Two-part implant abutments with titanium and ceramic components: Surface modification affects retention forces-An in-vitro study

被引:20
|
作者
von Maltzahn, Nadine Freifrau [1 ]
Bernard, Sebastian
Kohorst, Philipp [1 ]
机构
[1] Hannover Med Sch, Dept Prosthet Dent & Biomed Mat Sci, Carl Neuberg Str 1, D-30625 Hannover, Germany
关键词
bonding; glass ceramic; modification of surface; thermal aging; titanium; zirconia; SHEAR BOND STRENGTH; FRACTURE-RESISTANCE; ZIRCONIUM; CEMENT; RESIN;
D O I
10.1111/clr.13495
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives Two-part abutments consist of titanium base and ceramic coping. Their long-term success is largely determined by the mechanical stability. The aim of the present study was to investigate the retention forces of two-part implant abutments. The study included zirconia and lithium disilicate ceramics copings, with different surface treatments and resin-based luting agents. Material and Methods The analysis of retention forces was based on a total of 70 test specimens. Seven surface modifications and three resin-based luting agents were employed for the bonding of components in the seven groups (n = 70). All surfaces of titanium bases-except for a control-were pretreated with aluminum oxide blasting, either alone or in combination with surface activating primers. Surfaces of ceramic copings were also treated mechanically by sandblasting, either alone or with acid etching or different primers. All specimens underwent thermal aging (10(4) cycles, 5 degrees C/55 degrees C). The retention forces between the two parts were measured with a pull-off test. The results were analyzed by two-way ANOVA statistics. Fracture patterns were evaluated by light and scanning electron microscopy. Results No mechanical pretreatment of the titanium (group 2) base resulted in the lowest retention. The combination with Monobond plus leads to the highest pull-off forces for both ceramic materials. Conclusions Surface modifications and resin-based agents influence the retention of components of two-part abutments. Lithium disilicate ceramic copings reached comparable results of retention to the typically used zirconia copings.
引用
收藏
页码:903 / 909
页数:7
相关论文
共 14 条
  • [1] Retention Forces between Titanium and Zirconia Components of Two-Part Implant Abutments with Different Techniques of Surface Modification
    von Maltzahn, Nadine Freifrau
    Holstermann, Jan
    Kohorst, Philipp
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (04) : 735 - 744
  • [2] In vitro evaluation of the influence of titanium nitride coating on the retention force between components of two-part abutments
    von Maltzahn, Nadine Freifrau
    Holstermann, Jan
    Stiesch, Meike
    Kohorst, Philipp
    BMC ORAL HEALTH, 2021, 21 (01)
  • [3] In vitro evaluation of the influence of titanium nitride coating on the retention force between components of two-part abutments
    Nadine Freifrau von Maltzahn
    Jan Holstermann
    Meike Stiesch
    Philipp Kohorst
    BMC Oral Health, 21
  • [4] Influence of sterilization on the retention forces of lithium disilicate and polymer-infiltrated ceramic-network crowns bonded to titanium base abutments: An in-vitro study
    Lafori, Andreina
    Sailer, Irena
    Fehmer, Vincent
    Mojon, Philippe
    Burkhardt, Felix
    Pitta, Joao
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (04) : 377 - 385
  • [5] Retention of CAD/CAM All-Ceramic Crowns on Prefabricated Implant Abutments: An In Vitro Comparative Study of Luting Agents and Abutment Surface Area
    Carnaggio, Thomas V.
    Conrad, Robert
    Engelmeier, Robert L.
    Gerngross, Peter
    Paravina, Rade
    Perezous, Leticia
    Powers, John M.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2012, 21 (07): : 523 - 528
  • [6] Biocompatibility, Surface Morphology, and Bacterial Load of Dental Implant Abutments following Decontamination Protocols: An In-Vitro Study
    Sharon, Esi
    Pietrokovski, Yoav
    Engel, Ilana
    Assali, Rula
    Houri-Haddad, Yael
    Beyth, Nurit
    MATERIALS, 2023, 16 (11)
  • [7] Retention of implant retained obturator using two implant placement configurations for maxillectomy cases: in-vitro study
    Aboseada, Nourhan I.
    Mohamed, Faten S.
    El-shabrawy, Sonia M.
    BMC ORAL HEALTH, 2024, 24 (01):
  • [8] Retention Forces of Implant-Supported Single Crowns and Fixed Dental Prostheses after Cementation: An In-Vitro Study
    Bishti, Shaza
    Siouri, Jousef
    Wolfart, Stefan
    Tuna, Taskin
    ORAL, 2022, 2 (01): : 29 - 40
  • [9] Temporary Implant-Supported Single Crowns Using Titanium Base Abutments: An In Vitro Study on Bonding Stability and Pull-out Forces
    Pitta, Joao
    Bijelic-Donova, Jasmina
    Burkhardt, Felix
    Fehmer, Vincent
    Narhi, Timo
    Sailer, Irena
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2020, 33 (05) : 546 - 552
  • [10] Retentive Strength of CAD/CAM-Fabricated All-Ceramic Crowns Luted on Titanium Implant Abutments Using Different Ceramic Materials and Luting Agents: An In Vitro Study
    Bjelopavlovic, Monika
    Weyhrauch, Michael
    Scheller, Herbert
    Wentaschek, Stefan
    Lehmann, Karl Martin
    MATERIALS, 2022, 15 (19)