Evaluation of marginal fit of CAD/CAM restorations fabricated through cone beam computerized tomography and laboratory scanner data

被引:0
作者
Seker, Emre [1 ]
Ozcelik, Tuncer Burak [2 ]
Rathi, Nakul
Yilmaz, Burak [3 ]
机构
[1] Eskisehir Osmangazi Univ, Fac Dent, Dept Prosthodont, Eskisehir, Turkey
[2] Baskent Univ, Fac Dent, Dept Prosthodont, Adana, Turkey
[3] Ohio State Univ, Coll Dent, Div Restorat Sci & Prosthodont, Columbus, OH 43210 USA
关键词
ALL-CERAMIC CROWNS; CLINICAL-EVALUATION; LUTING AGENTS; ACCURACY; ADAPTATION; IMPRESSION; COPINGS; SYSTEM; DISCREPANCIES; PRECISION;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Whether cone beam computed tomography (CBCT) images can be used for the fabrication of computer-aided design/computer-aided manufacturing (CAD/CAM) restorations is unknown. Purpose. The purpose of this in vitro study was to evaluate the marginal fit of CAD/CAM restorations fabricated by using data from CBCT scans with 3 different voxels and laser scanner images. Material and methods. A crown preparation was made on an extracted premolar tooth according to ceramic crown preparation guidelines. The prepared tooth was scanned with a 3-dimensional (3D) extraoral laser scanner (D900; 3Shape), and CBCT scans were also made with an i-CAT cone beam 3D imaging system at 3 different voxel resolution settings: 0.125 mm, 0.20 mm, and 0.30 mm. The 3D images obtained from the laser scanner and CBCT scans were sent to CAD software, and a crown design was completed. Information was sent to CAM software to mill the crowns from poly(methyl methacrylate) (PMMA) blocks (n=9 from the laser scanner and 27 from 3 different CBCT scans). A total of 144 images (4 groups, 9 crowns per group, 4 sites per crown) were measured for vertical marginal discrepancy under a stereoscopic zoom microscope. One-way analysis of variance (ANOVA) was used to analyze the data. According to the assumption of homogeneity of variance, the post hoc Tukey multiple comparison test was performed (alpha=.05). Results. The marginal gap values of crowns fabricated with an extraoral laser scanner were significantly lower than those of crowns fabricated with 0.3-, 0.2-, and 0.125-voxel CBCT images (P<.001). The marginal gap was greater when 0.3- and 0.2-voxel CBCT images were used than when 0.125-voxel CBCT images were used (P<.001). Conclusions. Crowns fabricated with the laser scanner images had lower and clinically acceptable marginal discrepancies than crowns fabricated with CBCT images in 3 different voxels. Of all the CBCT scans, only images with 0.125 voxel produced crowns with clinically acceptable marginal discrepancy.
引用
收藏
页码:47 / 51
页数:5
相关论文
共 52 条
  • [1] Albert FE, 2004, INT J PROSTHODONT, V17, P529
  • [2] The Effect of Different Fabrication Steps on the Marginal Adaptation of Two Types of Glass-Infiltrated Ceramic Crown Copings Fabricated by CAD/CAM Technology
    Alghazzawi, Tariq F.
    Liu, Perng-Ru
    Essig, Milton E.
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2012, 21 (03): : 167 - 172
  • [3] EVALUATION OF THE MARGINAL FIT OF A ZIRCONIA CERAMIC COMPUTER-AIDED MACHINED (CAM) CROWN SYSTEM
    Baig, Mirza Rustum
    Tan, Keson Beng-Choon
    Nicholls, Jack I.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2010, 104 (04) : 216 - 227
  • [4] Benjamin Lewis S, 2002, J Oral Implantol, V28, P135, DOI 10.1563/1548-1336(2002)028<0135:TEOMDI>2.3.CO
  • [5] 2
  • [6] Digital dentistry: an overview of recent developments for CAD/CAM generated restorations
    Beuer, F.
    Schweiger, J.
    Edelhoff, D.
    [J]. BRITISH DENTAL JOURNAL, 2008, 204 (09) : 505 - 511
  • [7] Clinical fit of Procera AllCeram crowns
    Boening, KW
    Wolf, BH
    Schmidt, AE
    Kästner, K
    Walter, MH
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2000, 84 (04) : 419 - 424
  • [8] Adaptation of all-ceramic fixed partial dentures
    Borba, Marcia
    Cesar, Paulo F.
    Griggs, Jason A.
    Della Bona, Alvaro
    [J]. DENTAL MATERIALS, 2011, 27 (11) : 1119 - 1126
  • [9] THE EFFECTS OF DISPOSABLE AND CUSTOM-MADE IMPRESSION TRAYS ON THE ACCURACY OF IMPRESSIONS
    BURTON, JF
    HOOD, JAA
    PLUNKETT, DJ
    JOHNSON, SS
    [J]. JOURNAL OF DENTISTRY, 1989, 17 (03) : 121 - 123
  • [10] MEASUREMENT OF PAINT-ON DIE SPACERS USED FOR CASTING RELIEF
    CAMPAGNI, WV
    PRESTON, JD
    REISBICK, MH
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1982, 47 (06) : 606 - 611