Development and Characterization of A Linear Matrix-assisted Laser Desorption Ionization Mass Spectrometer

被引:7
|
作者
Yu Jia-Jun [1 ]
Liu Ping [3 ]
Zeng Zhen [1 ]
Chen Ying [1 ]
Gao Wei [1 ,2 ]
Li Mei [1 ,2 ]
Wang Chen-Guang [4 ]
Huang Zheng-Xu [1 ,2 ]
Zhou Zhen [1 ,2 ]
Li Lei [1 ,2 ]
机构
[1] Jinan Univ, Inst Mass Spectrometer & Atmospher Environm, Guangzhou 510632, Guangdong, Peoples R China
[2] Guangdong Prov Engn Res Ctr On Line Source Apport, Guangzhou 510632, Guangdong, Peoples R China
[3] Guangzhou HeXin Instrument Co LTD, Guangzhou 510530, Guangdong, Peoples R China
[4] Chinese Acad Sci, Guangzhou Inst Energy Convers, Guangzhou 510640, Guangdong, Peoples R China
关键词
Matrix-assisted laser desorption ionization; Linear time-of-flight mass spectrometer; Development; Performance characterization; MALDI-TOF MS; ESCHERICHIA-COLI; ION FORMATION; VITEK MS; TIME; IDENTIFICATION; BIOTYPER; EXTRACTION; RESOLUTION; PROTEINS;
D O I
10.1016/S1872-2040(17)61077-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) is an important analytical technique for biological macromolecules, such as proteins, peptides and nucleic acid, especially in the field of microbial identification. On the basis of previous study, a linear MALDI-TOF MS was been designed and assembled for biological applications. The instrument comprised a vacuum system, a vacuum fast sample introduction system, an optical system, a time-of-flight mass analyzer, an ion source, a data acquisition system and an electronic control system. The ion source adopted two-stage source acceleration, delayed extraction and dynamic pulse focusing technique. The time-of-flight distance of field-free drift region was about 1 m. The optical system adopted a solid-state laser with adjustable frequency of 1-2000 Hz and spots of 20-100 mu m. The angle of incidence laser was controlled at 5 degrees. A series of experiments were carried out to further evaluate the instrument performances. It could not only analyze the samples more than 199 kDa, but also achieve isotope resolution at 1000-3000 Da and up to 900 (FWHM) at 5000-17000 Da. The minimum detectable concentration of gramicidin was 10 amol mu L-1, absolute sensitivity reached up to 2.56 amol. Independent detection of saliva samples from different targets showed that the instrument had higher producibility. We identified Escherichia coli and Shigella spp., which are two common bacteria but difficult to be differentiated by mass spectrometry, showing its potential identification for clinical microorganism. In summary, this instrument can play a role on clinical examination in the near future.
引用
收藏
页码:463 / 470
页数:8
相关论文
共 28 条
  • [21] Comparison of Bruker Biotyper Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometer to BD Phoenix Automated Microbiology System for Identification of Gram-Negative Bacilli
    Saffert, Ryan T.
    Cunningham, Scott A.
    Ihde, Sherry M.
    Jobe, Kristine E. Monson
    Mandrekar, Jayawant
    Patel, Robin
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (03) : 887 - 892
  • [22] Mass spectrometry tools for the classification and identification of bacteria
    Sauer, Sascha
    Kliem, Magdalena
    [J]. NATURE REVIEWS MICROBIOLOGY, 2010, 8 (01) : 74 - 82
  • [23] FUNDAMENTAL-ASPECTS OF POSTSOURCE DECAY IN MATRIX-ASSISTED LASER DESORPTION MASS-SPECTROMETRY .1. RESIDUAL-GAS EFFECTS
    SPENGLER, B
    KIRSCH, D
    KAUFMANN, R
    [J]. JOURNAL OF PHYSICAL CHEMISTRY, 1992, 96 (24): : 9678 - 9684
  • [24] High performance MALDI-TOF mass spectrometry for proteomics
    Vestal, Marvin
    Hayden, Kevin
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2007, 268 (2-3) : 83 - 92
  • [25] Evolution of Quantitative MALDI-TOF Mass Spectrometry for Clinical Applications
    Vestal, Marvin L.
    [J]. CLINICAL CHEMISTRY, 2016, 62 (01) : 20 - 23
  • [26] The Future of Biological Mass Spectrometry
    Vestal, Marvin L.
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2011, 22 (06) : 953 - 959
  • [27] Comparison of Multiple Ionization Methods Coupled with Liquid Chromatography-Mass Spectrometry in Lipidomics Study of Serum Samples
    Wang Zhong-Hua
    Chen Yan-Hua
    Xu Jing
    Chen Hui-Li
    Zhou Xia
    Xiao Xin-Hua
    Ping Fan
    He Jiu-Ming
    Abliz Zeper
    Zhang Rui-Ping
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (05) : 674 - 680
  • [28] Rapid Microcystin Determination Using a Paper Spray Ionization Method with a Time-of-Flight Mass Spectrometry System
    Zhu, Xiaoqiang
    Huang, Zhengxu
    Gao, Wei
    Li, Xue
    Li, Lei
    Zhu, Hui
    Mo, Ting
    Huang, Bao
    Zhou, Zhen
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2016, 64 (27) : 5614 - 5619