Label-free nanostructured biosensor for Schistosoma mansoni detection in complex biological fluids

被引:16
|
作者
Santos, Giselle S. [1 ,2 ]
Caldas, Raquel G. S. C. [2 ]
Melo, Fabio L. [3 ]
Bruscky, Igor S. [4 ]
Silva, Maria A. L. [3 ]
Wanderley, Leandro B. [5 ]
Andrade, Cesar A. S. [2 ]
Oliveira, Maria D. L. [1 ,2 ]
机构
[1] Univ Fed Pernambuco, Programa Posgrad Bioquim & Fisiol, BR-50670901 Recife, PE, Brazil
[2] Univ Fed Pernambuco, Dept Bioquim, BR-50670901 Recife, PE, Brazil
[3] Inst Aggeu Magalhaes FIOCRUZ, Dept Parasitol, BR-50670420 Recife, PE, Brazil
[4] UNINASSAU, Fac Med, BR-51021140 Recife, PE, Brazil
[5] Ctr Univ Brasileiro UNIBRA, BR-50050230 Recife, PE, Brazil
关键词
Schistosoma mansoni; Genosensor; Nanoparticles; Electrodeposition; Electrochemical impedance spectroscopy; Cyclic voltammetry; KATO-KATZ TECHNIQUE; GOLD NANOPARTICLES; CEREBROSPINAL-FLUID; SELECTIVE DETERMINATION; JAPONICUM; DIAGNOSIS; IMMUNOSENSOR; GENOSENSOR; QUERCETIN; OXIDE;
D O I
10.1016/j.talanta.2019.05.111
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Schistosomiasis is a neglected tropical disease with a worldwide prevalence. Neuroschistosomiasis is the most severe presentation of the disease and affects the central nervous system. In this work, Schistosoma mansoni detection was based on self-assembled layers of 3-mercaptopropyltrimethoxysilane (MPTS) and electrosynthesized gold nanoparticles (AuNPs). The DNA probe was chemisorbed onto AuNPs. The biosensor was characterized by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The impedimetric response of the MPTS-AuNPs-DNA(Probe) system indicates an effective modification of the electrode surface. Topographical atomic force microscopy images were used to characterize the self-assembled layers on the gold electrode surface. The proposed biosystem was able to recognize the S. mansoni genome sequence at different concentrations in samples of urine, cerebrospinal fluid, and serum. Several concentration ranges were evaluated: urine (27-50 pg mu L-1), cerebrospinal fluid (25-60 pg mu L-1) serum (27-42 pg mu L-1). The limit detection (LOD) of the biosensor was 0.6 pg mu L-1. The developed label-free genosensor was able to detect small concentrations of S. mansoni DNA in complex biological fluids.
引用
收藏
页码:395 / 401
页数:7
相关论文
共 50 条
  • [31] Label-free detection of γ-aminobutyric acid based on silicon nanowire biosensor
    Jin-Ho Lee
    Eun-Ji Chae
    Soo-jeong Park
    Jeong-Woo Choi
    Nano Convergence, 6
  • [32] Label-free detection of exosomes using a surface plasmon resonance biosensor
    Abu Ali Ibn Sina
    Ramanathan Vaidyanathan
    Alain Wuethrich
    Laura G. Carrascosa
    Matt Trau
    Analytical and Bioanalytical Chemistry, 2019, 411 : 1311 - 1318
  • [33] Label-free slot-waveguide biosensor for the detection of DNA hybridization
    Dar, Tuffail
    Homola, Jiri
    Rahman, B. M. Azizur
    Rajarajan, Muttukrishnan
    APPLIED OPTICS, 2012, 51 (34) : 8195 - 8202
  • [34] Label-free quantitative detection using porous silicon as optical biosensor
    钟福如
    马晓林
    吕小毅
    贾振红
    OptoelectronicsLetters, 2012, 8 (04) : 314 - 317
  • [35] Label-free detection of cardiac troponin I with a photonic crystal biosensor
    Zhang, Bailin
    Morales, Andres W.
    Peterson, Ralph
    Tang, Liang
    Ye, Jing Yong
    BIOSENSORS & BIOELECTRONICS, 2014, 58 : 107 - 113
  • [36] Electrochemical aptamer biosensor for DNA detection based on label-free aptamers
    Li, Li
    Chen, Zhengbo
    BIOELECTROCHEMISTRY, 2023, 153
  • [37] Label-free detection of γ-aminobutyric acid based on silicon nanowire biosensor
    Lee, Jin-Ho
    Chae, Eun-Ji
    Park, Soo-Jeong
    Choi, Jeong-Woo
    NANO CONVERGENCE, 2019, 6 (1)
  • [38] LABEL-FREE ELECTROCHEMICAL DETECTION OF TETRACYCLINE BY AN APTAMER NANO-BIOSENSOR
    Zhang, Juankun
    Wu, Yan
    Zhang, Binbin
    Li, Min
    Jia, Shiru
    Jiang, Shuhai
    Zhou, Hao
    Zhang, Yi
    Zhang, Chaozheng
    Turner, Anthony P. F.
    ANALYTICAL LETTERS, 2012, 45 (09) : 986 - 992
  • [39] Aptamer-Based Label-Free Impedimetric Biosensor for Detection of Progesterone
    Jimenez, Gaston Contreras
    Eissa, Shimaa
    Ng, Andy
    Alhadrami, Hani
    Zourob, Mohammed
    Siaj, Mohamed
    ANALYTICAL CHEMISTRY, 2015, 87 (02) : 1075 - 1082
  • [40] Label-free optical biosensor for direct complex DNA detection using Vitis vinifera L.
    Moreira, Luis
    Goncalves, Helena M. R.
    Pereira, Leonor
    Castro, Claudia
    Jorge, Pedro
    Gouveia, Carlos
    Fernandes, Jose R.
    Martins-Lopes, Paula
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 234 : 92 - 97