共 50 条
MicroV Technology to Improve Transcranial Color Coded Doppler Examinations
被引:20
|作者:
Malferrari, Giovanni
[1
]
Pulito, Giuseppe
[2
,3
]
Pizzini, Attilia Maria
[4
]
Carraro, Nicola
[5
]
Meneghetti, Giorgio
[6
]
Sanzaro, Enzo
[7
]
Prati, Patrizio
[8
]
Siniscalchi, Antonio
[9
]
Monaco, Daniela
[10
]
机构:
[1] Azienda Unita Sanit Locale IRCCS, Neurol Unit, Stroke Unit, Reggio Emilia, RE, Italy
[2] Vito Fazzi Hosp, Dept Anaesthesia, Lecce, LE, Italy
[3] Vito Fazzi Hosp, Resuscitat Serv, Lecce, LE, Italy
[4] Maggiore Hosp, Dept Med, Bologna, BO, Italy
[5] Integrated Univ Healthcare Co, Dept Head & Neck, Neurol Clin, Trieste, TS, Italy
[6] Univ Padua, Sch Med, Dept Neurosci, Padua, PD, Italy
[7] Umberto I Hosp, Dept Med, Stroke Unit, Siracusa, SR, Italy
[8] CIDIMU, Neurol Unit, Turin, TO, Italy
[9] Annunziata Hosp, Dept Neurol, Cosenza, CS, Italy
[10] Spirito Santo Hosp, Dept Med, Stroke Unit, Pescara, PE, Italy
关键词:
MicroV;
transcranial color coded Doppler;
transcranial power Doppler;
morphological vessel resolution;
contrast enhancement;
POWER DOPPLER;
ISCHEMIC-STROKE;
ULTRASOUND;
SONOGRAPHY;
MANAGEMENT;
DIAGNOSIS;
PERFUSION;
THERAPY;
US;
D O I:
10.1111/jon.12517
中图分类号:
R74 [神经病学与精神病学];
学科分类号:
摘要:
The purpose of this review is to provide an update on technology related to Transcranial Color Coded Doppler Examinations. Microvascularization (MicroV) is an emerging Power Doppler technology which can allow visualization of low and weak blood flows even at high depths, thus providing a suitable technique for transcranial ultrasound analysis. With MicroV, reconstruction of the vessel shape can be improved, without any overestimation. Furthermore, by analyzing the Doppler signal, MicroV allows a global image of the Circle of Willis. Transcranial Doppler was originally developed for the velocimetric analysis of intracranial vessels, in particular to detect stenoses and the assessment of collateral circulation. Doppler velocimetric analysis was then compared to other neuroimaging techniques, thus providing a cut-off threshold. Transcranial Color Coded Doppler sonography allowed the characterization of vessel morphology. In both Color Doppler and Power Doppler, the signal overestimated the shape of the intracranial vessels, mostly in the presence of thin vessels and high depths of study. In further neurosonology technology development efforts, attempts have been made to address morphology issues and overcome technical limitations. The use of contrast agents has helped in this regard by introducing harmonics and subtraction software, which allowed better morphological studies of vessels, due to their increased signal-to-noise ratio. Having no limitations in the learning curve, in time and contrast agent techniques, and due to its high signal-to-noise ratio, MicroV has shown great potential to obtain the best morphological definition.
引用
收藏
页码:350 / 358
页数:9
相关论文