Development and Characterization of A Linear Matrix-assisted Laser Desorption Ionization Mass Spectrometer

被引:7
|
作者
Yu Jia-Jun [1 ]
Liu Ping [3 ]
Zeng Zhen [1 ]
Chen Ying [1 ]
Gao Wei [1 ,2 ]
Li Mei [1 ,2 ]
Wang Chen-Guang [4 ]
Huang Zheng-Xu [1 ,2 ]
Zhou Zhen [1 ,2 ]
Li Lei [1 ,2 ]
机构
[1] Jinan Univ, Inst Mass Spectrometer & Atmospher Environm, Guangzhou 510632, Guangdong, Peoples R China
[2] Guangdong Prov Engn Res Ctr On Line Source Apport, Guangzhou 510632, Guangdong, Peoples R China
[3] Guangzhou HeXin Instrument Co LTD, Guangzhou 510530, Guangdong, Peoples R China
[4] Chinese Acad Sci, Guangzhou Inst Energy Convers, Guangzhou 510640, Guangdong, Peoples R China
关键词
Matrix-assisted laser desorption ionization; Linear time-of-flight mass spectrometer; Development; Performance characterization; MALDI-TOF MS; ESCHERICHIA-COLI; ION FORMATION; VITEK MS; TIME; IDENTIFICATION; BIOTYPER; EXTRACTION; RESOLUTION; PROTEINS;
D O I
10.1016/S1872-2040(17)61077-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) is an important analytical technique for biological macromolecules, such as proteins, peptides and nucleic acid, especially in the field of microbial identification. On the basis of previous study, a linear MALDI-TOF MS was been designed and assembled for biological applications. The instrument comprised a vacuum system, a vacuum fast sample introduction system, an optical system, a time-of-flight mass analyzer, an ion source, a data acquisition system and an electronic control system. The ion source adopted two-stage source acceleration, delayed extraction and dynamic pulse focusing technique. The time-of-flight distance of field-free drift region was about 1 m. The optical system adopted a solid-state laser with adjustable frequency of 1-2000 Hz and spots of 20-100 mu m. The angle of incidence laser was controlled at 5 degrees. A series of experiments were carried out to further evaluate the instrument performances. It could not only analyze the samples more than 199 kDa, but also achieve isotope resolution at 1000-3000 Da and up to 900 (FWHM) at 5000-17000 Da. The minimum detectable concentration of gramicidin was 10 amol mu L-1, absolute sensitivity reached up to 2.56 amol. Independent detection of saliva samples from different targets showed that the instrument had higher producibility. We identified Escherichia coli and Shigella spp., which are two common bacteria but difficult to be differentiated by mass spectrometry, showing its potential identification for clinical microorganism. In summary, this instrument can play a role on clinical examination in the near future.
引用
收藏
页码:463 / 470
页数:8
相关论文
共 28 条
  • [1] INFLUENCE OF THE LASER-BEAM DIRECTION ON THE MOLECULAR ION EJECTION ANGLE IN MATRIX-ASSISTED LASER-DESORPTION IONIZATION
    AKSOUH, F
    CHAURAND, P
    DEPRUN, C
    DELLANEGRA, S
    HOYES, J
    LEBEYEC, Y
    PINHO, RR
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (06) : 515 - 518
  • [2] Observation of Escherichia coli ribosomal proteins and their posttranslational modifications by mass spectrometry
    Arnold, RJ
    Reilly, JP
    [J]. ANALYTICAL BIOCHEMISTRY, 1999, 269 (01) : 105 - 112
  • [3] Comprehensive glycosylation profiling of IgG and IgG-fusion proteins by top-down MS with multiple fragmentation techniques
    Bao Quoc Tran
    Barton, Christopher
    Feng, Jinhua
    Sandjong, Aimee
    Yoon, Sung Hwan
    Awasthi, Shivangi
    Liang, Tao
    Khan, Mohd M.
    Kilgour, David P. A.
    Goodlett, David R.
    Goo, Young Ah
    [J]. JOURNAL OF PROTEOMICS, 2016, 134 : 93 - 101
  • [4] DYNAMICAL PARAMETERS OF ION EJECTION AND ION FORMATION IN MATRIX-ASSISTED LASER DESORPTION/IONIZATION
    BOKELMANN, V
    SPENGLER, B
    KAUFMANN, R
    [J]. EUROPEAN MASS SPECTROMETRY, 1995, 1 (01): : 81 - 93
  • [5] MASS RESOLUTION IMPROVEMENT BY INCORPORATION OF PULSED ION EXTRACTION IN A MATRIX-ASSISTED LASER-DESORPTION IONIZATION LINEAR TIME-OF-FLIGHT MASS-SPECTROMETER
    BROWN, RS
    LENNON, JJ
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (13) : 1998 - 2003
  • [6] Identification of Clinical Isolates of α-Hemolytic Streptococci by 16S rRNA Gene Sequencing, Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry Using MALDI Biotyper, and Conventional Phenotypic Methods: a Comparison
    Davies, Angharad Puw
    Reid, Michelle
    Hadfield, Stephen J.
    Johnston, Stuart
    Mikhail, Jane
    Harris, Llinos G.
    Jenkinson, Howard F.
    Berry, Nidhika
    Lewis, Ann M.
    El-Bouri, Khalid
    Mack, Dietrich
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2012, 50 (12) : 4087 - 4090
  • [7] ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES
    FENN, JB
    MANN, M
    MENG, CK
    WONG, SF
    WHITEHOUSE, CM
    [J]. SCIENCE, 1989, 246 (4926) : 64 - 71
  • [8] Characterization of intact microorganisms by MALDI mass spectrometry
    Fenselau, C
    Demirev, PA
    [J]. MASS SPECTROMETRY REVIEWS, 2001, 20 (04) : 157 - 171
  • [9] Comparison of Vitek MS and MALDI Biotyper for Identification of Actinomycetaceae of Clinical Importance
    Ferrand, Janina
    Hochard, Helene
    Girard, Victoria
    Aissa, Nejla
    Bogard, Baptiste
    Alauzet, Corentine
    Lozniewski, Alain
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2016, 54 (03) : 782 - 784
  • [10] Improved resolution for MALDI-TOF mass spectrometers: a mathematical study
    Franzen, J
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1997, 164 (1-2): : 19 - 34