtenstein repair; Titanium-coated mesh; Polypropylene mesh; Recurrence; Foreign body feeling; Chronic pain; RANDOMIZED CLINICAL-TRIAL; INGUINAL-HERNIA REPAIR; POLYPROPYLENE MESH; LIGHTWEIGHT MESH; CHRONIC PAIN; PORE-SIZE; MULTICENTER; WEIGHT; IMPACT;
D O I
10.12669/pjms.37.1.2694
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To examine the long-term outcomes such as recurrence, foreign body feeling and chronic pain of titanium-coated mesh (TCM) versus standard polypropylene mesh (PM) after Lichtenstein repair (LR). Methods: In this retrospective cohort study, patients who underwent TCM and PM in LR were evaluated between May 2014 and January 2018 at Ordu University Training and Research Hospital in Turkey. Primary outcomes (age, gender, body mass index, smoking habits, comorbid diseases, American Society of Anesthesiologists score, hernia type, side of hernia, duration of hernia presentation and operative time) and secondary outcomes (surgical site occurence, recurrence, foreign body feeling and chronic pain) were analyzed. Patients were divided into two groups according to the mesh elected (TCM and PM); titanium group (TG) and polypropylene group (PG), respectively. Results: In this study, 221 patients were analyzed; TCM was used in 72 (32.6%) patients and PM was used in 149 (67.4%) patients. No difference was found between groups in terms of primary outcomes (p>0.05). In the analysis of secondary outcomes, surgical site occurence was similar in both groups (p>0.05). Recurrence was observed in 1.39% (n=1) of TG and 2.01% (n=3) of PG. No difference was found between groups in terms of recurrence (p=0.606). Foreign body feeling was observed in 15.3% (n=11) of TG and 27.5% (n=41) of PG. Chronic pain was observed in 4.2% (n=3) of TG and 12.8% (n=9) of PG. Significant differences were found between groups in terms of chronic pain and foreign body feeling (p=0.046 and p=0.044, respectively). Conclusion: The result of this study shows that in LR, TCM leads to less foreign body feeling and chronic pain than PM. However, there was no difference in terms of recurrence between these meshes.
引用
收藏
页码:81 / 86
页数:6
相关论文
共 24 条
[1]   Lichtenstein tension-free hernioplasty: Its inception, evolution, and principles [J].
Amid P.K. .
Hernia, 2004, 8 (1) :1-7
[2]   Past, Present and Future of Surgical Meshes: A Review [J].
Baylon, Karen ;
Rodriguez-Camarillo, Perla ;
Elias-Zuniga, Alex ;
Antonio Diaz-Elizondo, Jose ;
Gilkerson, Robert ;
Lozano, Karen .
MEMBRANES, 2017, 7 (03)
[3]   Monocyte-biomaterial interaction inducing phenotypic dynamics of monocytes: a possible role of monocyte subsets in biocompatibility [J].
Bhardwaj, RS ;
Henze, U ;
Klein, B ;
ZwadloKlarwasser, G ;
Klinge, U ;
Mittermayer, C ;
Klosterhalfen, B .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1997, 8 (12) :737-742
[4]   Pain and quality of life after inguinal hernia surgery: a multicenter randomized controlled trial comparing lightweight vs heavyweight mesh (Supermesh Study) [J].
Bona, Stefano ;
Rosati, Riccardo ;
Opocher, Enrico ;
Fiore, Barbara ;
Montorsi, Marco .
UPDATES IN SURGERY, 2018, 70 (01) :77-83
[5]   Standard polypropylene mesh vs lightweight mesh for Lichtenstein repair of primary inguinal hernia: A randomized controlled trial [J].
Demetrashvili, Zaza ;
Khutsishvili, Kakhi ;
Pipia, Irakli ;
Kenchadze, Giorgi ;
Ekaladze, Eka .
INTERNATIONAL JOURNAL OF SURGERY, 2014, 12 (12) :1380-1384
[6]   Prosthetic material in inguinal hernia repair: How do I choose? [J].
Earle, David B. ;
Mark, Lisa A. .
SURGICAL CLINICS OF NORTH AMERICA, 2008, 88 (01) :179-+
[7]  
Forte A, 2002, G Chir, V23, P88
[8]   Impact of polymer pore size on the interface scar formation in a rat model [J].
Klinge, U ;
Klosterhalfen, B ;
Birkenhauer, V ;
Junge, K ;
Conze, J ;
Schumpelick, V .
JOURNAL OF SURGICAL RESEARCH, 2002, 103 (02) :208-214
[9]   Randomized clinical trial of groin hernia repair with titanium-coated lightweight mesh compared with standard polypropylene mesh [J].
Koch, A. ;
Bringman, S. ;
Myrelid, P. ;
Smeds, S. ;
Kald, A. .
BRITISH JOURNAL OF SURGERY, 2008, 95 (10) :1226-1231
[10]   Comparison of partially-absorbable lightweight mesh with heavyweight mesh for inguinal hernia repair: multicenter randomized study [J].
Lee, Seong Dae ;
Son, Taeil ;
Lee, Jae-Bum ;
Chang, Yeon Soo .
ANNALS OF SURGICAL TREATMENT AND RESEARCH, 2017, 93 (06) :322-330