MicroV Technology to Improve Transcranial Color Coded Doppler Examinations

被引:20
|
作者
Malferrari, Giovanni [1 ]
Pulito, Giuseppe [2 ,3 ]
Pizzini, Attilia Maria [4 ]
Carraro, Nicola [5 ]
Meneghetti, Giorgio [6 ]
Sanzaro, Enzo [7 ]
Prati, Patrizio [8 ]
Siniscalchi, Antonio [9 ]
Monaco, Daniela [10 ]
机构
[1] Azienda Unita Sanit Locale IRCCS, Neurol Unit, Stroke Unit, Reggio Emilia, RE, Italy
[2] Vito Fazzi Hosp, Dept Anaesthesia, Lecce, LE, Italy
[3] Vito Fazzi Hosp, Resuscitat Serv, Lecce, LE, Italy
[4] Maggiore Hosp, Dept Med, Bologna, BO, Italy
[5] Integrated Univ Healthcare Co, Dept Head & Neck, Neurol Clin, Trieste, TS, Italy
[6] Univ Padua, Sch Med, Dept Neurosci, Padua, PD, Italy
[7] Umberto I Hosp, Dept Med, Stroke Unit, Siracusa, SR, Italy
[8] CIDIMU, Neurol Unit, Turin, TO, Italy
[9] Annunziata Hosp, Dept Neurol, Cosenza, CS, Italy
[10] Spirito Santo Hosp, Dept Med, Stroke Unit, Pescara, PE, Italy
关键词
MicroV; transcranial color coded Doppler; transcranial power Doppler; morphological vessel resolution; contrast enhancement; POWER DOPPLER; ISCHEMIC-STROKE; ULTRASOUND; SONOGRAPHY; MANAGEMENT; DIAGNOSIS; PERFUSION; THERAPY; US;
D O I
10.1111/jon.12517
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The purpose of this review is to provide an update on technology related to Transcranial Color Coded Doppler Examinations. Microvascularization (MicroV) is an emerging Power Doppler technology which can allow visualization of low and weak blood flows even at high depths, thus providing a suitable technique for transcranial ultrasound analysis. With MicroV, reconstruction of the vessel shape can be improved, without any overestimation. Furthermore, by analyzing the Doppler signal, MicroV allows a global image of the Circle of Willis. Transcranial Doppler was originally developed for the velocimetric analysis of intracranial vessels, in particular to detect stenoses and the assessment of collateral circulation. Doppler velocimetric analysis was then compared to other neuroimaging techniques, thus providing a cut-off threshold. Transcranial Color Coded Doppler sonography allowed the characterization of vessel morphology. In both Color Doppler and Power Doppler, the signal overestimated the shape of the intracranial vessels, mostly in the presence of thin vessels and high depths of study. In further neurosonology technology development efforts, attempts have been made to address morphology issues and overcome technical limitations. The use of contrast agents has helped in this regard by introducing harmonics and subtraction software, which allowed better morphological studies of vessels, due to their increased signal-to-noise ratio. Having no limitations in the learning curve, in time and contrast agent techniques, and due to its high signal-to-noise ratio, MicroV has shown great potential to obtain the best morphological definition.
引用
收藏
页码:350 / 358
页数:9
相关论文
共 50 条
  • [1] Comparison Between Transcranial Color-Coded Duplex Doppler and Contrast Enhanced Transcranial Color-Coded Duplex Doppler After Subarachnoid Aneurysmal Hemorrhage
    Rodrigues, Aurore
    Tarazona, Virginie
    Ladoux, Alexandre
    Leblanc, Pierre Etienne
    Harrois, Anatole
    Vigue, Bernard
    Duranteau, Jacques
    NEUROCRITICAL CARE, 2022, 36 (01) : 82 - 88
  • [2] Transcranial Doppler and Color-Coded Doppler Use for Brain Death Determination in Adult Patients: A Pictorial Essay
    Deana, Cristian
    Biasucci, Daniele G.
    Aspide, Raffaele
    Brasil, Sergio
    Vergano, Marco
    Leonardis, Francesca
    Rica, Ermal
    Cammarota, Gianmaria
    Dauri, Mario
    Vetrugno, Giuseppe
    Longhini, Federico
    Maggiore, Salvatore Maurizio
    Rasulo, Frank
    Vetrugno, Luigi
    JOURNAL OF ULTRASOUND IN MEDICINE, 2024, 43 (05) : 979 - 992
  • [3] A Comparative Study of Transcranial Color-Coded Doppler (TCCD) and Transcranial Doppler (TCD) Ultrasonography Techniques in Assessing the Intracranial Cerebral Arteries Haemodynamics
    Gunda, Simon Takadiyi
    Ng, Tsam Kit Veronica
    Liu, Tsz-Ying
    Chen, Ziman
    Han, Xinyang
    Chen, Xiangyan
    Pang, Marco Yiu-Chung
    Ying, Michael Tin-Cheung
    DIAGNOSTICS, 2024, 14 (04)
  • [4] Transcranial Doppler and color-coded duplex sonography: Established and new applications
    Baumgartner, RW
    Baumgartner, IB
    ULTRASCHALL IN DER MEDIZIN, 1996, 17 (02): : 50 - 54
  • [5] Contrast angiosonography: A technology to improve Doppler ultrasound examinations of the prostate
    Aarnink, RG
    Beerlage, HP
    de la Rosette, JJMCH
    Debruyne, FMJ
    Wijkstra, H
    EUROPEAN UROLOGY, 1999, 35 (01) : 9 - 20
  • [6] Point-of-care brain ultrasound and transcranial doppler or color-coded doppler in critically ill neonates and children
    Vinci, Francesco
    Tiseo, Marco
    Colosimo, Denise
    Calandrino, Andrea
    Ramenghi, Luca Antonio
    Biasucci, Daniele Guerino
    EUROPEAN JOURNAL OF PEDIATRICS, 2024, 183 (03) : 1059 - 1072
  • [7] Middle cerebral artery vasospasm: Transcranial color-coded duplex sonography versus conventional nonimaging transcranial Doppler sonography
    Swiat, Maciej
    Weigele, John
    Hurst, Robert W.
    Kasner, Scott E.
    Pawlak, Mikolaj
    Arkuszewski, Michal
    Al-Okaili, Riyadh N.
    Swiercz, Miroslaw
    Ustymowicz, Andrzej
    Opala, Grzegorz
    Melhem, Elias R.
    Krejza, Jaroslaw
    CRITICAL CARE MEDICINE, 2009, 37 (03) : 963 - 968
  • [8] Transcranial color-coded duplex sonography
    Ralf W. Baumgartner
    Journal of Neurology, 1999, 246 : 637 - 647
  • [9] TRANSCRANIAL COLOR-CODED SONOGRAPHY CRITERIA FOR MODERATE AND SEVERE MIDDLE CEREBRAL ARTERY STENOSIS
    Liu, Ran
    Li, Jingzhi
    Hua, Yang
    Yang, Jie
    Zhao, Yue
    Tian, Xiaojie
    Ma, Yan
    Zhao, Wenbo
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (01) : 25 - 32
  • [10] Competence for transcranial color-coded Duplex sonography is rapidly acquired
    Klinzing, S.
    Steiger, P.
    Schuepbach, R. A.
    Bechir, M.
    Brandi, G.
    MINERVA ANESTESIOLOGICA, 2015, 81 (03) : 298 - 304