Effect of LigaSure™, Monopolar Cautery, and Bipolar Cautery on Surgical Margins in Breast-Conserving Surgery

被引:12
作者
Turkan, Ahmet [1 ]
Akkurt, Gokhan [2 ]
Yalaza, Metin [3 ]
Degirmencioglu, Gurkan [4 ]
Kafadar, Mehmet Tolga [5 ]
Yenidunya, Sibel [6 ]
Inan, Aydin [7 ]
Dener, Cenap [8 ]
机构
[1] Elbistan State Hosp, Clin Gen Surg, TR-46300 Kahramanmaras, Turkey
[2] Kecioren Training & Res Hosp, Dept Gen Surg, Ankara, Turkey
[3] Ankara Numune Training & Res Hosp, Div Surg Oncol, Dept Gen Surg, Ankara, Turkey
[4] Kirikhan State Hosp, Clin Gen Surg, Antakya, Turkey
[5] Mehmet Akif Inan Training & Res Hosp, Dept Gen Surg, Sanliurfa, Turkey
[6] Dr Abdurrahman Yurtaslan Ankara Res & Training Ho, Clin Pathol, Ankara, Turkey
[7] Umut Hosp, Clin Gen Surg, Ankara, Turkey
[8] Mem Hosp, Clin Gen Surg, Ankara, Turkey
关键词
Breast cancer; Lumpectomy; Breast-conserving surgery; Electrosurgery; Thermal destruction; LIGATION; CANCER; ELECTROSURGERY; SPREAD; CLIPS;
D O I
10.1159/000493985
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: We compared the differences in thermal damage at the surgical margin between monopolar cautery, bipolar cautery, and LigaSure (TM) in breast cancer lumpectomy specimens and assessed the effect of these techniques on the evaluation of the surgical margins. Methods: 30 patients scheduled for breast-conserving surgery for breast cancer were included in this study. During lumpectomy, each of the superior, inferior, lateral, and medial borders of the tumour was excised using one of the following: a scalpel, monopolar cautery, bipolar cautery, and LigaSure technology. The surgical margins of frozen and paraffin-embedded tissue sections of the lumpectomy specimen were evaluated. Thermal damage was defined as the maximum depth of thermal damage (in mm) from the surgical margin, and the level was categorized as none, low (<= 1 mm), or high (>1 mm). Results: There was no statistically significant difference between monopolar cautery, bipolar cautery, and LigaSure in terms of thermal damage. There was no thermal damage at the surgical margin in tissues dissected by scalpel. Conclusion: Thermal damage due to the excision method may cause false-negative and false-positive results in the surgical margin evaluation of lumpectomy specimens. More research is needed on the effects of different energy modalities on surgical margin evaluation in breast-conserving surgery.
引用
收藏
页码:194 / 199
页数:6
相关论文
共 19 条
[1]  
Amato B, 2012, MINERVA CHIR, V67, P445
[2]   Attaining Negative Margins in Breast-Conservation Operations: Is There a Consensus among Breast Surgeons? [J].
Blair, Sarah L. ;
Thompson, Kari ;
Rococco, Joseph ;
Malcarne, Vanessa ;
Beitsch, Peter D. ;
Ollila, David W. .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2009, 209 (05) :608-613
[3]  
Brzezinski Jan, 2011, Pol Przegl Chir, V83, P355, DOI 10.2478/v10035-011-0056-y
[4]  
Gaziolu E, 2013, TURKIYE KLIN J GEN S, V6, P52
[5]   Comparison of thermal spread after ureteral ligation with the Laparo-sonic™ ultrasonic shears and the Ligasure™ system [J].
Goldstein, SL ;
Harold, KL ;
Lentzner, A ;
Matthews, BD ;
Kercher, KW ;
Sing, RF ;
Pratt, B ;
Lipford, EH ;
Heniford, BT .
JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES-PART A, 2002, 12 (01) :61-63
[6]   Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries [J].
Harold, KL ;
Pollinger, H ;
Matthews, BD ;
Kercher, KW ;
Sing, RF ;
Heniford, BT .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2003, 17 (08) :1228-1230
[7]  
Harrell Andrew G, 2004, Semin Laparosc Surg, V11, P201, DOI 10.1177/107155170401100310
[8]   Lateral temperature spread of monopolar, bipolar and ultrasonic instruments for robot-assisted laparoscopic surgery [J].
Hefermehl, Lukas J. ;
Largo, Remo A. ;
Hermanns, Thomas ;
Poyet, Cedric ;
Sulser, Tullio ;
Eberli, Daniel .
BJU INTERNATIONAL, 2014, 114 (02) :245-252
[9]   Initial results with an electrothermal bipolar vessel sealer [J].
Heniford, BT ;
Matthews, BD ;
Sing, RF ;
Backus, C ;
Pratt, B ;
Greene, FL .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 2001, 15 (08) :799-801
[10]   Prospective Comparison of Four Laparoscopic Vessel Ligation Devices [J].
Lamberton, Gregory R. ;
Hsi, Ryan S. ;
Jin, Daniel H. ;
Lindler, Tekisha U. ;
Jellison, Forrest C. ;
Baldwin, D. Duane .
JOURNAL OF ENDOUROLOGY, 2008, 22 (10) :2307-2312