Upon The Impact of Power System and Vacuum Circuit Breaker Parameters on Transient Recovery Voltage

被引:0
作者
Soloot, Amir Hayati [1 ]
Hoidalen, Hans Kristian [1 ]
机构
[1] Norwegian Univ Sci & Technol NTNU, Dept Elect Power Engn, N-7491 Trondheim, Norway
来源
2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC) | 2010年
关键词
Transient recovery voltage; vacuum circuit breaker; post arc current; current zero; ATP;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The aim of this paper is to investigate how Transient Recovery Voltage (TRV) characteristics are varied due to network and Vacuum Circuit Breaker (VCB) parameters. The role of RC damping branch to mitigate TRV is observed for Short Circuit (SC) and inductive load interruption. For this, a numerical method is taken to solve network and VCB equations simultaneously just after Current Zero (CZ). To evaluate numerical method, an analytical method base on step response of second order system is considered. The sensitivity of TRV amplitude to RC branch values is analytically discussed. As an internal VCB parameter, Post Arc Current (PAC) is considered and the effect of PAC on TRV after SC interruption is surveyed. Furthermore, the TRV computation method applied in this paper is evaluated with Alternative Transient Program (ATP) simulations.
引用
收藏
页数:4
相关论文
共 47 条
  • [1] Transient recovery voltage investigation on HV circuit breaker in hydro power plant
    Filipovic-Grcic, Bozidar
    Stipetic, Nina
    Vukovic, Franjo
    Jerkovic, Ante
    Sanic, Miso
    Musulin, Katarina
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 220
  • [2] Investigation on circuit breaker influence on transient recovery voltage
    Szewczyk, Marcin
    Kulas, Stanislaw
    2007 42ND INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, 2007, : 1036 - 1043
  • [3] Studies on the Influences of SFCL on the Transient Recovery Voltage of Circuit Breaker
    Li, Bin
    Ou, Yi Zhe
    2015 IEEE International Conference on Applied Superconductivity and Electromagnetic Devices (ASEMD), 2015, : 541 - 542
  • [4] Circuit Breaker Transient Recovery Voltage Requirements for Medium Voltage Systems with NRG
    Rifaat, Rasheek
    Lally, Tarjit Singh
    Hong, James
    2013 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, 2013,
  • [5] TESTS SHOW ABILITY OF VACUUM CIRCUIT-BREAKER TO INTERRUPT FAST TRANSIENT RECOVERY VOLTAGE RATES OF RISE OF TRANSFORMER SECONDARY FAULTS
    SMITH, RK
    IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (01) : 266 - 273
  • [6] Vacuum circuit breaker modelling for the assessment of transient recovery voltages: Application to various network configurations
    Bak, C. L.
    Borghetti, A.
    Glasdam, J.
    Hjerrild, J.
    Napolitano, F.
    Nucci, C. A.
    Paolone, M.
    ELECTRIC POWER SYSTEMS RESEARCH, 2018, 156 : 35 - 43
  • [7] Influence of system fault parameters on breaking performance of vacuum circuit breaker: modeling and simulation
    Shu, S. (shushengwen@whu.edu.cn), 1600, Electric Power Automation Equipment Press (33): : 81 - 87
  • [8] Recent development of high voltage circuit breaker for high voltage power transmission and distribution system
    Yanabu, S
    Zaima, E
    Hasegawa, T
    IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXHIBITION 2002: ASIA PACIFIC, VOLS 1-3, CONFERENCE PROCEEDINGS: NEW WAVE OF T&D TECHNOLOGY FROM ASIA PACIFIC, 2002, : 1438 - 1443
  • [9] A STATISTICAL VACUUM CIRCUIT-BREAKER MODEL FOR SIMULATION OF TRANSIENT OVERVOLTAGES
    KOSMAC, J
    ZUNKO, P
    IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (01) : 294 - 300
  • [10] Analysis of the Effect of a Saturable-Core HTS Fault Current Limiter on the Circuit Breaker Transient Recovery Voltage
    Lopez-Roldan, J.
    Price, A. C.
    De La Rosa, F.
    Moriconi, F.
    2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,